EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 1: Basic Principles and Technology
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
The technical part of these Guidelines and Recommendations, produced under the auspices of EFSUMB, provides an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based. A difference in shear modulus is the common underlying physical mechanism that provides tissue contrast in all elastograms. The relationship between the alternative technologies is considered in terms of the method used to take advantage of this. The practical advantages and disadvantages associated with each of the techniques are described, and guidance is provided on optimisation of scanning technique, image display, image interpretation and some of the known image artefacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Castéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Self-citationShear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study
Foucher, J. (2006) · Gut · doi:10.1136/gut.2005.069153 · Cited by 1,284
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Diagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Piscaglia, F., Nolsøe, C., Dietrich, C., Cosgrove, D., Gilja, O., Bachmann Nielsen, M., Albrecht, T., Barozzi, L., Bertolotto, M., Catalano, O., et al. (2011) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0031-1281676 · Cited by 1,082
Self-citationClaudon, M., Dietrich, C. F., Choi, B. I., Cosgrove, D. O., Kudo, M., Nolsøe, C. P., Piscaglia, F., Wilson, S. R., Barr, R. G., Chammas, M. C., et al. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.002 · Cited by 971
Self-citationCosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Self-citation
Cited by
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
“Journal of Hepatology 201 based on two physical principles: strain displacement/imaging and shear wave imaging and quantification [88].”
BackgroundDietrich, C., Bamber, J., Berzigotti, A., Bota, S., Cantisani, V., Castera, L., Cosgrove, D., Ferraioli, G., Friedrich-Rust, M., Gilja, O., et al. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0043-103952 · Cited by 1,011
Self-citationShiina, T., Nightingale, K. R., Palmeri, M. L., Hall, T. J., Bamber, J. C., Barr, R. G., Castera, L., Choi, B. I., Chou, Y.-H., Cosgrove, D., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.009 · Cited by 958
Self-citationCosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Self-citationWFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 3: Liver
Ferraioli, G., Filice, C., Castera, L., Choi, B. I., Sporea, I., Wilson, S. R., Cosgrove, D., Dietrich, C. F., Amy, D., Bamber, J. C., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.007 · Cited by 879
Self-citationNonalcoholic fatty liver disease
Brunt, E. M., Wong, V. W.-S., Nobili, V., Day, C. P., Sookoian, S., Maher, J. J., Bugianesi, E., Sirlin, C. B., Neuschwander-Tetri, B. A., & Rinella, M. E. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.80 · Cited by 818
Barr, R. G., Ferraioli, G., Palmeri, M. L., Goodman, Z. D., Garcia-Tsao, G., Rubin, J., Garra, B., Myers, R. P., Wilson, S. R., Rubens, D., et al. (2015) · Radiology · doi:10.1148/radiol.2015150619 · Cited by 632
Noninvasive biomarkers in NAFLD and NASH — current progress and future promise
Wong, V. W.-S., Adams, L. A., de Lédinghen, V., Wong, G. L.-H., & Sookoian, S. (2018) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-018-0014-9 · Cited by 614
Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542
Herrmann, E., de Lédinghen, V., Cassinotto, C., Chu, W. C. ‐., Leung, V. Y. ‐., Ferraioli, G., Filice, C., Castera, L., Vilgrain, V., Ronot, M., et al. (2018) · Hepatology · doi:10.1002/hep.29179 · Cited by 468
Self-citationNon-invasive diagnosis of liver fibrosis and cirrhosis
Lurie, Y. (2015) · World Journal of Gastroenterology · doi:10.3748/wjg.v21.i41.11567 · Cited by 352
Ultrasound Elastography: The New Frontier in Direct Measurement of Muscle Stiffness
Brandenburg, J. E., Eby, S. F., Song, P., Zhao, H., Brault, J. S., Chen, S., & An, K.-N. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.07.007 · Cited by 327
Săftoiu, A., Gilja, O. H., Sidhu, P. S., Dietrich, C. F., Cantisani, V., Amy, D., Bachmann-Nielsen, M., Bob, F., Bojunga, J., Brock, M., et al. (2019) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0838-9937 · Cited by 320
Self-citationPrinciples of ultrasound elastography
Ozturk, A., Grajo, J. R., Dhyani, M., Anthony, B. W., & Samir, A. E. (2018) · Abdominal Radiology · doi:10.1007/s00261-018-1475-6 · Cited by 299
Current State of Breast Cancer Diagnosis, Treatment, and Theranostics
Bhushan, A., Gonsalves, A., & Menon, J. U. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13050723 · Cited by 298
Non-invasive evaluation of portal hypertension using ultrasound elastography
Berzigotti, A. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.02.003 · Cited by 271
WFUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography: Part 4. Thyroid
Cosgrove, D., Barr, R., Bojunga, J., Cantisani, V., Chammas, M. C., Dighe, M., Vinayak, S., Xu, J.-M., & Dietrich, C. F. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.06.022 · Cited by 259
Self-citationBarr, R. G., Cosgrove, D., Brock, M., Cantisani, V., Correas, J. M., Postema, A. W., Salomon, G., Tsutsumi, M., Xu, H.-X., & Dietrich, C. F. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.06.020 · Cited by 259
Self-citationCritical comparison of elastography methods to assess chronic liver disease
Friedrich-Rust, M., Poynard, T., & Castera, L. (2016) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2016.86 · Cited by 245
Self-citationTang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14552 · Cited by 216
“For these reasons, it can be used by clinicians at the point of service, which is a major advantage [23].”
Point of Care Ultrasound: A WFUMB Position Paper
Dietrich, C. F., Goudie, A., Chiorean, L., Cui, X. W., Gilja, O. H., Dong, Y., Abramowicz, J. S., Vinayak, S., Westerway, S. C., Nolsøe, C. P., et al. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.06.021 · Cited by 215
“Hepatologists and gastroenterologists increasingly perform their own liver ultrasound not only with B-mode but often also using elastography (Bamber et al. 2013; Barr et al. 2015; Cosgrove et al. 2013; Ferraioli et al. 2015; Shiina et al. 2015).”
Self-citationMarasco, G., Colecchia, A., Colli, A., Ravaioli, F., Casazza, G., Bacchi Reggiani, M. L., Cucchetti, A., Cescon, M., & Festi, D. (2019) · Journal of Hepatology · doi:10.1016/j.jhep.2018.10.022 · Cited by 200
Tang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14553 · Cited by 197
Noninvasive imaging biomarker assessment of liver fibrosis by elastography in NAFLD
Tapper, E. B., & Loomba, R. (2018) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2018.10 · Cited by 179
Nylund, K., Maconi, G., Hollerweger, A., Ripolles, T., Pallotta, N., Higginson, A., Serra, C., Dietrich, C., Sporea, I., Saftoiu, A., et al. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0042-115853 · Cited by 163
“An overview of the different techniques and applications has been published by EFSUMB [3, 5].”
MethodSelf-citationMagnetic resonance elastography from fundamental soft-tissue mechanics to diagnostic imaging
Sack, I. (2022) · Nature Reviews Physics · doi:10.1038/s42254-022-00543-2 · Cited by 162
Sonography of the penis/erectile dysfunction
Bertolotto, M., Campo, I., Sachs, C., Ciabattoni, R., Bucci, S., Cova, M. A., & Van Nieuwenhove, S. (2020) · Abdominal Radiology · doi:10.1007/s00261-020-02529-z · Cited by 21
Metadata
- Authors
- Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., Fink, M., Friedrich-Rust, M., Gilja, O., Havre, R., Jenssen, C., Klauser, A., Ohlinger, R., Saftoiu, A., Schaefer, F., Sporea, I., & Piscaglia, F.
- Venue
- Ultraschall in der Medizin - European Journal of Ultrasound
- Publisher
- Georg Thieme Verlag KG
- Published
- 2013-04-04
- Volume
- 34
- Issue
- 02
- Pages
- 169-184
- ISSN
- 0172-4614 (ISSN-L)
- 1438-8782
- OpenAlex
- W2027622024
- Cited by
- 1,198
- References
- 41
- FWCI
- 70.35
- Type
- journal article
- Language
- de
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.