Sensing issues related to the clinical use of implantable loop recorders
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Aims: The newer insertable loop recorder device (Reveal Plus 9526, Medtronic Inc, Minneapolis MN, U.S.A.) is equipped with auto-activation capabilities. In this study we investigated whether the new device encounters sensitivity problems in the form of oversensing or undersensing. We also tested whether body position changes influence the sensed electrogram's amplitude, therefore affecting the device's autosensing ability. Methods and results: We enrolled 32 patients aged 58·1±11·7 years with a loop recorder implanted either in the left parasternal or in the heart's apex area, to investigate undiagnosed syncopal episodes after initial assessment. During the follow-up period (5·7±2·7 months), that began 6 months after the device implantation, we analysed 284 auto-recorded episodes (103 undersensed and 181 correctly sensed). No oversensing episodes were recorded. The recorded QRS amplitude in five different body positions: supine, left and right lateral, sitting and standing was measured. No statistically significant changes were observed in the different postures. Even when patients were divided into subgroups according to implant site or the occurrence of undersensing episodes, no significant inter- or intra-group differences of the sensed electrogram were observed. Conclusion: Undoubtedly this device is the current gold standard for the diagnosis of unexplained syncope. In the population we studied though, the device faced undersensing problems. Consequently, the device should be equipped with more advanced software for QRS morphology recognition, to improve the diagnostic accuracy of the recorder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Krahn, A. D., Klein, G. J., Yee, R., & Norris, C. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00237-9 · Cited by 151
Krahn, A. D., Klein, G. J., Yee, R., & Mandab, V. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70411-4 · Cited by 95
Cited by
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Self-citationUtility of Implantable Loop Recorder (Reveal Plus®) in the Diagnosis of Unexplained Syncope
LOMBARDI, F., CALOSSO, E., MASCIOLI, G., MARANGONI, E., DONATO, A., ROSSI, S., PALA, M., FOTI, F., & LUNATI, M. (2005) · Europace · doi:10.1016/j.eupc.2004.09.003 · Cited by 76
“Even after multiple refinements of programming to achieve adequate sensing, this may still be a clinical problem [19].”
BackgroundDetection of asymptomatic arrhythmias in unexplained syncope
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2004) · American Heart Journal · doi:10.1016/j.ahj.2004.01.024 · Cited by 76
Metadata
- Authors
- Chrysostomakis, S. I., Klapsinos, N. C., Simantirakis, E. N., Marketou, M. E., Kambouraki, D. C., & Vardas, P. E.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-04-01
- Volume
- 5
- Issue
- 2
- Pages
- 143-148
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2140897402
- Cited by
- 47
- References
- 3
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensing issues related to the clinical use of implantable loop recorders. https://app.cochat.ai/papers/10.1053/eupc.2002.0301
- The paper
- Chrysostomakis, S. I., Klapsinos, N. C., Simantirakis, E. N., Marketou, M. E., Kambouraki, D. C., & Vardas, P. E. (2003). Sensing issues related to the clinical use of implantable loop recorders. EP Europace. https://doi.org/10.1053/eupc.2002.0301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.