CoChat

Analysis of Square-wave Bouts to Verify VO2max

Sedgeman, D., Dalleck, L., Clark, I., Jamnick, N., Pettitt, R. · 2013 · International Journal of Sports Medicine
Cited by 35

The DOI matches its Crossref record.

Abstract

Submaximal and supramaximal square-wave bouts have been reported to consistently verify 'true' VO2max. Although a direct comparison between both protocols exists, knowledge on the statistical consistency between the protocols using the same group of participants is lacking. The purpose of this study was to conduct an analysis of the submaximal and supramaximal verification bout performed shortly subsequent to a graded exercise test (GXT). On 2 separate occasions, 6 males and 7 females (age: 29±9 years) completed a GXT protocol and an exhaustive, square-wave bout at either end-GXT power minus 2-stages or 105% end-GXT power. No differences (p>0.05) in VO2max were observed between the GXT and square-wave bouts. The typical error (ml/kg/min) for submaximal (1.09) and supramaximal (1.04) trials was similar. Likewise, similar relative measures of consistency were observed for the submaximal (ICC α=0.97, CV=2.4%) and supramaximal trials (ICC α=0.95, CV=2.3%). For a GXT lasting ~10-12 min, the submaximal or supramaximal protocols appear to be equally effective.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0033-1341436

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sedgeman, D., Dalleck, L., Clark, I., Jamnick, N., & Pettitt, R.
Venue
International Journal of Sports Medicine
Published
2013-06-05
Volume
34
Issue
12
Pages
1058-1062
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W2328016772
Cited by
35
References
0
FWCI
3.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.