Automated Artificial Intelligence Model Trained on a Large Data Set Can Detect Pancreas Cancer on Diagnostic Computed Tomography Scans As Well As Visually Occult Preinvasive Cancer on Prediagnostic Computed Tomography Scans
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Background & Aims: The aims of our case-control study were − 1) to develop an automated 3D-Convolutional Neural Network (CNN) for detection of PDA on diagnostic CTs, 2) evaluate its generalizability on multi-institutional public datasets, 3) its utility as a potential screening tool using a simulated cohort with high pretest probability, and 4) its ability to detect visually occult pre-invasive cancer on pre-diagnostic CTs. Methods: A 3D-CNN classification system was trained using algorithmically generated bounding boxes and pancreatic masks on a curated dataset of 696 portal phase diagnostic CTs with PDA and 1080 controls with non-neoplastic pancreas. Model was evaluated on (a) an intramural hold-out test subset (409 CTs with PDA, 829 controls); (b) a simulated cohort with a case-control distribution that matched the risk of PDA in glycemically-defined new-onset diabetes and END-PAC score ≥3; (c) multi-institutional public datasets (194 CTs with PDA, 80 controls), and (d) a cohort of 100 pre-diagnostic CTs (i.e., CTs incidentally acquired 3–36 months before clinical diagnosis of PDA) without a focal mass, and 134 controls. Results: Majority CTs (n=798; 64%) in intramural test subset were from outside hospitals. The model correctly classified 360 (88%) CTs with PDA and 783 (94%) controls [accuracy (mean; 95% CI) 0·92 (0·91–0·94); AUROC 0·97 (0·96–0·98), sensitivity 0·88 (0·85–0·91), specificity 0·95 (0·93–0·96)]. Activation areas on heat maps overlapped with the tumor in most CTs (350/360 CTs; 97%). Performance was high across tumor stages (sensitivity 0·80, 0·87, 0·95 and 1.0 on T1 through T4 stages, respectively), comparable for hypodense versus isodense tumors (sensitivity: 0·90 vs. 0·82), different age, sex, CT slice thicknesses & vendors (all p >0·05), and generalizable on both the simulated cohort [accuracy 0·95 (0·94–0·95), AUROC 0·97 (0·94–0·99)] and public datasets [accuracy 0·86 (0·82–0·90), AUROC 0·90 (0·86–0·95)]. Despite being exclusively trained on diagnostic CTs with larger tumors, the model could detect occult PDA on pre-diagnostic CTs [accuracy 0·84 (0·79–0·88), AUROC 0·91 (0·86–0·94), sensitivity 0·75 (0·67–0·84), specificity 0·90 (0·85–0·95)] at a median 475 days (range: 93–1082) prior to clinical diagnosis. Conclusions: Automated AI model trained on a large and diverse dataset shows high accuracy and generalizable performance for detection of PDA on diagnostic CTs as well as for visually occult PDA on pre-diagnostic CTs. Prospective validation with blood-based biomarkers is warranted to assess the potential for early detection of sporadic PDA in high-risk subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
Empirical Evaluation of Rectified Activations in Convolutional Network
Xu, B., Wang, N., Chen, T., & Li, M. (2015) · arXiv · doi:10.48550/arxiv.1505.00853 · Cited by 2,264
The false hope of current approaches to explainable artificial intelligence in health care
Ghassemi, M., Oakden-Rayner, L., & Beam, A. L. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00208-9 · Cited by 1,724
Preparing Medical Imaging Data for Machine Learning
Willemink, M. J., Koszek, W. A., Hardell, C., Wu, J., Fleischmann, D., Harvey, H., Folio, L. R., Summers, R. M., Rubin, D. L., & Lungren, M. P. (2020) · Radiology · doi:10.1148/radiol.2020192224 · Cited by 1,020
Canto, M. I., Almario, J. A., Schulick, R. D., Yeo, C. J., Klein, A., Blackford, A., Shin, E. J., Sanyal, A., Yenokyan, G., Lennon, A. M., et al. (2018) · Gastroenterology · doi:10.1053/j.gastro.2018.05.035 · Cited by 414
Model to determine risk of pancreatic cancer in patients with new-onset diabetes
Sharma, A., Kandlakunta, H., Nagpal, S. J. S., Feng, Z., Hoos, W., Petersen, G. M., & Chari, S. T. (2018) · Gastroenterology · doi:10.1053/j.gastro.2018.05.023 · Cited by 394
Self-citationEarly Detection of Sporadic Pancreatic Cancer: Summative Review
Chari, S. T., Kelly, K., Hollingsworth, M. A., Thayer, S. P., Ahlquist, D. A., Andersen, D. K., Batra, S. K., Brentnall, T. A., Canto, M., Cleeter, D. F., et al. (2015) · Pancreas · doi:10.1097/mpa.0000000000000368 · Cited by 295
Self-citationLiu, K.-L., Wu, T., Chen, P.-T., Tsai, Y. M., Roth, H., Wu, M.-S., Liao, W.-C., & Wang, W. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30078-9 · Cited by 222
Mukherjee, S., Patra, A., Khasawneh, H., Korfiatis, P., Rajamohan, N., Suman, G., Majumder, S., Panda, A., Johnson, M. P., Larson, N. B., et al. (2022) · Gastroenterology · doi:10.1053/j.gastro.2022.06.066 · Cited by 187
Self-citation
Cited by
Artificial intelligence in surgery
Varghese, C., Harrison, E. M., O’Grady, G., & Topol, E. J. (2024) · Nature Medicine · doi:10.1038/s41591-024-02970-3 · Cited by 287
Artificial Intelligence in Pancreatic Imaging: A Systematic Review
Podină, N., Gheorghe, E. C., Constantin, A., Cazacu, I., Croitoru, V., Gheorghe, C., Balaban, D. V., Jinga, M., Țieranu, C. G., & Săftoiu, A. (2025) · United European Gastroenterology Journal · doi:10.1002/ueg2.12723 · Cited by 48
Pancreatic Adenocarcinoma: Imaging Modalities and the Role of Artificial Intelligence
Anghel, C., Mugur, G. C., Anghel, D. A., Rusu-Munteanu, G. I., Dumitru, R. L., & Lupescu, I. G. (2024) · doi:10.20944/preprints202401.0904.v1 · Cited by 23
A scoping review of silent trials for medical artificial intelligence
Tikhomirov, L., Semmler, C., Prizant, N., Bhasin, S., Kenyon, G., van der Vegt, A., Erdman, L., Kurian, N. C., Thompson, H., Palmer, L. J., et al. (2026) · Nature Health · doi:10.1038/s44360-025-00048-z · Cited by 17
Metadata
- Authors
- Korfiatis, P., Suman, G., Patnam, N. G., Trivedi, K. H., Karbhari, A., Mukherjee, S., Cook, C., Klug, J. R., Patra, A., Khasawneh, H., Rajamohan, N., Fletcher, J. G., Truty, M. J., Majumder, S., Bolan, C. W., Sandrasegaran, K., Chari, S. T., & Goenka, A. H.
- Venue
- Gastroenterology
- Publisher
- Elsevier BV
- Published
- 2023-12
- Volume
- 165
- Issue
- 6
- Pages
- 1533-1546.e4
- ISSN
- 0016-5085 (ISSN-L)
- OpenAlex
- W4386295956
- Cited by
- 73
- References
- 19
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Artificial Intelligence Model Trained on a Large Data Set Can Detect Pancreas Cancer on Diagnostic Computed Tomography Scans As Well As Visually Occult Preinvasive Cancer on Prediagnostic Computed Tomography Scans. https://app.cochat.ai/papers/10.1053/j.gastro.2023.08.034
- The paper
- Korfiatis, P., Suman, G., Patnam, N. G., Trivedi, K. H., Karbhari, A., Mukherjee, S., Cook, C., Klug, J. R., Patra, A., Khasawneh, H., Rajamohan, N., Fletcher, J. G., Truty, M. J., Majumder, S., Bolan, C. W., Sandrasegaran, K., Chari, S. T., & Goenka, A. H. (2023). Automated Artificial Intelligence Model Trained on a Large Data Set Can Detect Pancreas Cancer on Diagnostic Computed Tomography Scans As Well As Visually Occult Preinvasive Cancer on Prediagnostic Computed Tomography Scans. Gastroenterology. https://doi.org/10.1053/j.gastro.2023.08.034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.