Comparison of Thrombelastography with Common Coagulation Tests
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Thrombelastography, although proven as a useful research tool has not been evaluated for its clinical utility against common coagulation laboratory tests. In this study we compare the thrombelastographic measurements with six common tests (the hematocrit, platelet count, fibrinogen, prothrombin time, activated thromboplastin time and fibrin split products). For such comparisons, two samples of subjects were selected, 141 normal volunteers and 121 patients with cancer. The data was subjected to various statistical techniques such as correlation, ANOVA, canonical and discriminant analysis to measure the extent of the correlations between the two sets of variables and their relative strength to detect blood clotting abnormalities. The results indicate that, although there is a strong relationship between the thrombelastographic variables and these common laboratory tests, the thrombelastographic variables contain additional information on the hemostatic process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multivariate Statistical Methods
(2008) · Encyclopedia of Public Health · doi:10.1007/978-1-4020-5614-7_2263 · Cited by 5,580
Gerinnungsphysiologische Schnellmethode zur Bestimmung des Fibrinogens
Clauss, A. (1957) · Acta Haematologica · doi:10.1159/000205234 · Cited by 3,208
BMDP-77, Biomedical Computer Programs, P-Series
Anderson, G. D., Dixon, W. J., & Brown, M. B. (1979) · The Canadian Journal of Statistics / La Revue Canadienne de Statistique · doi:10.2307/3315023 · Cited by 772
Cited by
Guidelines for the diagnosis and management of disseminated intravascular coagulation
Levi, M., Toh, C. H., Thachil, J., & Watson, H. G. (2009) · British Journal of Haematology · doi:10.1111/j.1365-2141.2009.07600.x · Cited by 1,119
Kang, Y. G., Martin, D. J., Marquez, J., Lewis, J. H., Bontempo, F. A., Shaw, B. W., Starzl, T. E., & Winter, P. M. (1985) · Anesthesia & Analgesia · doi:10.1213/00000539-198509000-00008 · Cited by 684
Thrombelastography/thromboelastometry
LUDDINGTON, R. J. (2005) · Clinical and Laboratory Haematology · doi:10.1111/j.1365-2257.2005.00681.x · Cited by 655
Disseminated intravascular coagulation
Gando, S., Levi, M., & Toh, C.-H. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.37 · Cited by 572
Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography
RUGERI, L., LEVRAT, A., DAVID, J. S., DELECROIX, E., FLOCCARD, B., GROS, A., ALLAOUCHICHE, B., & NEGRIER, C. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02319.x · Cited by 491
Bolliger, D., Seeberger, M. D., & Tanaka, K. A. (2012) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2011.07.005 · Cited by 397
Coagulopathy: Its Pathophysiology and Treatment in the Injured Patient
Tieu, B. H., Holcomb, J. B., & Schreiber, M. A. (2007) · World Journal of Surgery · doi:10.1007/s00268-006-0653-9 · Cited by 255
Plotkin, A. J., Wade, C. E., Jenkins, D. H., Smith, K. A., Noe, J. C., Park, M. S., Perkins, J. G., & Holcomb, J. B. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e318160772d · Cited by 216
“TEG measures the entire process of the clotting cascade, from initial clot formation through complete clot lysis.(17) Currently, the initial results of a TEG are available in 10 minutes to 15 minutes, excluding fibrinolysis data, whereas PT and PTT, because of the logistical restraints of hospital laboratories, requir…”
MethodPostinjury Coagulopathy Management: Goal Directed Resuscitation via POC Thrombelastography
Kashuk, J. L., Moore, E. E., Sawyer, M., Le, T., Johnson, J., Biffl, W. L., Cothren, C. C., Barnett, C., Stahel, P., Sillman, C. C., et al. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181d3599c · Cited by 209
Ben-Ari, Z., Panagou, M., Patch, D., Bates, S., Osman, E., Pasi, J., & Burroughs, A. (1997) · Journal of Hepatology · doi:10.1016/s0168-8278(97)80420-5 · Cited by 186
Essell, J. H., Martin, T. J., Salinas, J., Thompson, J. M., & Smith, V. C. (1993) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(93)90161-d · Cited by 164
Influence of coconut water on hemostasis
Pummer, S., Heil, P., Maleck, W., & Petroianu, G. (2001) · The American Journal of Emergency Medicine · doi:10.1053/ajem.2001.24477 · Cited by 48
Metadata
- Authors
- Zuckerman, L., Cohen, E., Vagher, J. P., Woodward, E., & Caprini, J. A.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1981
- Volume
- 46
- Issue
- 04
- Pages
- 752-756
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2417660540
- Cited by
- 227
- References
- 3
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.