Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Dialysate Potassium, Serum Potassium, Mortality, and Arrhythmia Events in Hemodialysis: Results From the Dialysis Outcomes and Practice Patterns Study (DOPPS)

Open access
Karaboyas, Angelo, Zee, Jarcy, Brunelli, Steven M., Usvyat, Len A., Weiner, Daniel E., Maddux, Franklin W., Nissenson, Allen R., Jadoul, Michel, Locatelli, Francesco, Winkelmayer, Wolfgang C., Port, Friedrich K., Robinson, Bruce M., Tentori, Francesca · 2017 · American Journal of Kidney Diseases

Abstract

BACKGROUND: Sudden death is a leading cause of death in patients on maintenance hemodialysis therapy. During hemodialysis sessions, the gradient between serum and dialysate levels results in rapid electrolyte shifts, which may contribute to arrhythmias and sudden death. Controversies exist about the optimal electrolyte concentration in the dialysate; specifically, it is unclear whether patient outcomes differ among those treated with a dialysate potassium concentration of 3 mEq/L compared to 2 mEq/L. STUDY DESIGN: Prospective cohort study. SETTING & PARTICIPANTS: 55,183 patients from 20 countries in the Dialysis Outcomes and Practice Patterns Study (DOPPS) phases 1 to 5 (1996-2015). PREDICTOR: Dialysate potassium concentration at study entry. OUTCOMES: Cox regression was used to estimate the association between dialysate potassium concentration and both all-cause mortality and an arrhythmia composite outcome (arrhythmia-related hospitalization or sudden death), adjusting for potential confounders. RESULTS: During a median follow-up of 16.5 months, 24% of patients died and 7% had an arrhythmia composite outcome. No meaningful difference in clinical outcomes was observed for patients treated with a dialysate potassium concentration of 3 versus 2 mEq/L (adjusted HRs were 0.96 [95% CI, 0.91-1.01] for mortality and 0.98 [95% CI, 0.88-1.08] for arrhythmia composite). Results were similar across predialysis serum potassium levels. As in prior studies, higher serum potassium level was associated with adverse outcomes. However, dialysate potassium concentration had only minimal impact on serum potassium level measured predialysis (+0.09 [95% CI, 0.05-0.14] mEq/L serum potassium per 1 mEq/L greater dialysate potassium concentration). LIMITATIONS: Data were not available for delivered (vs prescribed) dialysate potassium concentration and postdialysis serum potassium level; possible unmeasured confounding. CONCLUSIONS: In combination, these results suggest that approaches other than altering dialysate potassium concentration (eg, education on dietary potassium sources and prescription of potassium-binding medications) may merit further attention to reduce risks associated with high serum potassium levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.ajkd.2016.09.015

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Karaboyas, A., Zee, J., Brunelli, S. M., Usvyat, L. A., Weiner, D. E., Maddux, F. W., Nissenson, A. R., Jadoul, M., Locatelli, F., Winkelmayer, W. C., Port, F. K., Robinson, B. M., & Tentori, F.
Venue
American Journal of Kidney Diseases
Publisher
Elsevier BV
Published
2017-02
Volume
69
Issue
2
Pages
266-277
ISSN
0272-6386 (ISSN-L)
OpenAlex
W2551572216
Cited by
183
References
3
FWCI
11.79
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.