The DOI matches its Crossref record.
Effect of Plasma Dilution on Adsorption of Fibrinogen to Solid Surfaces
Abstract
Summary: The adsorption of various plasma proteins to three solid surfaces has been studied as a function of plasma concentration. Albumin adsorption on glass showed no dependence on plasma concentration and increased to a plateau value on both polyethylene and siliconized glass. Immunoglobulin G (IgG) adsorption showed no dependence on plasma concentration on any surface. Fibrinogen adsorption increased with plasma concentration and then decreased, the maximum occurring at about 1% normal plasma concentration and varying somewhat with the surface. On glass the kinetics of fibrinogen adsorption was dependent on plasma concentration: at concentrations less than the adsorption maximum, the kinetics was conventional, with adsorption increasing onto a plateau; at concentrations greater than the adsorption maximum, kinetics curves also showed maxima the position of which shifted to longer times as plasma concentration decreased. These data are interpreted in terms of competitive adsorption between fibrinogen and other, as yet unidentified species in plasma. The data reported are in general agreement with the model of Vroman (12) for plasma-surface interactions which holds that initially adsorbed fibrinogen is later replaced by high molecular weight kininogen (HMWK), the rate of replacement depending on the relative activity of the surface in promoting coagulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein adsorption in three dimensions
Vogler, E. A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.059 · Cited by 585
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
The Vroman effect: Competitive protein exchange with dynamic multilayer protein aggregates
Hirsh, S. L., McKenzie, D. R., Nosworthy, N. J., Denman, J. A., Sezerman, O. U., & Bilek, M. M. M. (2013) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2012.10.039 · Cited by 340
Human plasma fibrinogen adsorption and platelet adhesion to polystyrene
Tsai, W.-B., Grunkemeier, J. M., & Horbett, T. A. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<130::aid-jbm2>3.0.co;2-9 · Cited by 329
Feist, P., & Hummon, A. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023537 · Cited by 288
Metadata
- Authors
- Brash, J. L., & ten Hove, P.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1984
- Volume
- 51
- Issue
- 03
- Pages
- 326-330
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2432443528
- Cited by
- 193
- References
- 0
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Plasma Dilution on Adsorption of Fibrinogen to Solid Surfaces. https://app.cochat.ai/papers/10.1055/s-0038-1661093
- The paper
- Brash, J. L., & ten Hove, P. (1984). Effect of Plasma Dilution on Adsorption of Fibrinogen to Solid Surfaces. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1661093
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.