Potentially Clinically Important Inaccuracies in Testing for the Lupus Anticoagulant: an Analysis of Results from three Surveys of the UK National External Quality Assessment Scheme (NEQAS) for Blood Coagulation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Summary: The identification of the presence of antiphospholipid in plasma is recognised to be of diagnostic and prognostic importance in subjects with thrombotic disease, recurrent miscarriage or collagen vascular disorders. A number of coagulation assays are currently employed for the detection of lupus anticoagulant (LA), many of which are influenced by reagent dependent and methodological variables. In the present study lyophilised plasma samples from three subjects with “strong”, “weak” and “absent” LA were tested in 220 centres. The most commonly used tests for LA were Activated Partial Thromboplastin Time (APTT), Dilute Russell Viper Venom Time (DRVVT) and Kaolin Clotting Time (KCT). Median DRVVT ratios were 1.75, 1.17 and 1.10 for the three samples. The presence of a strong LA was not detected by 4% of laboratories. The correct diagnosis was made by 94% of users of DRVVT and 85% of users of KCT. A weak LA was not detected by over half of centres. Correction was observed on addition of plasma and also in platelet neutralisation. The correct diagnosis was made by 37% of users of DRVVT and 27% of users of KCT. Lupus Anticoagulant was falsely considered to be present in a Factor IX deficient plasma by approximately one quarter of laboratories. Amongst users of DRVVT and KCT absence of LA in this sample was correctly reported by 73% and 69% of centres respectively. The accuracy of testing for LA in the present study is suboptimal and this is likely to have important clinical consequences. There is clearly a need for greater conformity in the selection and performance of LA tests to facilitate accurate diagnosis of this important group of disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McNeil, H. P., Simpson, R. J., Chesterman, C. N., & Krilis, S. A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.11.4120 · Cited by 1,595
The management of thrombosis in the antiphospholipid-antibody syndrome
Khamashta, M. A., Cuadrado, M. J., Mujic, F., Taub, N. A., Hunt, B. J., & Hughes, G. R. V. (1995) · New England Journal of Medicine · doi:10.1056/nejm199504133321504 · Cited by 1,450
Brandt, J. T., Barna, L. K., & Triplett, D. A. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649988 · Cited by 228
Kelsey, P. R., Stevenson, K. J., & Poller, L. (1984) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1661166 · Cited by 91 · cited 1×
“tests is also well recognised: there is considerable variability in the sensitivity of the commonly used APTT reagents to LA (5, 7, 10, 11) this being largely determined by the phosphatidyl serine content (12).”
MethodEvaluation of Different Mixing Study Reagents and Dilution Effect in Lupus Anticoagulant Testing
Kaczor, D. A., Bickford, N. N., & Triplett, D. A. (1991) · American Journal of Clinical Pathology · doi:10.1093/ajcp/95.3.408 · Cited by 45 · cited 1×
“consideration applies to control plasmas used for mixing studies (16), as platelet contamination prior to freezing will lead to a quenching”
Background
Cited by
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197
Galli, M., Luciani, D., Bertolini, G., & Barbui, T. (2003) · Blood · doi:10.1182/blood-2002-02-0441 · Cited by 972
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Self-citationAntibody profiles for the diagnosis of antiphospholipid syndrome
Biasiolo, A., Pegoraro, C., Cucchini, U., Noventa, F., Iliceto, S., & Pengo, V. (2005) · Thrombosis and Haemostasis · doi:10.1160/th04-12-0839 · Cited by 320
The use of laboratory tests in the diagnosis of SLE
Egner, W. (2000) · Journal of Clinical Pathology · doi:10.1136/jcp.53.6.424 · Cited by 316
Metadata
- Authors
- Jennings, I., Kitchen, S., Woods, T. A. L., Preston, F. E., & Greaves, M.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1997
- Volume
- 77
- Issue
- 05
- Pages
- 0934-0937
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2411741803
- Cited by
- 103
- References
- 5
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.