The DOI matches its Crossref record.
Cardiac rotation and relaxation in patients with aortic valve stenosis
Open accessAbstract
BACKGROUND: Diastolic dysfunction with delayed relaxation and abnormal passive elastic properties has been described in patients with severe pressure overload hypertrophy. The purpose of this study was to evaluate the time course of rotational motion of the left ventricle in patients with aortic valve stenosis using myocardial tagging. METHODS: Myocardial tagging is a non-invasive method based on magnetic resonance which makes it possible to label ('tag') specific myocardial regions. From the motion of the tag's cardiac rotation, radial displacement and translational motion can be determined. In 12 controls and 13 patients with severe aortic valve stenosis systolic and diastolic wall motion was assessed in an apical and basal short axis plane. RESULTS: The normal left ventricle performs a systolic wringing motion around the ventricular long axis with clockwise rotation at the base (-4.4+/-1.6 degrees) and counter-clockwise rotation at the apex (+6.8+/-2.5 degrees) when viewed from the apex. During early diastole an untwisting motion can be observed which precedes diastolic filling. In patients with aortic valve stenosis systolic rotation is reduced at the base (-2.4+/-2.0 degrees; P<0.01) but increased at the apex (+12.0+/-6.0 degrees; P<0.05). Diastolic untwisting is delayed and prolonged with a decrease in normalized rotation velocity (-6.9+/-1.1 s(-1)) when compared to controls (-10.7+/-2.2 s(-1); P<0.001). Maximal systolic torsion is 8.0+/-2.1 degrees in controls and 14.1+/-6.4 degrees (P<0.01) in patients with aortic valve stenosis. CONCLUSIONS: Left ventricular pressure overload hypertrophy is associated with a reduction in basal and an increase in apical rotation resulting in increased torsion of the ventricle. Diastolic untwisting is delayed and prolonged. This may explain the occurrence of diastolic dysfunction in patients with severe pressure overload hypertrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Helle-Valle, T., Crosby, J., Edvardsen, T., Lyseggen, E., Amundsen, B. H., Smith, H.-J., Rosen, B. D., Lima, J. A. C., Torp, H., Ihlen, H., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.531558 · Cited by 705
Twist Mechanics of the Left Ventricle
Sengupta, P. P., Tajik, A. J., Chandrasekaran, K., & Khandheria, B. K. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.02.006 · Cited by 604
A Bioinspired Soft Actuated Material
Roche, E. T., Wohlfarth, R., Overvelde, J. T. B., Vasilyev, N. V., Pigula, F. A., Mooney, D. J., Bertoldi, K., & Walsh, C. J. (2014) · Advanced Materials · doi:10.1002/adma.201304018 · Cited by 272
Assessment of left ventricular function in aortic stenosis
Ozkan, A., Kapadia, S., Tuzcu, M., & Marwick, T. H. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.80 · Cited by 57
Left Ventricular Twist Mechanics to Identify Left Ventricular Noncompaction in Childhood
Sabatino, J., Di Salvo, G., Krupickova, S., Fraisse, A., Prota, C., Bucciarelli, V., Josen, M., Paredes, J., Sirico, D., Voges, I., et al. (2019) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.118.007805 · Cited by 46
Metadata
- Authors
- Nagel, E.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-04-01
- Volume
- 21
- Issue
- 7
- Pages
- 582-589
- ISSN
- 0195-668X (ISSN-L)
- OpenAlex
- W2124882320
- Cited by
- 224
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac rotation and relaxation in patients with aortic valve stenosis. https://app.cochat.ai/papers/10.1053/euhj.1999.1736
- The paper
- Nagel, E. (2000). Cardiac rotation and relaxation in patients with aortic valve stenosis. European Heart Journal. https://doi.org/10.1053/euhj.1999.1736
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.