The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Narrow-Band Imaging for Detection of Neoplasia at Colonoscopy: A Meta-analysis of Data From Individual Patients in Randomized Controlled Trials
Abstract
BACKGROUND & AIMS Adenoma detection rate (ADR) is an important quality assurance measure for colonoscopy. Some studies suggest that narrow band imaging (NBI) may be more effective at detection of adenomas than white-light endoscopy (WLE) when bowel preparation is optimal. We conducted a meta-analysis of data from individual patients in randomized controlled trials that compared the efficacy of NBI to WLE in detection of adenomas. METHODS We searched MEDLINE, EMBASE, and Cochrane library databases, through April 2017, for randomized controlled trials that assessed detection of colon polyps by high-definition WLE vs NBI and from which data on individual patients was available. The primary outcome measure was ADR adjusted for bowel preparation quality. Multilevel regression models were used with patients nested within trials, and trial included as a random effect. RESULTS We collected data from 11 trials, comprising 4491 patients and 6636 polyps detected. Adenomas were detected in 952/2251 (42.3%) participants examined by WLE vs 1011/2239 (45.2%) participants examined by NBI (unadjusted odds ratio [OR] for detection of adenoma by WLE vs NBI, 1.14; 95% CI, 1.01-1.29; P=.04). NBI outperformed WLE only when bowel preparation was best: adequate preparation OR, 1.07 (95% CI, 0.92-1.24; P=.38) vs best preparation OR, 1.30 (95% CI, 1.04-1.62; P=.02). Second-generation bright NBI had a better ADR than WLE (second-generation NBI OR, 1.28; 95% CI, 1.05-1.56; P=.02), whereas first-generation NBI did not. NBI detected more non-adenomatous polyps than WLE (OR, 1.24; 95% CI, 1.06-1.44; P=.008) and flat polyps than WLE (OR, 1.24; 95% CI, 1.02-1.51; P=.03). CONCLUSIONS In a meta-analysis of data from individual patients in randomized controlled trials, we found NBI to have a higher ADR than WLE, and that this effect is greater when bowel preparation is optimal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Cited by
Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial
Repici, A., Badalamenti, M., Maselli, R., Correale, L., Radaelli, F., Rondonotti, E., Ferrara, E., Spadaccini, M., Alkandari, A., Fugazza, A., et al. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.04.062 · Cited by 646
Self-citationKamiński, M., Hassan, C., Bisschops, R., Pohl, J., Pellisé, M., Dekker, E., Ignjatovic-Wilson, A., Hoffman, A., Longcroft-Wheaton, G., Heresbach, D., et al. (2014) · Endoscopy · doi:10.1055/s-0034-1365348 · Cited by 433
Self-citationBisschops, R., East, J. E., Hassan, C., Hazewinkel, Y., Kamiński, M. F., Neumann, H., Pellisé, M., Antonelli, G., Bustamante Balen, M., Coron, E., et al. (2019) · Endoscopy · doi:10.1055/a-1031-7657 · Cited by 340
Self-citationOptimizing the quality of colorectal cancer screening worldwide
Kaminski, M. F., Robertson, D. J., Senore, C., & Rex, D. K. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.11.026 · Cited by 171
Self-citationColonoscopy screening and surveillance guidelines
Saito, Y., Oka, S., Kawamura, T., Shimoda, R., Sekiguchi, M., Tamai, N., Hotta, K., Matsuda, T., Misawa, M., Tanaka, S., et al. (2021) · Digestive Endoscopy · doi:10.1111/den.13972 · Cited by 170
Self-citation
Metadata
- Authors
- Atkinson, N. S. S., Ket, S., Bassett, P., Aponte, D., De Aguiar, S., Gupta, N., Horimatsu, T., Ikematsu, H., Inoue, T., Kaltenbach, T., Leung, W. K., Matsuda, T., Paggi, S., Radaelli, F., Rastogi, A., Rex, D. K., Sabbagh, L. C., Saito, Y., Sano, Y., Saracco, G. M., Saunders, B. P., Senore, C., Soetikno, R., Vemulapalli, K. C., Jairath, V., & East, J. E.
- Venue
- Gastroenterology
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 157
- Issue
- 2
- Pages
- 462-471
- ISSN
- 0016-5085 (ISSN-L)
- OpenAlex
- W2937903160
- Cited by
- 172
- References
- 1
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Narrow-Band Imaging for Detection of Neoplasia at Colonoscopy: A Meta-analysis of Data From Individual Patients in Randomized Controlled Trials. https://app.cochat.ai/papers/10.1053/j.gastro.2019.04.014
- The paper
- Atkinson, N. S. S., Ket, S., Bassett, P., Aponte, D., De Aguiar, S., Gupta, N., Horimatsu, T., Ikematsu, H., Inoue, T., Kaltenbach, T., Leung, W. K., Matsuda, T., Paggi, S., Radaelli, F., Rastogi, A., Rex, D. K., Sabbagh, L. C., Saito, Y., Sano, Y., . . . East, J. E. (2019). Narrow-Band Imaging for Detection of Neoplasia at Colonoscopy: A Meta-analysis of Data From Individual Patients in Randomized Controlled Trials. Gastroenterology. https://doi.org/10.1053/j.gastro.2019.04.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.