Determining Inappropriate Medication Alerts from “Inaccurate Warning” Overrides in the Intensive Care Unit
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Objective This article aims to understand provider behavior around the use of the override reason “Inaccurate warning,” specifically whether it is an effective way of identifying unhelpful medication alerts. Materials and Methods We analyzed alert overrides that occurred in the intensive care units (ICUs) of a major academic medical center between June and November 2016, focused on the following high-significance alert types: dose, drug-allergy alerts, and drug–drug interactions (DDI). Override appropriateness was analyzed by two independent reviewers using predetermined criteria. Results A total of 268 of 26,501 ICU overrides (1.0%) used the reason “Inaccurate warning,” with 93 of these overrides associated with our included alert types. Sixty-one of these overrides (66%) were identified to be appropriate. Twenty-one of 30 (70%) dose alert overrides were appropriate. Forty of 48 drug-allergy alert overrides (83%) were appropriate, for reasons ranging from prior tolerance (n = 30) to inaccurate ingredient matches (n = 5). None of the 15 DDI overrides were appropriate. Conclusion The “Inaccurate warning” reason was selectively used by a small proportion of providers and overrides using this reason identified important opportunities to reduce excess alerts. Potential opportunities include improved evaluation of dosing mechanisms based on patient characteristics, inclusion of institutional dosing protocols to alert logic, and evaluation of a patient's prior tolerance to a medication that they have a documented allergy for. This resource is not yet routinely used for alert tailoring at our institution but may prove to be a valuable resource to evaluate available alerts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bates, D. W., Kuperman, G. J., Wang, S., Gandhi, T., Kittler, A., Volk, L., Spurr, C., Khorasani, R., Tanasijevic, M., & Middleton, B. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1370 · Cited by 1,346
Self-citationThe Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Self-citationMedication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763
Self-citationwith the HITEC Investigators, Ancker, J. S., Edwards, A., Nosal, S., Hauser, D., Mauer, E., & Kaushal, R. (2017) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-017-0430-8 · Cited by 709
Physicians' Decisions to Override Computerized Drug Alerts in Primary Care
Weingart, S. N., Toth, M., Sands, D. Z., Aronson, M. D., Davis, R. B., & Phillips, R. S. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.21.2625 · Cited by 487
The Epidemiology of Prescribing Errors: The Potential Impact of Computerized Prescriber Order Entry
Bobb, A., Gleason, K., Husch, M., Feinglass, J., Yarnold, P. R., & Noskin, G. A. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.7.785 · Cited by 359
Tiering Drug-Drug Interaction Alerts by Severity Increases Compliance Rates
Paterno, M. D., Maviglia, S. M., Gorman, P. N., Seger, D. L., Yoshida, E., Seger, A. C., Bates, D. W., & Gandhi, T. K. (2009) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2808 · Cited by 263
Self-citationHsieh, T. C., Kuperman, G. J., Jaggi, T., Hojnowski-Diaz, P., Fiskio, J., Williams, D. H., Bates, D. W., & Gandhi, T. K. (2004) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1556 · Cited by 232
Self-citationOverrides of medication-related clinical decision support alerts in outpatients
Nanji, K. C., Slight, S. P., Seger, D. L., Cho, I., Fiskio, J. M., Redden, L. M., Volk, L. A., & Bates, D. W. (2014) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2013-001813 · Cited by 219
Self-citationLin, C.-P., Payne, T. H., Nichol, W. P., Hoey, P. J., Anderson, C. L., & Gennari, J. H. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2453 · Cited by 110
Improving medication-related clinical decision support
Tolley, C. L., Slight, S. P., Husband, A. K., Watson, N., & Bates, D. W. (2018) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp160830 · Cited by 105
Self-citationWong, A., Amato, M. G., Seger, D. L., Rehr, C., Wright, A., Slight, S. P., Beeler, P. E., Orav, E. J., & Bates, D. W. (2018) · BMJ Quality & Safety · doi:10.1136/bmjqs-2017-007531 · Cited by 77
Self-citation
Cited by
Appropriateness of Overridden Alerts in Computerized Physician Order Entry: Systematic Review
Poly, T. N., Islam, M. M., Yang, H.-C., & Li, Y.-C. (. (2020) · JMIR Medical Informatics · doi:10.2196/15653 · Cited by 118
“0 Dose, DDI, DAI June 2016November 2016 ICU POS Rehr et al [8]”
BackgroundInfluentialStructured override reasons for drug-drug interaction alerts in electronic health records
Wright, A., McEvoy, D. S., Aaron, S., McCoy, A. B., Amato, M. G., Kim, H., Ai, A., Cimino, J. J., Desai, B. R., El-Kareh, R., et al. (2019) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocz033 · Cited by 61
Elias, P., Peterson, E., Wachter, B., Ward, C., Poon, E., & Navar, A. M. (2019) · Applied Clinical Informatics · doi:10.1055/s-0039-1700869 · Cited by 33
Kitzmiller, R., Vaughan, A., Skeeles-Worley, A., Keim-Malpass, J., Yap, T., Lindberg, C., Kennerly, S., Mitchell, C., Tai, R., Sullivan, B., et al. (2019) · Applied Clinical Informatics · doi:10.1055/s-0039-1688478 · Cited by 25
Knight, A. M., Maygers, J., Foltz, K. A., John, I. S., Yeh, H. C., & Brotman, D. J. (2019) · Applied Clinical Informatics · doi:10.1055/s-0039-3400447 · Cited by 22
Metadata
- Authors
- Rehr, C., Wong, A., Seger, D., & Bates, D.
- Venue
- Applied Clinical Informatics
- Publisher
- Georg Thieme Verlag KG
- Published
- 2018-04
- Volume
- 09
- Issue
- 02
- Pages
- 268-274
- ISSN
- 1869-0327 (ISSN-L)
- OpenAlex
- W2802050075
- Cited by
- 24
- References
- 12
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.