Reproducibility of Muscle Oxygen Saturation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The present study evaluated the reproducibility of tissue oxygenation in relation to oxygen consumption (VO2) across cycle exercise intensities in a test-retest design. 12 subjects (25.7±2.1 years; 24.7±1.9 kg · m(-2)) twice performed an incremental bicycle exercise protocol, while tissue oxygen saturation (StO2) in the vastus lateralis muscle was monitored by a commercially available NIRS unit and VO2 determined by an open-circuit indirect calorimetric system. Coefficients of variation across rest, workloads corresponding to 25, 50 and 75% of individual maximum capacity, and maximum load were 5.8, 4.6, 6.1, 8.0, 11.0% (StO2) and 7.6, 6.0, 3.7, 3.4, 3.1% (VO2), respectively. 95 % CI of relative test-retest differences ranged from -5.6 to +5.4% at 25% load to -17.2 to +7.5% at maximum load for StO2 and from -7.3 to +7.7% at rest to -3.3 to +3.2% at maximum load for VO2. With advancing exercise intensity, within-subject variability of StO2 was augmented, whereas VO2 variability slightly attenuated. NIRS measurements at higher workloads need to be interpreted with caution.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“at higher intensity there is a greater standard deviation of SmO2”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Thiel et al., 2011
In the citing paper
“Although reproducibility of ventilatory thresholds [4] and lactate threshold [5] are known to be high, data on reproducibility of NIRS signals [5,20–22] and NIRS derived breakpoints [23] is limited.”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [20]
Citations
Cites
The publisher hasn’t deposited this paper’s reference list.
Cited by
Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1330899 · Cited by 206
“Thiel et al. (2011) attributed the lower reliability of NIRS measurements during cycling exercise at 75% VO2max compared to 25% VO2max to the impairment of muscle perfusion by stronger contractions producing more variable tissue oxygenation.”
BackgroundMcManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Estimated contribution of hemoglobin and myoglobin to near infrared spectroscopy
Davis, M. L., & Barstow, T. J. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.01.012 · Cited by 169
van der Zwaard, S., Jaspers, R. T., Blokland, I. J., Achterberg, C., Visser, J. M., den Uil, A. R., Hofmijster, M. J., Levels, K., Noordhof, D. A., de Haan, A., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162914 · Cited by 95
Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise
Contreras-Briceño, F., Espinosa-Ramirez, M., Hevia, G., Llambias, D., Carrasco, M., Cerda, F., López-Fuenzalida, A., García, P., Gabrielli, L., & Viscor, G. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1653422 · Cited by 40
Metadata
- Authors
- Thiel, C., Vogt, L., Himmelreich, H., Hübscher, M., & Banzer, W.
- Affiliations
- Goethe University Frankfurt (DE)
- University Hospital Frankfurt (DE)
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2011-01-26
- Volume
- 32
- Issue
- 04
- Pages
- 277-280
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2081800721
- Cited by
- 27
- References
- 0
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 2 · 2019: 2 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- muscle oxygen saturation, tissue oxygenation, oxygen consumption, reproducibility, test-retest reliability, vastus lateralis, near-infrared spectroscopy, incremental exercise, within-person variability, exercise intensity
- MeSH terms
- Adult, Bicycling, Calorimetry, Indirect, Exercise Test, Female, Humans, Male, Oxygen, Oxygen Consumption, Reproducibility of Results, Muscle, Skeletal, Spectroscopy, Near-Infrared, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of Muscle Oxygen Saturation. https://app.cochat.ai/papers/10.1055/s-0030-1269922
- The paper
- Thiel, C., Vogt, L., Himmelreich, H., Hübscher, M., & Banzer, W. (2011). Reproducibility of Muscle Oxygen Saturation. International Journal of Sports Medicine. https://doi.org/10.1055/s-0030-1269922
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.