Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record.

A Reduction in Clot Formation Rate and Strength Assessed by Thrombelastography Is Indicative of Transfusion Requirements in Patients With Penetrating Injuries

Plotkin, Amy J., Wade, Charles E., Jenkins, Donald H., Smith, Kimberly A., Noe, Jody C., Park, Myung S., Perkins, Jeremy G., Holcomb, John B.·2008·Journal of Trauma: Injury, Infection & Critical Care

Abstract

BACKGROUND: Bleeding is a major cause of death in patients with traumatic injuries. Recently, thrombelastography (TEG) has been suggested as an additional means of evaluating coagulation in trauma patients. We hypothesized that TEG data would aid in defining the coagulopathy of trauma in patients with penetrating traumatic injuries. METHODS: A retrospective study was performed of patients (n = 44) with penetrating injuries admitted to a combat support hospital during a 2-month period in 2004. Recorded data included standard laboratory data, TEG parameters, and blood product use in the first 24 hours after admission. Values were compared with clinically accepted ranges and those obtained from the Haemoscope Corporation. RESULTS: At admission, International Normalization Ratio, prothrombin time, and partial thromboplastin time were increased in 39% (>or=1.5), 31% (>16 seconds), and 37% (>40 seconds) of patients, respectively, suggesting hypocoagulation, but these variables did not correlate with the use of blood products (p > 0.05). TEG values obtained within 24 hours of admission (6 hours +/- 5.7 hours; median of 4.5 hours) demonstrated hypocoagulation based on delayed propagation of the clot (increased K time and reduced alpha-angle) and decreased clot strength (reduced maximal amplitude [MA]). MA correlated (r = 0.57, p < 0.01) with blood product use as well as platelet count (r = 0.61, p < 0.01). Patients with reduced MA (n = 23) used more blood products and had reduced platelet counts and hematocrit. CONCLUSION: Thrombelastography was a more accurate indicator of blood product requirements in our patient population than prothrombin time, partial thromboplastin time, and International Normalization Ratio. Thrombelastography enhanced by platelet count and hematocrit can guide blood transfusion requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ta.0b013e318160772d

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
Plotkin, A. J., Wade, C. E., Jenkins, D. H., Smith, K. A., Noe, J. C., Park, M. S., Perkins, J. G., & Holcomb, J. B.
Venue
Journal of Trauma: Injury, Infection & Critical Care
Published
2008-02
Volume
64
Issue
2
Pages
S64-S68
ISSN
0022-5282 (ISSN-L)
OpenAlex
W1969720423
Cited by
216
References
0
FWCI
18.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Reduction in Clot Formation Rate and Strength Assessed by Thrombelastography Is Indicative of Transfusion Requirements in Patients With Penetrating Injuries. https://app.cochat.ai/papers/10.1097/ta.0b013e318160772d
The paper
Plotkin, A. J., Wade, C. E., Jenkins, D. H., Smith, K. A., Noe, J. C., Park, M. S., Perkins, J. G., & Holcomb, J. B. (2008). A Reduction in Clot Formation Rate and Strength Assessed by Thrombelastography Is Indicative of Transfusion Requirements in Patients With Penetrating Injuries. Journal of Trauma: Injury, Infection & Critical Care. https://doi.org/10.1097/ta.0b013e318160772d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.