Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 397

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Critical flicker frequency for quantification of low-grade hepatic encephalopathy

Kircheis, Gerald, Wettstein, Matthias, Timmermann, Lars, Schnitzler, Alfons, Häussinger, Dieter·2002·Hepatology

Abstract

Subclinical hepatic encephalopathy (SHE) is currently diagnosed by psychometric tests or neurophysiologic techniques. In view of its sociomedical relevance, simple and reproducible tests for routine diagnosis are required. This study evaluates critical flicker-frequency thresholds for quantification of low-grade hepatic encephalopathy. A total of 115 patients (92 with cirrhosis, 23 controls) were analyzed for HE severity (mental state, computerized psychometric tests), and the threshold frequencies at which light pulses are perceived as fused (fusion frequency) or flickering light (critical flicker frequency [CFF]). CFF was a highly reproducible parameter with little age, day-time, and training dependency. CFFs in cirrhotic patients without HE (HE 0) were not different from those found in noncirrhotic controls. Significantly lower CFFs were found in cirrhotic patients with subclinical or manifest HE, and the various HE groups separated from each other at a high level of significance (P < .01). By using a CFF cut-off value of 39 Hz, a 100% separation of patients with manifest HE from noncirrhotic controls and HE 0 cirrhotic patients was obtained. SHE patients separated from HE 0 cirrhotic patients with high sensitivity (55%) and specificity (100%). The HE severity-dependent differences were found in both, alcoholic and posthepatitic cirrhosis. Statistically significant correlations (P < .01) were found between CFFs and individual psychometric tests. Aggravation of preexisting HE after transjugular intrahepatic portosystemic stent shunt (TIPS) implantation was accompanied by a corresponding decrease of CFF, whereas improvement of HE increased CFF. In conclusion, CFF is a sensitive, simple, and reliable parameter for quantification of low-grade HE severity in cirrhotic patients and may be useful for the detection and monitoring of SHE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/jhep.2002.30957

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Metadata

Authors
Kircheis, G., Wettstein, M., Timmermann, L., Schnitzler, A., & Häussinger, D.
Venue
Hepatology
Published
2002-02
Volume
35
Issue
2
Pages
357-366
ISSN
0270-9139 (ISSN-L)
OpenAlex
W2039560063
Cited by
397
References
22
FWCI
5.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Critical flicker frequency for quantification of low-grade hepatic encephalopathy. https://app.cochat.ai/papers/10.1053/jhep.2002.30957
The paper
Kircheis, G., Wettstein, M., Timmermann, L., Schnitzler, A., & Häussinger, D. (2002). Critical flicker frequency for quantification of low-grade hepatic encephalopathy. Hepatology. https://doi.org/10.1053/jhep.2002.30957

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.