A Higher than Expected Incidence of Factor VIII Inhibitors in Multitransfused Haemophilia A Patients Treated with an Intermediate Purity Pasteurized Factor VIII Concentrate
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Summary: In May 1990, 218 patients with haemophilia A regularly attending the Leuven Haemophilia Center were randomly assigned to a group receiving either of two newly introduced factor VIII concentrates: factor VIII-P, an intermediate purity pasteurized concentrate, or factor VIII-SD, a high purity concentrate treated with solvent-detergent for viral inactivation. Patients were followed from May 1990 until October 1991. Between August 1991 and October 1991 a clinically important factor VIII inhibitor was detected in five out of the 109 patients receiving factor VIII-P while none of the 109 patients receiving factor VIII-SD developed such antibodies. All patients acquiring an inhibitor had previously been clinically tolerant to transfused factor VIII with 200 to more than 1,000 days of exposure to factor VIII prior to May 1990. Patients with inhibitors were transfused daily with 30 U factor VIII-SD per kg body weight, which was associated with a gradual decline of the inhibitor level. In all patients the antibodies were relatively slow-acting and predominantly directed towards the light chain of factor VIII. This study demonstrates a higher than expected incidence of factor VIII inhibitors associated with the use of a specific factor VIII concentrate in multitransfused haemophilia A patients. It indicates the usefulness of evaluating newly introduced concentrates in prospective, randomized trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langdell, R. D., Wagner, R. H., & Brinkhous, K. M. (1953) · PubMed · Cited by 852
Human Recombinant DNA–Derived Antihemophilic Factor (Factor VIII) in the Treatment of Hemophilia A
Schwartz, R. S., Abildgaard, C. F., Aledort, L. M., Arkin, S., Bloom, A. L., Brackmann, H. H., Brettler, D. B., Fukui, H., Hilgartner, M. W., Inwood, M. J., et al. (1990) · New England Journal of Medicine · doi:10.1056/nejm199012273232604 · Cited by 267
Rosendaal, F., Nieuwenhuis, H., van den Berg, H., Heijboer, H., Mauser- Bunschoten, E., van der Meer, J., Smit, C., Strengers, P., & Briet, E. (1993) · Blood · doi:10.1182/blood.v81.8.2180.2180 · Cited by 194
McMillan, C., Shapiro, S., Whitehurst, D., Hoyer, L., Rao, A., & Lazerson, J. (1988) · Blood · doi:10.1182/blood.v71.2.344.344 · Cited by 169
Schwarzinger, I., Pabinger, I., Korninger, C., Haschke, F., Kundi, M., Niessner, H., & Lechner, K. (1987) · American Journal of Hematology · doi:10.1002/ajh.2830240303 · Cited by 74 · cited 3×
“Remarkably, the number of exposure days to factor VIII-P before the detection of inhibitor ranged from 98 to 170 days (mean 134) (Table 2) which is longer than what has been reported for previously untreated patients (3, 4).”
Burnouf, T., Burnouf, T., Huart, J. J., & Goudemand, M. (1991) · Vox Sanguinis · doi:10.1111/j.1423-0410.1991.tb00864.x · Cited by 67 · cited 1×
“3% tri[n-butyl]phosphate 1% polysorbate 80) (Biotransfusion, Lille, France) (8).”
Haemophiliacs with factor VIII inhibitors in Finland: prevalence, incidence and outcome
Rasi, V., & Ikkala, E. (1990) · British Journal of Haematology · doi:10.1111/j.1365-2141.1990.tb06370.x · Cited by 62 · cited 1×
“SchattauerVerlagsgesellschaft mbH (Stuttgart) 69 (2) 115-118 (1993)”
Epidemic of Factor VIII Inhibitors Linked to Factor VIII-P
Vermylen, J., & Peerlinck, K. (1991) · Acta Clinica Belgica · doi:10.1080/17843286.1991.11718201 · Cited by 10 · cited 2×
“In a study with human recombinant factor VIII only 1 of 81 previously multi transfused patients developed an inhibitor (14).”
Self-citation
Cited by
Protein Therapeutics: A Summary and Pharmacological Classification
Leader, B., Baca, Q. J., & Golan, D. E. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2399 · Cited by 2,161
Verbruggen, B., Novakova, I., Wessels, H., Boezeman, J., van den Berg, M., & Mauser-Bunschoten, E. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1653759 · Cited by 652
The epidemiology of inhibitors in haemophilia A: a systematic review
Wight, J., & Paisley, S. (2003) · Haemophilia · doi:10.1046/j.1365-2516.2003.00780.x · Cited by 627
KEELING, D., TAIT, C., & MAKRIS, M. (2008) · Haemophilia · doi:10.1111/j.1365-2516.2008.01695.x · Cited by 258
Scharrer, Bray, & Neutzling (1999) · Haemophilia · doi:10.1046/j.1365-2516.1999.00300.x · Cited by 200
Metadata
- Authors
- Peerlinck, K., Arnout, J., Gilles, J. G., Saint-Remy, J.-M., & Vermylen, J.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1993
- Volume
- 69
- Issue
- 02
- Pages
- 115-118
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W1730534368
- Cited by
- 181
- References
- 8
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.