The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Robot-assisted movement training compared with conventional therapy techniques for the rehabilitation of upper-limb motor function after stroke
Abstract
Objective To compare the effects of robot-assisted movement training with conventional techniques for the rehabilitation of upper-limb motor function after stroke.Design Randomized controlled trial, 6-month follow-up.Setting A Department of Veterans Affairs rehabilitation research and development center.Participants Consecutive sample of 27 subjects with chronic hemiparesis (>6mo after cerebrovascular accident) randomly allocated to group.Interventions All subjects received twenty-four 1-hour sessions over 2 months. Subjects in the robot group practiced shoulder and elbow movements while assisted by a robot manipulator. Subjects in the control group received neurodevelopmental therapy (targeting proximal upper limb function) and 5 minutes of exposure to the robot in each session.Main outcome measures Fugl-Meyer assessment of motor impairment, FIMtrade mark instrument, and biomechanic measures of strength and reaching kinematics. Clinical evaluations were performed by a therapist blinded to group assignments.Results Compared with the control group, the robot group had larger improvements in the proximal movement portion of the Fugl-Meyer test after 1 month of treatment (P<.05) and also after 2 months of treatment (P<.05). The robot group had larger gains in strength (P<.02) and larger increases in reach extent (P<.01) after 2 months of treatment. At the 6-month follow-up, the groups no longer differed in terms of the Fugl-Meyer test (P>.30); however, the robot group had larger improvements in the FIM (P<.04).Conclusions Compared with conventional treatment, robot-assisted movements had advantages in terms of clinical and biomechanical measures. Further research into the use of robotic manipulation for motor rehabilitation is justified.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Nonparametric Statistics for the Behavioral Sciences
Guitton, H., & Siegel, S. (1958) · Revue économique · doi:10.2307/3498751 · Cited by 35,279
Nonparametric Statistics for the Behavioral Sciences.
Whitfield, J. W., & Siegel, S. (1957) · Journal of the Royal Statistical Society Series A (General) · doi:10.2307/2342828 · Cited by 8,017
Analysis of Incomplete Multivariate Data
Booth, D. E., & Schafer, J. L. (2000) · Technometrics · doi:10.2307/1271466 · Cited by 5,627
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Understanding motor events: a neurophysiological study
di Pellegrino, G., Fadiga, L., Fogassi, L., Gallese, V., & Rizzolatti, G. (1992) · Experimental Brain Research · doi:10.1007/bf00230027 · Cited by 3,539
Nonparametric Statistics : for the Behavioral Sciences
Siegel, S. (1956) · UCLA - Biblioteca de Ciencias y Tecnologia Felix Morales Bueno · Cited by 3,314
Nudo, R. J., Wise, B. M., SiFuentes, F., & Milliken, G. W. (1996) · Science · doi:10.1126/science.272.5269.1791 · Cited by 1,911
The Barthel ADL Index: A standard measure of physical disability?
Wade, D. T., & Collin, C. (1988) · International Disability Studies · doi:10.3109/09638288809164105 · Cited by 1,587
Technique to improve chronic motor deficit after stroke.
Taub, E., Miller, N. E., Novack, T. A., Cook, E. W., Fleming, W. C., Nepomuceno, C., Connell, J., & Crago, J. E. (1993) · PubMed · Cited by 1,557
Treatment-Induced Cortical Reorganization After Stroke in Humans
Liepert, J., Bauder, H., Miltner, W. H. R., Taub, E., & Weiller, C. (2000) · Stroke · doi:10.1161/01.str.31.6.1210 · Cited by 1,406
Flagged first, then by citations
Research works printed but not linked: 1
- Burgar, 1999, Rehabilitation of upper limb dysfunction in chronic hemiplegia: robot-assisted movements vs. conventional therapy [abstract], Arch Phys Med Rehabil, 80, 1121
Cited by
Sorted by citations
Items 901–1,000 of 1,000
A robotic arm design for stroke patients
Wang, S., Cheng, K. W. E., Ding, K., Lin, J., & Xu, C. (2009) · PolyU Institutional Research Archive (Hong Kong Polytechnic University) · Cited by 2
Analysis of the Body Control System Related to Mental Workload
Naito, S., Kim, Y., & Obinata, G. (2012) · International Journal of Advanced Robotic Systems · doi:10.5772/52249 · Cited by 2
“[8][34][36] showed that robot‐aided rehabilitation has many advantages over conventional therapist‐based rehabilitation methods in terms of the recovery of motor function, physical balance support in specific tasks through reinforcement learning, patient‐ centred rehabilitation process and the enlargement of joint ran…”
BackgroundWagner, S. (2014) · Cited by 2
Modeling and taylormade training method using neural network for specific muscle of the upper limb
Terashima, K., Miyoshi, T., Itokazu, K., Ueno, Y., & Watanabe, D. (2014) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.1109/iccas.2014.6987881 · Cited by 2
“indicated that, compared with conventional therapy techniques, robot-assisted training is more efficient for improving muscle strength and path-following capabil ity [1].”
ResultInfluentialNew Therapeutic Approaches in upper Extremity Rehabilitation
Kim, M. W. (2008) · Brain & Neurorehabilitation · doi:10.12786/bn.2008.1.1.20 · Cited by 2
Post-stroke Motor Rehabilitation
Wang, J., & Jin, K. (2017) · Translational medicine research · doi:10.1007/978-981-10-5804-2_24 · Cited by 2
An AR system to motivate the trainer during the robot-assisted rehabilitation
Liu, Y., Sun, R., & Zhang, F. (2017) · IEEE Conference on Cybernetics and Intelligent Systems · doi:10.1109/iccis.2017.8274768 · Cited by 2
Tseng, K. C., Wong, M., Wu, C.-Y., Chang, T., Pei, Y., & Chen, J. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-92052-8_30 · Cited by 2
A Bilateral Training System for Upper-limb Rehabilitation: A Follow-up Study
Sheng, B., Zhang, Y., Tang, L., Xie, S. Q., & Deng, C. (2018) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2018.8452419 · Cited by 2
“Compared to the traditional manual therapy, the robot involved therapy can alleviate labor-intensive aspects of conventional rehabilitation trainings, and provide precise passive/active repetitive trainings in a sufficiently long timeframe [1, 2].”
BackgroundHuman-Machine Interfaces for Robotic System Control
Roibu, H., Popescu, D., Abagiu, M. M., & Bîzdoacă, N. G. (2018) · International Conference on Applied and Theoretical Electricity · doi:10.1109/icate.2018.8551362 · Cited by 2
“In addition to the use of classical recovery techniques, there is a growing trend in the use of robotic systems for medical recovery of all upper limb or for some parts of it [10-20].”
BackgroundComputerized Adaptive Testing System of Functional Assessment of Stroke
Lin, G., Huang, Y., Chou, Y.-T., Chiang, H.-Y. A., & Hsieh, C. (2019) · Journal of Visualized Experiments · doi:10.3791/58137 · Cited by 2
Desplenter, T., Chinchalkar, S. J., & Trejos, A. L. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779528 · Cited by 2
“[7]–[9].”
Proof of Concept: Using Reinforcement Learning agent as an adversary in Serious Games
Hornak, D., Jaščur, M., Ferenčík, N., & Bundzel, M. (2019) · IEEE International Work Conference on Bioinspired Intelligence (IWOBI) · doi:10.1109/iwobi47054.2019.9114431 · Cited by 2
Sampling Electrocardiography Confirmation for a Virtual Reality Pain Management Tool
Matsangidou, M., Mauger, A. R., Ang, C. S., & Pattichis, C. S. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-49698-2_27 · Cited by 2
Dewald, J. P. A., Ellis, M. D., Acosta, A. M., McPherson, J. G., & Stienen, A. H. A. (2016) · Springer eBooks · doi:10.1007/978-3-319-28603-7_18 · Cited by 2
Feature Selection Using EEG Signals: A Novel Hybrid Binary Particle Swarm Optimization
Nemati, M., Taheri, A., Ghazizadeh, A., Dehkordi, M. B., & Meghdari, A. F. (2022) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom57054.2022.10025190 · Cited by 3
“Figure 1 shows some application areas of HRI in real-life situations with two examples each [1], [2], [11]–[13], [3]– [10].”
BackgroundForecasting Bimanual Object Manipulation Sequences from Unimanual Observations
Razali, H., & Demiris, Y. (2024) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v38i5.28266 · Cited by 2
“Being able to forecast the movement of both hands as one reaches a fork and another a spoon is useful as it opens up additional use cases such as occlusion handling or vision-based rehabilitative robots (Lum et al. 2002).”
BackgroundNuevas tecnologías en neurorrehabilitación aplicadas al tratamiento del paciente con lesión medular
Agudo, Á. M. G. (2019) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2019.03.024 · Cited by 3
Pascal, M. R., & Barker, S. P. (2014) · Elsevier eBooks · doi:10.1016/b978-0-7020-4588-2.00027-9 · Cited by 2
Classification examples for healthcare
Subaşı, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-821379-7.00004-7 · Cited by 2
Subaşı, A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817444-9.00001-5 · Cited by 2
Sivan, M. (2014) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 2
Emerging Technology Briefing Paper on the Use of Robots in Surgery
Sutcliffe, P., Czoski‐Murray, C., Chattle, M., Ayiku, L., & Parry, G. (2006) · Cited by 2
Design and control of active knee rehabilitation orthotic device (AKROD)
Jain, V. K. (2009) · doi:10.17760/d20000031 · Cited by 2
Nunes, W. M. (2012) · Cited by 2
Pehlivan, A. U. (2012) · Rice Research Repository (Rice University) · Cited by 2
Design of an Adaptive System for Upper-limb Stroke Rehabilitation
Kan, P. (2009) · TSpace (University of Toronto) · Cited by 2
Design and development of a robotic glove for hand rehabilitation
Biggar, S. (2016) · STAX · doi:10.48730/qrxk-e149 · Cited by 2
Farjadian, A. B. (2015) · doi:10.17760/d20193790 · Cited by 2
Feng, T., Xu, G., Guo, Y., Gao, X., Li, H., & Liang, Z. (2012) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2012.6491317 · Cited by 1
“that would teach the patient various physical exercises [2].”
BackgroundSelecting Muscles for Detection of Upper-Limb Compensatory Movements Using s-EMG Sensors
Berjis, M., LeBel, M., Lizotte, D. J., & Trejos, A. L. (2025) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2025.3531015 · Cited by 1
“Rehabilitation using wearable technology has proven to be an effective recovery method [4].”
Dynamic Modeling and Simulation Analysis of an Arm Rehabilitation Robot With Mobile Platform
Gong, T., Lin, Y., Wang, Y., Wang, W., Chen, W., & Ji, J. (2025) · Applied Bionics and Biomechanics · doi:10.1155/abb/8254911 · Cited by 1
“Furthermore, Lum et al. [23] compared the robot-assisted training with the conventional therapy techniques for the upper-limb motor function rehab, and the literatures proposed the important robot-assisted and the EMG arm training methods for upper-limb motor function rehab, which promoted the…”
Wongwatcharanon, T., Tantilipikorn, P., Rungroungdouyboon, B., & Kooncumchoo, P. (2025) · Life · doi:10.3390/life15070994 · Cited by 1
Robot-Assisted Upper Limb Rehabilitation System Based on Variable Admittance Control
Colasanto, D., Secciani, N., Bucci, A., Topini, A., Ridolfi, A., & Allotta, B. (2025) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms65348.2025.00123 · Cited by 1
Akpulat, H. M. G., & Avcı, Ş. (2025) · Journal of Exercise Therapy and Rehabilitation · doi:10.15437/jetr.1432655 · Cited by 1
Avcı, C., Öneş, K., & Yıldırım, M. A. (2025) · Kahramanmaraş Sütçü İmam Üniversitesi Tıp Fakültesi Dergisi · doi:10.17517/ksutfd.1626261 · Cited by 1
End-Effector-Based Robots for Post-Stroke Rehabilitation of Proximal Arm Joints: A Literature Review
Moayer, S., Alqasemi, R. M., & Dubey, R. (2026) · Robotics · doi:10.3390/robotics15010020 · Cited by 1
Evaluation of s-EMG Sensor Locations for Upper-Limb Compensatory Movement Detection
Berjis, M., LeBel, M., Lizotte, D. J., & Trejos, A. L. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3663991 · Cited by 1
“Wearable mechatronic devices help patients to adhere to physical therapy, receive longer and more frequent sessions, and obtain quantitative feedback on their improvement [5], [6].”
Reinkensmeyer, D. J. (2026) · Neurorehabilitation and neural repair · doi:10.1177/15459683261448473 · Cited by 1
“…produced a bimanual after effect, 14 and, together with my lab mate Pete Lum – who later went on to make important contributions to rehabilitation robotics including building a system to automate CIMT 15-17 – we decided to build robotic devices for bimanual movement training 4,18 (Figure 1(B)).”
Santoriello, V., Cesarelli, G., Ficuciello, F., Giugliano, C., Angelone, F., Russo, M., Ponsiglione, A. M., & Romano, M. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae7862 · Cited by 1
Aramaki, S., SAYAMA, I., NAKAZAWA, M., Yokoyama, E., Shimomura, T., & HOSOKAWA, K. (2011) · リハビリテーション医学 : 日本リハビリテーション医学会誌 · doi:10.2490/jjrmc.48.612 · Cited by 1
Comparison of Tone compensation and Spring assistance for hand rehabilitation in HEXORR
Godfrey, S. B., Holley, R. J., & Lum, P. S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6092106 · Cited by 1
“The advent of rehabilitation robotics has enabled increased repetition while lessening the burden to the therapist and achieving comparable results to conventional therapy [3-4].”
ResultApplication of dynamics parameter identification of limb for rehabilitation robot
Guo, X., & Yan, Y. (2010) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2010.5640004 · Cited by 1
“The rehabilitation robotics [1] has recently been a new developing technology on motor nerve rehabilitation.”
BackgroundZhou, L., Ang, K. K., Wang, C., Phua, K. S., & Guan, C. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696171 · Cited by 1
Robotic Assistance for Cerebellar Reaching
Grow, D., Bastian, A. J., & Okamura, A. M. (2014) · Trends in augmentation of human performance · doi:10.1007/978-94-017-8932-5_12 · Cited by 1
Modeling and Verification of a Bimanual-Coordinated Training System
Li, C., INOUE, Y., Liu, T., SHIBATA, K., & Sun, L. (2011) · Advanced Robotics · doi:10.1163/016918611x588880 · Cited by 1
“MIME [3, 4] can support bilateral training with the movement of the healthy limb as a reference for the impaired one.”
BackgroundInfluentialOhura, T., Nishiyama, C., & Nakayama, T. (2009) · Asian Journal of Occupational Therapy · doi:10.11596/asiajot.7.13 · Cited by 1
Pernalete, N., Raheja, A., & Knaack, A. (2015) · International Conference on PErvasive Technologies Related to Assistive Environments (PETRA) · doi:10.1145/2769493.2769591 · Cited by 1
Home based therapy can be of, at least, short term value
Wolf, S. L. (2011) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2011.18.2.116 · Cited by 1
Simkins, M., Roldan, J. R., Kim, H., Abrams, G., Byl, N. N., & Rosén, J. (2013) · doi:10.1115/dscc2013-4042 · Cited by 1
“This seemingly unusual finding is explainable in part by the involuntary joint synergies that are characteristic of paretic arms [17].”
BackgroundEng, D. P., Kadivar, Z., Sullivan, J. L., Pehlivan, A. U., O’Malley, M. K., Francisco, G. E., & Yozbatıran, N. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6095134 · Cited by 1
“Early examples of these robots include the MIT-MANUS [11] and MIME [12, 13].”
MethodDewald, J. P. A., Ellis, M. D., Acosta, A. M., McPherson, J. G., & Stienen, A. H. A. (2011) · Springer eBooks · doi:10.1007/978-1-4471-2277-7_19 · Cited by 1
Enhancements to the Planar Active Handrest
Fehlberg, M. A., Sani, H. N., & Provancher, W. R. (2015) · Journal of Human-Robot Interaction · doi:10.5898/jhri.4.3.fehlberg · Cited by 1
“Endpoint manipulation rehabilitation devices guide a user’s hand along a predefined trajectory to regain lost motor skills in their arm (Hogan, Krebs, Sharon, & Charnnarong, 1995; Loureiro, Amirabdollahian, Topping, Driessen, & Harwin, 2003; Lum & Burgar, 2002).”
BackgroundElnady, A. M., Mohamadzadeh, S., Jiang, X., & Menon, C. (2016) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2016.7726667 · Cited by 1
“Also robot assisted movements had advantages over conventional therapy in terms of clinical and biomechanical measures [3][4].”
BackgroundHARAGUCHI, M., Kikuchi, T., Mihara, M., Hatakenaka, M., Miyai, I., & FURUSHO, J. (2010) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.76.942 · Cited by 1
Castaño, C. Y. M., Peñaranda, Y. L. P., Bernal, M. Y. P., & Ruíz, J. C. (2017) · Fisioterapia · doi:10.1016/j.ft.2017.08.001 · Cited by 1
Design, Development and Evaluation of an Experimental Protocol to User Acceptance of WRs
Flores-Ragoitia, J. M., Izquierdo-Reyes, J., Rovira, J. L. P., & Bustamante-Bello, R. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01845-0_81 · Cited by 1
Design and Evaluation of a Multi-Mode Robotic Arm Orthosis using Musculoskeletal Simulation
Ödemiş, E., & Baysal, C. V. (2018) · Çukurova Üniversitesi Mühendislik Fakültesi Dergisi · doi:10.21605/cukurovaummfd.504557 · Cited by 1
Sun, C., Wang, Z., Wang, X., Liu, Y., Hu, B., Guo, Z., Cong, Z., Yan, Z., & Jiang, S. (2021) · IEEE International Conference on Electronic Technology, Communication and Information (ICETCI) · doi:10.1109/icetci53161.2021.9563349 · Cited by 1
Focus on Patient in Virtual Reality-Assisted Rehabilitation
Mottura, S., Fontana, L., Arlati, S., Redaelli, C., Zangiacomi, A., & Sacco, M. (2018) · IGI Global eBooks · doi:10.4018/978-1-5225-5469-1.ch068 · Cited by 1
Greenhalgh, M., Duvall, J. A., Candiotti, J. L., Chung, C. S., Jorgensen-Wagers, K., Smolinksi, G., Peterson, S., Schneider, U., Cooper, R., & Cooper, R. A. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_47-1 · Cited by 1
Bao, S., Lei, Y., Keenan, K. G., & Wang, J. (2022) · Human Movement Science · doi:10.1016/j.humov.2022.103017 · Cited by 1
Upper-Extremity Movement Training with Mechanically Assistive Devices
Reinkensmeyer, D. J., Zondervan, D. K., & Comellas, M. (2022) · Springer eBooks · doi:10.1007/978-3-031-08995-4_28 · Cited by 2
Design and simulation of an upper limb rehabilitation exoskeleton robot
Hou, H., & Jiang, Z. (2022) · International Conference on Control and Intelligent Robotics (ICCIR) · doi:10.1145/3548608.3559175 · Cited by 1
“Based on conventional treatment, both robot-assisted training and conventional occupational therapy can improve the motor function and activity ability of the upper limb of hemiplegic patients, and the former is better than conventional occupational therapy in promoting motor function recovery [4].”
BackgroundIs a robot needed to modify human effort in bimanual tracking?
Perez, N. P., Eden, J., Ivanova, E., Burdet, E., & Farkhatdinov, I. (2022) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob52689.2022.9925446 · Cited by 1
“Some devices like the MIME [3] offer self training modes where hemiplegic patients can guide their affected arm through the mirrored motions of their non-affected.”
BackgroundWolbrecht, E. T., Ketkar, V. D., & Perry, J. C. (2023) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr58425.2023.10304762 · Cited by 1
“Research has demonstrated the efficacy of robot-assisted therapy in improving motor functioning in survivors of stroke [4], [5].”
BackgroundDesign, Manufacturing and Testing of ARMS: A Modular and Portable Upper Limb Rehabilitation Robot
Siciliano, A. A., Dib, A. E. H., Luna, F. D. L., Moura, R. T., & Forner‐Cordero, A. (2024) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob60516.2024.10719715 · Cited by 1
“Robotic rehabilitation is one of them, which has been present since the 1990’s with systems such as the MIT-MANUS [5], ARMEO [6], MIME [7] and GENTLE/S [8].”
MethodAnalysis of reaching movements of upper arm in robot assisted exercises
Iuppariello, L., D’Addio, G., Romano, M., Bifulco, P., Lanzillo, B., Pappone, N., & Cesarelli, M. (2025) · Giornale italiano di medicina del lavoro ed ergonomia · doi:10.4081/gimle.660 · Cited by 1
Robotic rehabilitation of stroke patients using an expert system
Natarajan, P., Agah, A., & Liu, W. M. E. (2011) · Journal of Automation Mobile Robotics & Intelligent Systems · Cited by 1
Preliminary investigation into the effects of visual feedback distortion on range of motion
Supple, K. A., & Brewer, B. R. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091664 · Cited by 1
A novel PNF-based rehabilitation robot for upper-limb of stroke patients
Chao, L., Xie, L., Cai, B., & Wang, J. (2010) · International Convention on Rehabilitation Engineering & Assistive Technology · Cited by 1
Ma, Y., Xie, S. Q., & Zhang, Y. (2016) · Advanced Robotics · doi:10.1080/01691864.2016.1175382 · Cited by 1
Straudi, S., Chew, E., Cajigas, I., Fregni, F., & Bonato, P. (2016) · Clinical Case Reports and Reviews · doi:10.15761/ccrr.1000196 · Cited by 1
Intelligent Control of Robot Manipulator
Yang, C., Ma, H., & Fu, M. (2016) · Springer eBooks · doi:10.1007/978-981-10-0830-6_3 · Cited by 1
Saha, D. S. (2016) · Journal of Medical Science And clinical Research · doi:10.18535/jmscr/v4i11.78 · Cited by 1
“(2-4) Most of them havecompared similar duration of robotic and conventional therapy and have found Robotic therapy to be more effective.”
BackgroundBehavioral Archetypes for Stroke Rehabilitation Technologies
Alkadhi, B., & Al‐Wabil, A. (2018) · Communications in computer and information science · doi:10.1007/978-3-319-92279-9_2 · Cited by 1
Functional Testing Procedures and Results for a Rehabilitation Robotic System
Popescu, D., Roibu, H., Copilusi, C. P., Rusu, L., Avramescu, T. E., Zăvăleanu, M., Popescu, L. C., & Marin, M. I. (2018) · International Conference and Exposition on Electrical and Power Engineering (EPE) · doi:10.1109/icepe.2018.8559676 · Cited by 1
“In addition to the use of classical recovery techniques, there is a growing trend in the use of robotic systems for medical recovery of whole upper limb or for some parts of it (shoulder, elbow, wrist, arm, forearm, hand) [1-10].”
Background[Study on the center-driven multiple degrees of freedom upper limb rehabilitation training robot].
Huang, X., Yu, H., Wang, J., Dong, Q., Zhang, L., Meng, Q., Li, S., & Wang, D. (2018) · PubMed Central · doi:10.7507/1001-5515.201703052 · Cited by 1
Haptic Device with Decoupled Motion for Rehabilitation and Training of the Upper Limb
Antonya, C., Butnariu, S., & Pozna, C. R. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-16681-6_41 · Cited by 1
Robotic Care: A Low Cost Design to Assist Therapy for Brain Stroke Rehabilitation
Prieto, P. A., Cheein, F. A., Escobar, M., Vallejos, R. O., Maldonado, P., Larrain, C., & Serey, M. (2019) · Proceedings of the ... International Conference on Engineering Design · doi:10.1017/dsi.2019.103 · Cited by 1
Manipulator for upper limbs rehabilitation-ROBCO ®
Chivarov, N., & Chikurtev, D. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/878/1/012004 · Cited by 1
DESIGN AND MYOELECTRIC CONTROL OF AN ACTIVE ORTHOSIS DEVICE USING FINITE STATE MACHINE ALGORITHM
Ülkir, O., Akgün, G., Toptaş, E., & Kaplanoğlu, E. (2020) · Technium Romanian Journal of Applied Sciences and Technology · doi:10.47577/technium.v2i7.2122 · Cited by 1
“The other method is External Active Orthoses (EAO), where the support and power, necessary for the system, are provided by actuators (Lum et al., 2002).”
MethodJunior, A. G. L., & Frizera, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-32-385952-3.00010-x · Cited by 1
Nunes, P. F., Mosconi, D., Ostan, Í., & Siqueira, A. A. G. (2022) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-70601-2_96 · Cited by 1
Upper and lower limb linkage design and training trajectory planning of rehabilitation robot
Yuan, J., Zheng, Z., Bao, S., Du, L., & Zhou, T. (2022) · IEEE International Conference on Real-time Computing and Robotics (RCAR) · doi:10.1109/rcar54675.2022.9872195 · Cited by 1
“Especially in today's accelerated aging, more and more elderly people lose their lives due to stroke [2,3].”
BackgroundLower Limb Motor Coordination and Rehabilitation Facilitated through Self- Assist.
Danek, K. A. (2008) · Deep Blue (University of Michigan) · Cited by 1
Automatisierte motorische Rehabilitation
Hesse, S., & Werner, C. (2010) · Springer eBooks · doi:10.1007/978-3-642-12915-5_17 · Cited by 1
Zerebral bedingte Paresen und Spastik
Freivogel, S. (2006) · Nervenheilkunde · doi:10.1055/s-0038-1626456 · Cited by 1
A Numerical Approach for Modeling the Human Upper Limb
Grecu, V., Dumitru, N., & Grecu, L. (2009) · Cited by 1
Exploring upper limb interventions after stroke
Coupar, F. (2012) · Enlighten: Theses (The University of Glasgow) · Cited by 1
Management of Physical Impairments Post‐Stroke
Kilbride, C., & Kneafsey, R. (2010) · Wiley eBooks · doi:10.1002/9781444318838.ch7 · Cited by 1
Pérez‐Rodríguez, R. (2012) · doi:10.20868/upm.thesis.14737 · Cited by 1
Development of a Systems Architecture for Robot-Aided Telerehabilitation
Colombo, R., Pisano, F., Mazzone, A., Delconte, C., & Minuco, G. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428412 · Cited by 1
“The systems architecture implemented consists of three rehabilitation stations and a supervision workstation, located in different laboratories, and interconnected by means of a standard Ethernet II network.”
MethodLEIFER, L. J., Wagner, J. J., Johnson, M. J., & der Loos, H. F. M. V. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1053317 · Cited by 1
Matsuoka, Y., Brewer, B. R., & Klatzky, R. L. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404346 · Cited by 1
“So far, virtual and robotic rehab environments have focused on increasing strength and range of motion [1-5].”
BackgroundMarchal–Crespo, L. (2009) · Bern Open Repository and Information System (University of Bern) · doi:10.7892/boris.117120 · Cited by 1
Pattern recognition of surface electromyography signals for real-time control of wrist exoskeletons
Khokhar, Z. O. (2010) · Summit (Simon Fraser University) · Cited by 1
Design and control of robotic systems for upper extremity rehabilitation following stroke
Wang, F. (2011) · Cited by 1
van Asseldonk, E. H. F. (2008) · doi:10.3990/1.9789036526401 · Cited by 1
Metadata
- Authors
- Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M.
- Affiliations
- Virginia Commonwealth University (US)
- ORCID
- Lum, Peter S.
- Venue
- Archives of Physical Medicine and Rehabilitation
- Publisher
- Elsevier BV
- Published
- 2002-07
- Volume
- 83
- Issue
- 7
- Pages
- 952-959
- ISSN
- 0003-9993 (ISSN-L)
- OpenAlex
- W2113585314
- Cited by
- 1,159
- References
- 46
- Citations by year
- 2026: 19 · 2025: 20 · 2024: 25 · 2023: 26 · 2022: 48 · 2021: 34 · 2020: 41 · 2019: 57 · 2018: 67 · 2017: 61 · 2016: 81 · 2015: 58 · 2014: 62 · 2013: 68 · 2012: 55
- FWCI
- 28.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Archives of Physical Medicine and Rehabilitation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Neurology › Transcranial Magnetic Stimulation Studies
- Keywords
- stroke rehabilitation, upper limb motor function, hemiparesis, neurodevelopmental treatment, Fugl-Meyer Assessment, FIM, arm muscle strength, reaching kinematics, chronic stroke
- MeSH terms
- Stroke Rehabilitation, Aged, Analysis of Variance, Arm, Biomechanical Phenomena, Chronic Disease, Feedback, Follow-Up Studies, Humans, Muscle Contraction, Paresis, Robotics, Stress, Mechanical, Motion Therapy, Continuous Passive, Range of Motion, Articular, Treatment Outcome, Sample Size, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review