Cited by 40Cardiovascular and exercise physiologySports Performance and TrainingOptical Imaging and Spectroscopy Techniques

Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise

Contreras-Briceño, Felipe, Espinosa-Ramirez, Maximiliano, Hevia, Gonzalo, Llambias, Diego, Carrasco, Miguel, Cerda, Francisco, López-Fuenzalida, Antonio, García, Patricio +2 more·2019·Journal of Sports Sciences

Abstract

This study assessed the intra-individual reliability of oxygen saturation in intercostal muscles (SmO 2 - m.intercostales ) during an incremental maximal treadmill exercise by using portable NIRS devices in a test-retest study. Fifteen marathon runners (age, 24.9 ± 2.0 years; body mass index, 21.6 ± 2.3 kg·m -2 ; V̇O 2 -peak, 63.7 ± 5.9 mL·kg -1 ·min -1 ) were tested on two separate days, with a 7-day interval between the two measurements. Oxygen consumption (V̇O 2 ) was assessed using the breath-by-breath method during the V̇O 2 -test, while SmO 2 was determined using a portable commercial device, based in the near-infrared spectroscopy (NIRS) principle. The minute ventilation (VE), respiratory rate (RR), and tidal volume (Vt) were also monitored during the cardiopulmonary exercise test. For the SmO 2 - m.intercostales , the intraclass correlation coefficient (ICC) at rest, first (VT1) and second ventilatory (VT2) thresholds, and maximal stages were 0.90, 0.84, 0.92, and 0.93, respectively; the confidence intervals ranged from -10.8% - +9.5% to -15.3% - +12.5%. The reliability was good at low intensity (rest and VT1) and excellent at high intensity (VT2 and max). The Spearman correlation test revealed ( p ≤ 0.001) an inverse association of SmO 2 - m.intercostales with V̇O 2 ( ρ = -0.64), VE ( ρ = -0.73), RR ( ρ = -0.70), and Vt ( ρ = -0.63). The relationship with the ventilatory variables showed that increased breathing effort during exercise could be registered adequately u…

Integrity signals

Registry

Crossref · 10.1080/02640414.2019.1653422

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • To obtain sufficient power (β = 0.8, α = 0.05), an a priori sample size calculation was made using previously reported data.

    “To obtain sufficient power of β = 0.8 with α = 0.05, an a priori sample size calculation was made in G*Power software (version 3.1.9.7, Kiel, Germany) using previously reported data from other groups that compared SmO2 values within and between sessions during ramp incremental tests and severe intensity efforts (5, 15, 16, 40, 41).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Contreras-Briceño, F., Espinosa-Ramirez, M., Hevia, G., Llambias, D., Carrasco, M., Cerda, F., López-Fuenzalida, A., García, P., Gabrielli, L., & Viscor, G.
Affiliations
  • Laboratory of Exercise Physiology, Department of Health Science, Faculty of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile
  • Pontificia Universidad Católica de Chile (CL)
  • Universitat de Barcelona (ES)
Venue
Journal of Sports Sciences
Published
2019-08-16
Volume
37
Issue
23
Pages
2653-2659
ISSN
  • 0264-0414 (ISSN-L)
  • 1466-447X
OpenAlex
W2968620153
Cited by
40
References
5
Citations by year
2026: 6 · 2025: 6 · 2024: 7 · 2023: 8 · 2022: 5 · 2021: 5 · 2020: 3
FWCI
4.18
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Sports Sciences (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Universidad de Chile
  • Pontificia Universidad Católica de Chile
Topics
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
near-infrared spectroscopy, muscle oxygen saturation, test-retest reliability, incremental treadmill exercise, ventilatory threshold, oxygen consumption, marathon runners, respiratory effort, respiratory variables
MeSH terms
Adult, Exercise Test, Humans, Intercostal Muscles, Male, Oxygen Consumption, Running, Tidal Volume, Work of Breathing, Reproducibility of Results, Exercise, Spectroscopy, Near-Infrared, Athletic Performance, Young Adult, Respiratory Rate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review