CoChat

A Computerized Provider Order Entry Intervention for Medication Safety During Acute Kidney Injury: A Quality Improvement Report

Open access
McCoy, Allison B., Waitman, Lemuel R., Gadd, Cynthia S., Danciu, Ioana, Smith, James P., Lewis, Julia B., Schildcrout, Jonathan S., Peterson, Josh F. · 2010 · American Journal of Kidney Diseases
Cited by 124

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background Frequently, prescribers fail to account for changing kidney function when prescribing medications. We evaluated the use of a computerized provider order entry intervention to improve medication management during acute kidney injury (AKI). Study Design Quality improvement report with time series analyses. Setting & Participants 1598 adult inpatients with a minimum 0.5 mg/dl increase in serum creatinine over 48 hours following an order for at least one of 122 nephrotoxic or renally cleared medications. Quality Improvement Plan Passive, non-interactive warnings about increasing serum creatinine appeared within the computerized provider order entry interface and on printed rounding reports. For contraindicated or high toxicity medications that should be avoided or adjusted, an interruptive alert within the system asked providers to modify or discontinue the targeted orders, mark the current dosing as correct and to remain unchanged, or defer the alert to reappear in the next session. Outcomes & Measurements Intervention effect on drug modification or discontinuation, time to modification or discontinuation, provider interactions with alerts. Results The modification or discontinuation rate per 100 events for medications included in the interruptive alert within 24 hours of increasing creatinine improved from 35.2 pre-intervention to 52.6 post-intervention (p<0.001); orders were modified or discontinued more quickly (p<0.001). During the post-intervention period, providers initially deferred 78.1% of interruptive alerts, although 54% of these were eventually modified or discontinued prior to patient death, discharge, or transfer. The response to passive alerts about medications requiring review did not significantly change when compared to baseline. Limitations Single tertiary care academic medical center; provider actions were not independently adjudicated for appropriateness. Conclusions A computerized provider order entry-based alerting system to support medication management following AKI significantly increased the rate and timeliness of modification or discontinuation of targeted medications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.ajkd.2010.05.024

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
McCoy, A. B., Waitman, L. R., Gadd, C. S., Danciu, I., Smith, J. P., Lewis, J. B., Schildcrout, J. S., & Peterson, J. F.
Venue
American Journal of Kidney Diseases
Publisher
Elsevier BV
Published
2010-11
Volume
56
Issue
5
Pages
832-841
ISSN
0272-6386 (ISSN-L)
OpenAlex
W1995528550
Cited by
124
References
9
FWCI
13.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.