CoChat

The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.

Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type

Open access
Idakoji, Ibrahim, Kuo, William, Deso, Steven · 2016 · Seminars in Interventional Radiology

Abstract

Many inferior vena cava (IVC) filter types, along with their specific risks and complications, are not recognized. The purpose of this study was to evaluate the various FDA-approved IVC filter types to determine device-specific risks, as a way to help identify patients who may benefit from ongoing follow-up versus prompt filter retrieval. An evidence-based electronic search (FDA Premarket Notification, MEDLINE, FDA MAUDE) was performed to identify all IVC filter types and device-specific complications from 1980 to 2014. Twenty-three IVC filter types (14 retrievable, 9 permanent) were identified. The devices were categorized as follows: conical (n = 14), conical with umbrella (n = 1), conical with cylindrical element (n = 2), biconical with cylindrical element (n = 2), helical (n = 1), spiral (n = 1), and complex (n = 1). Purely conical filters were associated with the highest reported risks of penetration (90-100%). Filters with cylindrical or umbrella elements were associated with the highest reported risk of IVC thrombosis (30-50%). Conical Bard filters were associated with the highest reported risks of fracture (40%). The various FDA-approved IVC filter types were evaluated for device-specific complications based on best current evidence. This information can be used to guide and optimize clinical management in patients with indwelling IVC filters.

Overview

Integrity signals

Registry

Crossref · 10.1055/s-0036-1583208

Cites

90 of 90 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 90 references

Cited by

See all 97

Metadata

Authors
Idakoji, I., Kuo, W., & Deso, S.
Affiliations
Stanford Medicine (US)
Corresponding author
Deso, Steven
Venue
Seminars in Interventional Radiology
Published
2016-05-10
Volume
33
Issue
02
Pages
093-100
ISSN
  • 0739-9529 (ISSN-L)
  • 1098-8963
OpenAlex
W2415693239
Cited by
93
References
90
Citations by year
2026: 11 · 2025: 4 · 2024: 11 · 2023: 9 · 2022: 10 · 2021: 10 · 2020: 16 · 2019: 12 · 2018: 6 · 2017: 3 · 2016: 1
FWCI
1.31
Type
journal article
Language
en
Open access
Locations
  • Seminars in Interventional Radiology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Tufts University School of Medicine
Topics
  • Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
  • Health Sciences › Medicine › Surgery › Vascular anomalies and interventions
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
Keywords
inferior vena cava filter, IVC filter complications, filter type, inferior vena cava thrombosis, filter fracture, filter retrieval, FDA-approved devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type. https://app.cochat.ai/papers/10.1055/s-0036-1583208
The paper
Idakoji, I., Kuo, W., & Deso, S. (2016). Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type. Seminars in Interventional Radiology. https://doi.org/10.1055/s-0036-1583208

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.