Cited by 91Systemic Lupus Erythematosus ResearchBlood Coagulation and Thrombosis MechanismsHemophilia Treatment and Research

The Diagnosis of Lupus Anticoagulants by the Activated Partial Thromboplastin Time—the Central Role of Phosphatidyl Serine

Kelsey, P R, Stevenson, K J, Poller, L·1984·Thrombosis and Haemostasis

Abstract

Liposomes of pure phospholipids were used in a modified APTT test system and the role of phosphatidyl serine (PS) in determining the sensitivity of the test system to the presence of lupus anticoagulants was assessed. Six consecutive patients with lupus anticoagulants and seven haemophiliacs with anticoagulants directed at specific coagulation factors, were studied. Increasing the concentration of phospholipid in the test system markedly reduced the sensitivity to lupus anticoagulants but had marginal effect on the specific factor inhibitors. The same effect was achieved when the content of PS alone was increased in a vehicle liposome of constant composition. The results suggest that the lupus anticoagulants can best be detected by a screening method using an APTT test with a reagent of low PS content. The use of a reagent rich in PS will largely abolish the lupus anticoagulant's effect on the APTT. An approach using the two different types of reagent may facilitate differentiation of lupus inhibitors from other types of anticoagulant.

Integrity signals

Registry

Crossref · 10.1055/s-0038-1661166

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The higher the relative content of phosphatidylserine, the less the sensitivity of the assay to LA.

    “the higher the relative content of phosphatydilserine, the less the sensitivity of the assay to LA.”

    From Lupus Anticoagulant Detection under the Magnifying Glass (2023) · cites this paper as [44]

Cites

Still being checked.

Cited by

Sorted by citations

Authors
Kelsey, P. R., Stevenson, K. J., & Poller, L.
Affiliations
The U. K. Reference Laboratory for Anticoagulant Reagents and Control, Wlthlngton Hospital, Manchester, U. K.
Venue
Thrombosis and Haemostasis
Published
1984
Volume
52
Issue
02
Pages
172-175
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W6119856
Cited by
91
References
0
Citations by year
2023: 3 · 2022: 2 · 2020: 1 · 2016: 1 · 2014: 1 · 2012: 1
FWCI
4.52
Type
journal article
Language
en
Open access
closed
Locations
  • Thrombosis and Haemostasis (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Hematology › Hemophilia Treatment and Research
Keywords
lupus anticoagulant, activated partial thromboplastin time, phosphatidylserine, liposomes, coagulation factor inhibitors, hemophilia
MeSH terms
Adult, Aged, Blood Coagulation Factors, Blood Coagulation Tests, Female, Hemophilia A, Humans, Indicators and Reagents, Liposomes, Lupus Erythematosus, Systemic, Male, Mixed Connective Tissue Disease, Partial Thromboplastin Time, Phosphatidylserines, Lupus Coagulation Inhibitor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review