The DOI matches its Crossref record.
The effect of axial tibial torque on the function of the anterior cruciate ligament
Abstract
PURPOSE: Various techniques are used to produce the pivot shift phenomenon after anterior cruciate ligament (ACL) injury. In particular, the amount of applied axial tibial torque varies among examiners. Thus, the objective of this study was to determine the effect of the magnitude and direction of axial tibial torque in combination with valgus torque on the resulting knee kinematics during such a simulated pivot shift test. TYPE OF STUDY: This was a biomechanical study that used cadaveric knees with the intact knee of the same specimen serving as a control. METHODS: On 19 human cadaveric knees (age, 26 to 69 years), a constant 10-Nm valgus torque was applied at 15 degrees of knee flexion. Then, internal and external tibial torque was applied incrementally from 0 to 10 Nm and the resulting kinematics of the ACL-intact and ACL-deficient knee, as well as the in situ force in the ACL, were measured using a robotic/universal force-moment sensor testing system. RESULTS: In response to isolated valgus torque, the coupled anterior tibial translation for the ACL-intact and ACL-deficient knee was 1.6 +/- 2.4 mm and 8.5 +/- 4.7 mm, respectively; therefore the difference between the ACL-intact and ACL-deficient knee was 6.9 +/- 3.4 mm. With an external tibial torque greater than 5 Nm, the tibia translated up to 4 mm posteriorly for both the ACL-intact and ACL-deficient knee. Whereas, internal tibial torque greater than 1.6 Nm caused a rapid increase in coupled anterior tibial translation up to 10.2 mm in the ACL-deficient knee, while causing only a gradual increase for the ACL-intact knee. With excessive internal torque of 10 Nm, the difference in coupled anterior tibial translation was only 4.4 +/- 2.2 mm, suggesting a decrease in the sensitivity of the test. Correspondingly, the in situ force in the ACL under 10 Nm valgus tibial torque was 43 +/- 17 N, and increased up to 87 +/- 32 N as a 10-Nm internal torque was added. By applying a 3.3-Nm external tibial torque in addition to the 10-Nm valgus torque, the in situ force decreased to 21 +/- 14 N. CONCLUSIONS: This study showed that a minimal amount of internal torque in combination with valgus torque may be a suitable way to elicit a pivot shift from an ACL-deficient knee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Musahl, V., Plakseychuk, A., Vanscyoc, A., Sasaki, T., Debski, R. E., Mcmahon, P. J., & Fu, F. H. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504271747 · Cited by 331
Self-citationMurray, P. J., Alexander, J. W., Gold, J. E., Icenogle, K. D., Noble, P. C., & Lowe, W. R. (2010) · Arthroscopy · doi:10.1016/j.arthro.2009.07.014 · Cited by 48
Metadata
- Authors
- Kanamori, A., Zeminski, J., Rudy, T. W., Li, G., Fu, F. H., & Woo, S. L.-Y.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2002-04
- Volume
- 18
- Issue
- 4
- Pages
- 394-398
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2129315824
- Cited by
- 231
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effect of axial tibial torque on the function of the anterior cruciate ligament. https://app.cochat.ai/papers/10.1053/jars.2002.30638
- The paper
- Kanamori, A., Zeminski, J., Rudy, T. W., Li, G., Fu, F. H., & Woo, S. L.-Y. (2002). The effect of axial tibial torque on the function of the anterior cruciate ligament. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1053/jars.2002.30638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.