The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study
Abstract
Purpose: The authors performed this study to compare the outcomes of robotic‐assisted and conventional TKA in same patient simultaneously. It was hypothesized that the robotic‐assisted procedure would produce better leg alignment and component orientation, and thus, improve patient satisfaction and clinical and radiological outcomes. Methods: Thirty patients underwent bilateral sequential total knee replacement. One knee was replaced by robotic‐assisted implantation and the other by conventional implantation. Results: Radiographic results showed significantly more postoperative leg alignment outliers of conventional sides than robotic‐assisted sides (mechanical axis, coronal inclination of the femoral prosthesis, and sagittal inclination of the tibial prosthesis). Robotic‐assisted sides had non‐significantly better postoperative knee scores and ROMs. Robotic‐assisted sides needed longer operation times (25 min, SD ± 18) and longer skin incisions. Nevertheless, postoperative bleeding was significantly less for robotic‐assisted sides. Conclusion: The better alignment accuracy of robotic TKA and the good clinical results achieved may favorably influence clinical and radiological outcomes. Level of evidence: I.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
Computer Assisted Knee Replacement
Delp, S. L., Stulberg, D. S., Davies, B., Picard, F., & Leitner, F. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00007 · Cited by 336
Total Condylar Knee Replacement: A 20-Year Followup Study
Rodriguez, J. A., Bhende, H., & Ranawat, C. S. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200107000-00004 · Cited by 332
Technique and first clinical results of robot-assisted total knee replacement
Siebert, W., Mai, S., Kober, R., & Heeckt, P. F. (2002) · The Knee · doi:10.1016/s0968-0160(02)00015-7 · Cited by 281
Ten-Year Evaluation of Geometric Total Knee Arthroplasty
RAND, J. A., & COVENTRY, M. B. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198807000-00022 · Cited by 276
Park, S. E., & Lee, C. T. (2007) · The Journal of Arthroplasty · doi:10.1016/j.arth.2007.05.036 · Cited by 235
Self-citationConsistency of Implantation of a Total Knee Arthroplasty with a Non–Image-Based Navigation System
Jenny, J.-Y., Clemens, U., Kohler, S., Kiefer, H., Konermann, W., & Miehlke, R. K. (2005) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.02.002 · Cited by 229
Robot-assisted Total Knee Arthroplasty
Bellemans, J., Vandenneucker, H., & Vanlauwe, J. (2007) · Clinical Orthopaedics & Related Research · doi:10.1097/blo.0b013e318126c0c0 · Cited by 178
Lützner, J., Krummenauer, F., Wolf, C., Günther, K. ‐., & Kirschner, S. (2008) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.90b8.20553 · Cited by 135
Cited by
Song, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Self-citationKayani, B., Konan, S., Huq, S. S., Tahmassebi, J., & Haddad, F. S. (2019) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-018-5138-5 · Cited by 338
Liow, M. H. L., Xia, Z., Wong, M. K., Tay, K. J., Yeo, S. J., & Chin, P. L. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.12.010 · Cited by 265
van der List, J. P., Chawla, H., Joskowicz, L., & Pearle, A. D. (2016) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4305-9 · Cited by 200
Metadata
- Authors
- Song, E., Seon, J., Park, S., Jung, W. B., Park, H., & Lee, G. W.
- Venue
- Knee Surgery, Sports Traumatology, Arthroscopy
- Publisher
- Wiley
- Published
- 2011-02-11
- Volume
- 19
- Issue
- 7
- Pages
- 1069-1076
- ISSN
- 0942-2056 (ISSN-L)
- 1433-7347
- OpenAlex
- W2095851869
- Cited by
- 268
- References
- 10
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. https://app.cochat.ai/papers/10.1007/s00167-011-1400-9
- The paper
- Song, E., Seon, J., Park, S., Jung, W. B., Park, H., & Lee, G. W. (2011). Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-011-1400-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.