The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test

Open access
Osmani, Florent, Lago-Fuentes, Carlos, Alemany-Iturriaga, Josep, Barcala-Furelos, Martín · 2023 · Frontiers in Physiology

The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index; 6 of the 33 sources its claims cite were checked for support.

Abstract

Introduction: The study aims to explore whether NIRS derived data can be used to identify the second ventilatory threshold (VT2) during a maximal incremental treadmill test in non-professional runners and to determine if there is a correlation between SmO 2 and other valid and reliable exercise performance assessment measures or parameters for maximal incremental test, such as lactate concentration (LT), RPE, HR, and running power (W). Methods: 24 participants were recruited for the study (5 women and 19 men). The devices used consisted of the following: i) a muscle oxygen saturation analyzer placed on the vastus lateralis of the right leg, ii) the Stryd power meter for running, iii) the Polar H7 heart rate band; and iv) the lactate analyzer. In addition, a subjective perceived exertion scale (RPE 1-10) was used. All of the previously mentioned devices were used in a maximal incremental treadmill test, which began at a speed of 8 km/h with a 1% slope and a speed increase of 1.2 km/h every 3 min. This was followed by a 30-s break to collect the lactate data between each 3-min stage. Spearman correlation was carried out and the level of significance was set at p < 0.05. Results: The VT2 was observed at 87,41 ± 6,47% of the maximal aerobic speed (MAS) of each participant. No relationship between lactate data and SmO 2 values (p = 0.076; r = −0.156) at the VT2 were found. No significant correlations were found between the SmO 2 variables and the other variables (p > 0.05), but a high level of significance and strong correlations were found between all the following variables: power data (W), heart rate (HR), lactate concentration (LT) and RPE (p < 0.05; r > 0.5). Discussion: SmO 2 data alone were not enough to determine the VT2, and there were no significant correlations between SmO 2 and the other studied variables during the maximal incremental treadmill test. Only 8 subjects had a breakpoint at the VT2 determined by lactate data. Conclusion: The NIRS tool, Humon Hex, does not seem to be useful in determining VT2 and it does not correlate with the other variables in a maximal incremental treadmill test.

Overview

CoChat Summary

TL;DR

In 21 non-professional runners, the Humon Hex NIRS-derived muscle oxygen saturation (SmO2) did not identify the second ventilatory threshold (VT2) during a maximal incremental treadmill test and showed no significant correlations with lactate, heart rate, running power, or RPE. In contrast, lactate, heart rate, running power, and RPE were strongly intercorrelated.

Key findings

  • VT2 occurred at 87.41 ± 6.47% of maximal aerobic speed (MAS), corresponding to 12.62 ± 1.87 km/h, RPE 6.58 ± 1.77, heart rate 177.74 ± 12.63 bpm, power 252.79 ± 32.94 W, and SmO2 60.47 ± 8.25.
  • SmO2 did not correlate with lactate at VT2 (p = 0.076; r = −0.156) or with HR (r = −0.028; p = 0.752), running power (r = 0.047; p = 0.593), RPE (r = 0.035; p = 0.692), or lactate overall (r = −0.118; p = 0.177).
  • Only 8 of 21 participants had an SmO2 breakpoint at the VT2 determined by lactate data; 10 had no inflection point and 3 did not reach 4 mmol/L to determine VT2.
  • Running power, HR, lactate, and RPE were significantly correlated (p < 0.05; r > 0.5), including W–RPE r = 0.808, HR–RPE r = 0.776, LT–RPE r = 0.769, HR–LT r = 0.717, W–LT r = 0.716, and HR–W r = 0.598; recovery SmO2 vs HR correlations were null (last step to first minute: r = 0.001, p = 0.997; first minute to 3 minutes: r = 0.092, p = 0.690).

Methods

  • Cross-sectional study; 24 participants recruited, 3 excluded for erroneous SmO2 measurements, leaving 21 (5 women, 16 men; age 23.19 ± 4.18 years, weight 68.93 ± 10.99 kg, height 1.75 ± 0.12 m). Inclusion required moderate exercise ≥3 days/week for 30 min over the last 6 months and no injury/disease; athletics license was exclusionary.
  • Maximal incremental treadmill test began at 8 km/h with 1% slope, increased 1.2 km/h every 3 min, with a 30-s stop between stages for lactate collection; test ended after 10 stages or volitional fatigue, followed by 3 min recovery at 6 km/h. Devices: Humon Hex on right vastus lateralis, Stryd power meter on right shoe laces, Polar H7 heart rate band, Lactate Pro 2 from right earlobe, and RPE 1–10.
  • Normality assessed with Shapiro-Wilk (p > 0.05); Spearman correlations used, significance set at p < 0.05; analyses performed in JASP 0.14.1.0; descriptive data as mean ± SD.

Limitations

  • Stated in the paper: small sample size (n = 21), only 5 women, and subcutaneous tissue could not be measured.
  • Stated/discussed in the paper: the 30-s break between stages may have allowed muscle recovery and affected threshold determination; 3 participants were excluded due to erroneous SmO2 measurements from device movement or a device limitation; NIRS measures only a local muscle, and running-related factors such as oscillation, muscle contractions, impact, and sweat may affect accuracy.
  • Evident from the text: VT2 was determined using lactate thresholds rather than direct ventilatory gas exchange, and no gas analyzer data are reported; the cross-sectional design cannot establish causality.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3389/fphys.2023.1155037

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

FIGURE 1 Relationship between lactate concentration and muscle oxygen saturation at each MAS relative intensity of each participant. SmO2—The percentage of muscle oxygen saturation. LT—Lactate concentration in mmol/L. MAS: Maximal aerobic speed.
FIGURE 1 Relationship between lactate concentration and muscle oxygen saturation at each MAS relative intensity of each participant. SmO2—The percentage of muscle oxygen saturation. LT—Lactate concentration in mmol/L. MAS: Maximal aerobic speed.CC BY · PubMed Central
FIGURE 2 Correlation between the variables of SmO2 and HR from the last completed step to the first minute of recovery and from the first minute of recovery to the 3 min of recovery.
FIGURE 2 Correlation between the variables of SmO2 and HR from the last completed step to the first minute of recovery and from the first minute of recovery to the 3 min of recovery.CC BY · PubMed Central
FIGURE 3 Correlation between the variables of SmO2 and HR from the first minute of recovery to the 3 min of recovery. SmO2—The percentage of muscle oxygen saturation. HR—Heart Rate. DSMO2_LAST_1—The difference between the percentage of muscle oxygen saturation since the last completed step to the first recovery minute. DHR_LAST-1—The difference between the heart rate since the last completed step to the first recovery minute. DSMO2_LAST_3—The difference between the percentage of muscle oxygen saturation since the last completed step to the third minute of recovery. DHR_LAST_3—The difference between the heart rate since the last completed step to the 3 min of recovery.
FIGURE 3 Correlation between the variables of SmO2 and HR from the first minute of recovery to the 3 min of recovery. SmO2—The percentage of muscle oxygen saturation. HR—Heart Rate. DSMO2_LAST_1—The difference between the percentage of muscle oxygen saturation since the last completed step to the first recovery minute. DHR_LAST-1—The difference between the heart rate since the last completed step to the first recovery minute. DSMO2_LAST_3—The difference between the percentage of muscle oxygen saturation since the last completed step to the third minute of recovery. DHR_LAST_3—The difference between the heart rate since the last completed step to the 3 min of recovery.CC BY · PubMed Central

Verification

Claims the paper makes

4 Valid · 1 Not valid · 17 Not checked · 34 Own results and interpretations

17 more claims

Create a free account to see all 56 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 16
  • Probably not a substantial claim. 22
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 40 references

Research works printed but not linked: 1

  1. Corrales-Gil A. Hendrinkson-Gómez A. Coronel-Puchaeisela F. (2013). Reyes-Janeiro I. Valoración de la frecuencia cardíaca y el lactato durante el test escalonado en corredores de medio fondo. Rev. IMD 8 (1). Available at: http://www.revmedep.sld.cu/index.php/medep/article/view/219 (accessed at 06 16, 2022).

Cited by

See all 8

Metadata

Authors
Osmani, F., Lago-Fuentes, C., Alemany-Iturriaga, J., & Barcala-Furelos, M.
Affiliations
Universidad Europea del Atlántico (ES)
Corresponding author
Osmani, Florent
Venue
Frontiers in Physiology
Published
2023-05-18
Volume
14
Pages
1155037-1155037
ISSN
1664-042X (ISSN-L)
OpenAlex
W4377108297
Cited by
8
References
41
Citations by year
2026: 2 · 2025: 3 · 2024: 1 · 2023: 2
FWCI
1.22
Type
journal article
Language
en
Open access
Locations
  • Frontiers in Physiology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
muscle oxygen saturation, near-infrared spectroscopy, second ventilatory threshold, running performance, blood lactate, heart rate, perceived exertion, running power, vastus lateralis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-13, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-13 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test. https://app.cochat.ai/papers/10.3389/fphys.2023.1155037
The paper
Osmani, F., Lago-Fuentes, C., Alemany-Iturriaga, J., & Barcala-Furelos, M. (2023). The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test. Frontiers in Physiology. https://doi.org/10.3389/fphys.2023.1155037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.