Multicenter Evaluation of Nine Commercial Kits for the Quantitation of Anticardiolipin Antibodies
The DOI matches its Crossref record.
Abstract
Summary: The performances of nine commercial kits and an in-house method (HM) for the quantitation of anticardiolipin antibodies (ACA) have been evaluated in a multicenter study. Ninety control and patient samples and six standards from Louisville University were run with kits and with the HM. Marked differences in positivity rate between kits were observed, ranging from 31 to 60% for IgG and 6 to 50% for IgM. Concordance between kits occurred in 59 and 51% of samples for IgG and IgM respectively. Concordance coefficients (kappa) ranged from 0.13 to 0.92. Slopes of regression lines between the declared units of Louisville standards and the units measured from the calibrators of the kits showed great diversity and ranged from 0.159 to 0.931 for IgG and from 0.236 to 0.836 for IgM. The β2-glycoprotein I (β2-GPI) content of the dilution buffers and the wells supplied with the kits revealed noticeable differences. However samples containing anti-(β2-GPI antibodies were classified similarly by all but one kit. In contrast the ability to measure samples devoid of anti-β2-GPI antibodies differed markedly between the kits. This study shows that differences in positivity rates between the commercial kits may contribute to the differences in ACA prevalence rate found in the literature. The choice of cut-off levels may partly explain the moderate concordance between the kits. In addition some samples behave very differently depending on the kits. In spite of the expression of results in PL units, standardization of ACA assays has not been achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MIYAKIS, S., LOCKSHIN, M. D., ATSUMI, T., BRANCH, D. W., BREY, R. L., CERVERA, R., DERKSEN, R. H. W. M., DE GROOT, P. G., KOIKE, T., MERONI, P. L., et al. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01753.x · Cited by 7,203
Self-citationAntiphospholipid antibodies and thrombosis
Greaves, M. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10362-8 · Cited by 309
Management of the obstetric antiphospholipid syndrome
Derksen, R. H. W. M., Khamashta, M. A., & Branch, D. W. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20105 · Cited by 202
Wahl, D. G., Guillemin, F., de Maistre, E., Perret-Guillaume, C., Lecompte, T., & Thibaut, G. (1998) · Lupus · doi:10.1191/096120398678919688 · Cited by 185
Pierangeli, S., Groot, P. D., Dlott, J., Favaloro, E., Harris, E., Lakos, G., Ortel, T., Meroni, P., Otomo, K., Pengo, V, et al. (2011) · Lupus · doi:10.1177/0961203310395055 · Cited by 180
Bouvier, S., Cochery-Nouvellon, É., Lavigne-Lissalde, G., Mercier, É., Marchetti, T., Balducchi, J.-P., Marès, P., & Gris, J.-C. (2014) · Blood · doi:10.1182/blood-2013-08-522623 · Cited by 178
“Plasma aCL-G and aCL-Mantibody titers were determined by an adaptation10 of the inhouse enzyme-linked immunosorbent assay method described by Reber et al.11 Plasma ab2GP1-G and ab2GP1-M antibody titers were determined by an enzyme-linked immunosorbent assay developed in-house10 based on b2-glycoprotein I isolated from…”
MethodInfluentialCuadrado, M. J., Khamashta, M. A., Ballesteros, A., Godfrey, T., Simon, M. J., & V. Hughes, G. R. (2000) · Medicine · doi:10.1097/00005792-200001000-00006 · Cited by 168
Diagnostic Testing for Coagulopathies in Patients With Ischemic Stroke
Bushnell, C. D., & Goldstein, L. B. (2000) · Stroke · doi:10.1161/01.str.31.12.3067 · Cited by 166
The potential role of heparin in assisted conception
Nelson, S. M., & Greer, I. A. (2008) · Human Reproduction Update · doi:10.1093/humupd/dmn031 · Cited by 160
“, 2006), the diagnosis is difficult as it is dependent on only one clinical event and only one laboratory marker (Table V) with the latter poorly standardized, particularly if titres are weak (Brandt et al., 1995; Reber et al., 1995).”
BackgroundLaboratory diagnosis of the antiphospholipid syndrome: a plethora of obstacles to overcome
Devreese, K., & Hoylaerts, M. F. (2009) · European Journal Of Haematology · doi:10.1111/j.1600-0609.2009.01243.x · Cited by 78
Montaruli, B., De Luna, E., Mengozzi, G., Molinari, F., Napolitano, E., Napoli, P., Nicolo, C., Romito, A., Stella, S., Bazzan, M., et al. (2012) · Lupus · doi:10.1177/0961203312442260 · Cited by 16
Metadata
- Authors
- Reber, G., Arvieux, J., Comby, E., Degenne, D., de Moerloose, P., Sanmarco, M., Potron, G., & On behalf of the working group on Methodologies in Haemostasis from the GEHT (Groupe d’Etudes sur I’Hémostase et la Thrombose), F.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1995
- Volume
- 73
- Issue
- 03
- Pages
- 444-452
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W4323283585
- Cited by
- 120
- References
- 0
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.