Robotic arm-assisted total knee arthroplasty (RATKA) presents a potential, new added value for orthopedic surgeons. In today's health care system, a major determinant of value can be assessed by patient satisfaction scores. Therefore, the purpose of the study was to analyze patient satisfaction outcomes between RATKA and manual total knee arthroplasty (TKA). Specifically, we used the Western Ontario and McMaster Universities Arthritis Index (WOMAC) to compare (1) pain scores, (2) physical function scores, and (3) total patient satisfaction outcomes in manual and RATKA patients at 6 months postoperatively. In this study, 28 cemented RATKAs performed by a single orthopedic surgeon at a high-volume institution were analyzed. The first 7 days were considered as an adjustment period along the learning curve. Twenty consecutive cemented RATKAs were matched and compared with 20 consecutive cemented manual TKAs performed immediately. Patients were administered a WOMAC satisfaction survey at 6 months postoperatively. Satisfaction scores between the two cohorts were compared and the data were analyzed using Student's t-tests. A p-value < 0.05 was used to determine statistical significance. The mean pain score, standard deviation (SD), and range for the manual and robotic cohorts were 5 ± 3 (range: 0–10) and 3 ± 3 (range: 0–8, p < 0.05), respectively. The mean physical function score, SD, and range for the manual and robotic cohorts were 9 ± 5 (range: 0–17) and 4 ± 5 (range, 0–14, p = 0.055), respectively. The mean total patient satisfaction score, SD, and range for the manual and robotic cohorts were 14 points (range: 0–27 points, SD: ± 8) and 7 ± 8 points (range: 0–22 points, p < 0.05), respectively. The results from this study further highlight the potential of this new surgical tool to improve short-term pain, physical function, and total satisfaction scores. Therefore, it appears that patients who undergo RATKA can expect better short-term outcomes when compared with patients who undergo manual TKA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Song, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Cobb, J., Henckel, J., Gomes, P., Harris, S., Jakopec, M., Rodriguez, F., Barrett, A., & Davies, B. (2006) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.88b2.17220 · Cited by 333
Alignment in total knee replacement
Sikorski, J. M. (2008) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.90b9.20793 · Cited by 276
Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications
Cherian, J. J., Kapadia, B. H., Banerjee, S., Jauregui, J. J., Issa, K., & Mont, M. A. (2014) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-014-9218-y · Cited by 274
Self-citationSong, E., Seon, J., Park, S., Jung, W. B., Park, H., & Lee, G. W. (2011) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1400-9 · Cited by 268 · cited 2×
“Song et al 29 also performed another study with 30 patients who underwent bilateral sequential total knee replacement with one knee operated on using the robotic device and the other using the manual technique.”
Liow, M. H. L., Goh, G. S.-H., Wong, M. K., Chin, P. L., Tay, D. K. J., & Yeo, S.-J. (2016) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-016-4076-3 · Cited by 226
van der List, J. P., Chawla, H., Joskowicz, L., & Pearle, A. D. (2016) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4305-9 · Cited by 200
Mechanical and kinematic alignment in total knee arthroplasty
Schiraldi, M., Bonzanini, G., Chirillo, D. F., & Tullio, V. D. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.03.31 · Cited by 121 · cited 3×
“8 – 10 Although mechanical axis alignment is important for long-term functionality and implant survivorship, 11 – 14 it is unknown whether the improved positioning achieved using robotic technology is superior to manual techniques in terms of patient outcomes.”
What Influences How Patients Rate Their Hospital After Total Hip Arthroplasty?
Mistry, J. B., Chughtai, M., Elmallah, R. K., Le, S., Bonutti, P. M., Delanois, R. E., & Mont, M. A. (2016) · The Journal of Arthroplasty · doi:10.1016/j.arth.2016.03.060 · Cited by 76
Self-citationZelhart, M. D., & Kaiser, A. M. (2017) · Surgical Endoscopy · doi:10.1007/s00464-017-5796-2 · Cited by 63
Cited by
Robotic Arm–Assisted Total Knee Arthroplasty
Khlopas, A., Sodhi, N., Sultan, A. A., Chughtai, M., Molloy, R. M., & Mont, M. A. (2018) · The Journal of Arthroplasty · doi:10.1016/j.arth.2018.01.060 · Cited by 174
Self-citation
Metadata
- Authors
- Marchand, R., Sodhi, N., Khlopas, A., Sultan, A., Harwin, S., Malkani, A., & Mont, M.
- Venue
- The Journal of Knee Surgery
- Publisher
- Georg Thieme Verlag KG
- Published
- 2017-10-13
- Volume
- 30
- Issue
- 09
- Pages
- 849-853
- ISSN
- 1538-8506 (ISSN-L)
- 1938-2480
- OpenAlex
- W2761803242
- Cited by
- 195
- References
- 13
- FWCI
- 12.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient Satisfaction Outcomes after Robotic Arm-Assisted Total Knee Arthroplasty: A Short-Term Evaluation. https://app.cochat.ai/papers/10.1055/s-0037-1607450
- The paper
- Marchand, R., Sodhi, N., Khlopas, A., Sultan, A., Harwin, S., Malkani, A., & Mont, M. (2017). Patient Satisfaction Outcomes after Robotic Arm-Assisted Total Knee Arthroplasty: A Short-Term Evaluation. The Journal of Knee Surgery. https://doi.org/10.1055/s-0037-1607450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.