Influence of Cardiopulmonary Exercise Testing Protocol and Resting VO2Assessment on %HRmax, %HRR, %VO2maxand %VO2R Relationships
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The findings of previous studies investigating the strength of the relationships between the percentages of maximal heart rate (%HR(max)), heart rate reserve (%HRR), maximal oxygen uptake (%VO(2max)), and oxygen uptake reserve (%VO(2)R) have been equivocal. This inconsistency between studies could largely be due to differences in methodology. The purpose of this study was therefore to determine whether different VO(2max) test protocols and resting VO(2) assessment influence the relationships between the %HR(max), %HRR, %VO(2max), and %VO(2)R. Thirty-three young men performed maximal treadmill protocols (ramp, Bruce) to assess HR(max) and VO(2max). Resting VO(2) was assessed as follows: a) resting VO(2standard), using strict criteria (24 h exercise abstention, alcohol, soft drinks, or caffeine; 8 h fasting; 30 min assessment); b) resting VO(2sitting) and; c) resting VO(2standing) (both 5 min before exercise testing). The %HRR was closer to %VO(2max) than to %VO(2)R, especially in the ramp protocol (p<0.001). In the Bruce protocol, relationships were closer to the identity line, and there was no significant difference between %HRR and %VO(2max), or %VO(2)R. The VO(2max) was significantly higher in the ramp protocol compared to the Bruce protocol (p<0.001). In both protocols resting VO(2) assessment produced no significant difference in the intercepts and slopes of the %HRR-%VO(2)R relationships obtained from individual regression models. The %VO(2)R calculated using resting VO(2standard) was closer to %HRR compared to VO(2sitting) and VO(2standing). The premise that %HRR is more strongly related to %VO(2)R than to %VO(2max) was not confirmed. Methodological differences should be considered when interpreting previous studies investigating %HR(max), %HRR, %VO(2max), and %VO(2)R relationships.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656
Compher, C., Frankenfield, D., Keim, N., & Roth-Yousey, L. (2006) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.02.009 · Cited by 923
Wenger, H. A., & Bell, G. J. (1986) · Sports Medicine · doi:10.2165/00007256-198603050-00004 · Cited by 529
Metabolic equivalent: one size does not fit all
Byrne, N. M., Hills, A. P., Hunter, G. R., Weinsier, R. L., & Schutz, Y. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00023.2004 · Cited by 527
Physical activity and resting metabolic rate
Speakman, J. R., & Selman, C. (2003) · Proceedings of The Nutrition Society · doi:10.1079/pns2003282 · Cited by 441
Heart rate reserve is equivalent to %VO2Reserve, not to %VO2max
SWAIN, D. P., & LEUTHOLTZ, B. C. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00018 · Cited by 287
&OV0312;O2 reserve and the minimal intensity for improving cardiorespiratory fitness
SWAIN, D. P., & FRANKLIN, B. A. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200201000-00023 · Cited by 269
A review: exercise and its influence on resting energy metabolism in man
POEHLMAN, E. T. (1989) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198910000-00005 · Cited by 184
Colberg, S. R., Swain, D. P., & Vinik, A. I. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.986 · Cited by 109
Cited by
Garber, C. E., Blissmer, B., Deschenes, M. R., Franklin, B. A., Lamonte, M. J., Lee, I.-M., Nieman, D. C., & Swain, D. P. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318213fefb · Cited by 9,319
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Methods of Prescribing Relative Exercise Intensity: Physiological and Practical Considerations
Mann, T., Lamberts, R. P., & Lambert, M. I. (2013) · Sports Medicine · doi:10.1007/s40279-013-0045-x · Cited by 333
“Recent studies reporting VO2R have adopted these best-practice criteria for determining resting VO2, but did not verify VO2max at supramaximal intensities [22, 24].”
MethodPilon, R., Matos-Santos, L., Matlez, M. P., Rodrigues, G., Amorim, F., Lattari, E., Farinatti, P., & Monteiro, W. (2024) · Journal of Strength & Conditioning Research · doi:10.1519/jsc.0000000000004683 · Cited by 1
Self-citation
Metadata
- Authors
- Cunha, F., Midgley, A., Monteiro, W., & Farinatti, P.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2010-03-03
- Volume
- 31
- Issue
- 05
- Pages
- 319-326
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2095412787
- Cited by
- 77
- References
- 9
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.