Glucagon Radioimmunoassay Using Antiserum 30K: Interference by Plasma
The DOI matches its Crossref record.
Abstract
Studies of a glucagon radioimmunoassay using antiserum 30K suggest that when plasma samples from different individuals are assayed against a single standard curve, an inappropriately wide range of values for fasting human pancreatic glucagon levels is obtained. Evidence is presented that plasma from different subjects contains non-specific factors which interfere with the assay. These factors depress the binding of labeled glucagon but appear to be neither pancreatic glucagon nor an enteric factor with glucagon-like immunoreactivity. A correction can be made for these interference factors in a given patient because the factors can be quantitated following adsorption of glucagon with charcoal. Fasting immunoreactive glucagon (IRG) levels were determined on the plasma from 13 normal subjects. When all samples were measured against a standard curve using no correction factor the range was 45-295 pg/ml (mean ± standard deviation 131 ± 73.8). Using a correction factor the measured fasting glucagon values were 25-60 pg/ml (mean ± S.D. 43 ± 12.3). Fasting glucagon levels as conventionally determined using antiserum 30K are probably inaccurate, and the use of a correction factor is advisable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Somatostatin: Hypothalamic Inhibitor of the Endocrine Pancreas
Koerker, D. J., Ruch, W., Chideckel, E., Palmer, J., Goodner, C. J., Ensinck, J., & Gale, C. C. (1974) · Science · doi:10.1126/science.184.4135.482 · Cited by 519
Dunning, B. E., & Gerich, J. E. (2007) · Endocrine Reviews · doi:10.1210/er.2006-0026 · Cited by 369
“Somatostatinoma”: A Somatostatin-Containing Tumor of the Endocrine Pancreas
Ganda, O. P., Weir, G. C., Soeldner, J. S., Legg, M. A., Chick, W. L., Patel, Y. C., Ebeid, A. M., Gabbay, K. H., & Reichlin, S. (1977) · New England Journal of Medicine · doi:10.1056/nejm197704282961703 · Cited by 290
Self-citationMeasuring Oxytocin and Vasopressin: Bioassays, Immunoassays and Random Numbers
Leng, G., & Sabatier, N. (2016) · Journal of Neuroendocrinology · doi:10.1111/jne.12413 · Cited by 237
“Such interference has also been recognised in immunoassays for chole-cystokinin (80), parathyroid hormone (81), thyrotropic hormone (82), glucagon (83), secretin (84,85), angiotensin (86), growth hormone (87), vasoactive intestinal peptide (88), gonadotrophins (89) and gonadotrophin-releasing…”
BackgroundValverde, I., Dobbs, R., & Unger, R. H. (1975) · Metabolism · doi:10.1016/0026-0495(75)90095-5 · Cited by 92
Metadata
- Authors
- Weir, G., Turner, R., & Martin, D.
- Venue
- Hormone and Metabolic Research
- Publisher
- Georg Thieme Verlag KG
- Published
- 1973
- Volume
- 5
- Issue
- 04
- Pages
- 241-244
- ISSN
- 0018-5043 (ISSN-L)
- 1439-4286
- OpenAlex
- W2048823071
- Cited by
- 86
- References
- 0
- FWCI
- 9.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glucagon Radioimmunoassay Using Antiserum 30K: Interference by Plasma. https://app.cochat.ai/papers/10.1055/s-0028-1093958
- The paper
- Weir, G., Turner, R., & Martin, D. (1973). Glucagon Radioimmunoassay Using Antiserum 30K: Interference by Plasma. Hormone and Metabolic Research. https://doi.org/10.1055/s-0028-1093958
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.