The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Varying Femoral Tunnels between the Anatomical Footprint and Isometric Positions: Effect on Kinematics of the Anterior Cruciate Ligament-Reconstructed Knee
Abstract
Background: Knee kinematics and in situ forces resulting from anterior cruciate ligament reconstructions with 2 femoral tunnel positions were evaluated. Hypothesis: A graft placed inside the anatomical footprint of the anterior cruciate ligament will restore knee function better than a graft placed at a position for best graft isometry. Study Design: Controlled laboratory study. Methods: Ten cadaveric knees were tested in response to a 134-N anterior load and a combined 10-N·m valgus and 5-N·m internal rotation load. A robotic universal force-moment sensor testing system was used to apply loads, and resulting kinematics were recorded. An active surgical robot system was used for positioning tunnels in 2 locations in the femoral notch: inside the anatomical footprint of the anterior cruciate ligament and a position for best graft isometry. The same quadrupled hamstring tendon graft was used for both tunnel positions. The 2 loading conditions were applied. Results: At 30° of knee flexion, anterior tibial translation in response to the anterior load for the intact knee was 9.8 ± 3.1 mm. Both femoral tunnel positions resulted in significantly higher anterior tibial translation (position 1: 13.8 ± 4.6 mm; position 2: 16.6 ± 3.7 mm; P <. 05). There was a significant difference between the 2 tunnel positions. At the same flexion angle, the anterior tibial translation in response to the combined load for the intact knee was 7.7 ± 4.0 mm. Both femoral tunnel positions resulted in significantly higher anterior tibial translation (position 1: 10.4 ± 5.5 mm; position 2: 12.0 ± 5.2 mm; P <. 05), with a significant difference between the tunnel positions. Conclusion: Neither femoral tunnel position restores normal kinematics of the intact knee. A femoral tunnel position inside the anatomical footprint of the anterior cruciate ligament results in knee kinematics closer to the intact knee than does a tunnel position located for best graft isometry. Clinical Relevance: Anatomical femoral tunnel position is important in reproducing function of the anterior cruciate ligament.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical Analysis of an Anatomic Anterior Cruciate Ligament Reconstruction
Yagi, M., Wong, E. K., Kanamori, A., Debski, R. E., Fu, F. H., & Woo, S. L.-Y. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300050501 · Cited by 988
Self-citationFemoral insertion of the ACL. Radiographic quadrant method.
Bernard, M., Hertel, P., Hornung, H., & Cierpinski, T. (1997) · PubMed · Cited by 634
Markolf, K. L., Gorek, J. F., Kabo, J. M., & Shapiro, M. S. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00014 · Cited by 610 · cited 1×
“Various devices and methods have been applied to measure the force and strain in the ACL and ACL replacement grafts.(1,5,20) With the use of these devices, valuable information on forces and strains experienced by the ligaments has been obtained.”
MethodHefzy, M. S., Grood, E. S., & Noyes, F. R. (1989) · The American Journal of Sports Medicine · doi:10.1177/036354658901700210 · Cited by 450
Importance of the medial meniscus in the anterior cruciate ligament‐deficient knee
Allen, C. R., Wong, E. K., Livesay, G. A., Sakane, M., Fu, F. H., & Woo, S. L. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180116 · Cited by 427
Self-citationAnterior cruciate ligament graft positioning, tensioning and twisting
Amis, A. A., & Jakob, R. P. (1998) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050215 · Cited by 387
Ligament length relationships in the moving knee
Sidles, J. A., Larson, R. V., Garbini, J. L., Downey, D. J., & Matsen, F. A. (1988) · Journal of Orthopaedic Research · doi:10.1002/jor.1100060418 · Cited by 370
A combined robotic/universal force sensor approach to determine in situ forces of knee ligaments
Rudy, T. W., Livesay, G. A., Woo, S. L., & Fu, F. H. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00056-5 · Cited by 279
Self-citationThe effect of axial tibial torque on the function of the anterior cruciate ligament
Kanamori, A., Zeminski, J., Rudy, T. W., Li, G., Fu, F. H., & Woo, S. L.-Y. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30638 · Cited by 231
Self-citationLivesay, G. A., Fujie, H., Kashiwaguchi, S., Morrow, D. A., Fu, F. H., & Woo, S. L. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584446 · Cited by 155
Self-citation
Cited by
Zantop, T., Wellmann, M., Fu, F. H., & Petersen, W. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546507308361 · Cited by 344
Self-citation
Metadata
- Authors
- Musahl, V., Plakseychuk, A., Vanscyoc, A., Sasaki, T., Debski, R. E., Mcmahon, P. J., & Fu, F. H.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2005-05
- Volume
- 33
- Issue
- 5
- Pages
- 712-718
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2134630947
- Cited by
- 331
- References
- 23
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Varying Femoral Tunnels between the Anatomical Footprint and Isometric Positions: Effect on Kinematics of the Anterior Cruciate Ligament-Reconstructed Knee. https://app.cochat.ai/papers/10.1177/0363546504271747
- The paper
- Musahl, V., Plakseychuk, A., Vanscyoc, A., Sasaki, T., Debski, R. E., Mcmahon, P. J., & Fu, F. H. (2005). Varying Femoral Tunnels between the Anatomical Footprint and Isometric Positions: Effect on Kinematics of the Anterior Cruciate Ligament-Reconstructed Knee. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546504271747
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.