Impact of an automated system for endocytoscopic diagnosis of small colorectal lesions: an international web-based study
The DOI matches its Crossref record.
Abstract
Background and study aims: Optical diagnosis of colorectal polyps is expected to improve the cost-effectiveness of colonoscopy, but achieving a high accuracy is difficult for trainees. Computer-aided diagnosis (CAD) is therefore receiving attention as an attractive tool. This study aimed to validate the efficacy of the latest CAD model for endocytoscopy (380-fold ultra-magnifying endoscopy). Patients and methods: This international web-based trial was conducted between August and November 2015. A web-based test comprising one white-light and one endocytoscopic image of 205 small colorectal polyps (≤ 10 mm) from 123 patients was undertaken by both CAD and by endoscopists (three experts and ten non-experts from three countries). Outcome measures were accuracy in identifying neoplastic change in diminutive (≤ 5 mm) and small (≤ 10 mm) polyps, and accuracy in predicting post-polypectomy surveillance intervals according to current guidelines for high confidence optical diagnoses of diminutive polyps. Results: Of the 205 small polyps (147 neoplastic and 58 non-neoplastic), 139 were diminutive. CAD was accurate for 89 % (95 % confidence interval [CI] 83 % – 94 %) of diminutive polyps and 89 % (84 % – 93 %) of small polyps, which was significantly greater than results for the non-experts (73 % [71 % – 76 %], P < 0.001; and 76 % [74 % – 78 %], P < 0.001, respectively) and comparable with the experts’ results (90 % [87 % – 93 %], P = 0.703; and 91 % [89 % – 93 %], P = 0.106, respectively). The surveillance interval predicted by CAD provided 98 % (93 % – 100 %) and 96 % (91 % – 99 %) agreement with pathology-directed intervals of the European and American guidelines, respectively. Conclusions: The use of CAD in endocytoscopy can be effective in the management of diminutive/small colorectal polyps. UMIN Clinical Trial Registry: UMIN000018185.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mori, Y., Kudo, S.-E., Misawa, M., Saito, Y., Ikematsu, H., Hotta, K., Ohtsuka, K., Urushibara, F., Kataoka, S., Ogawa, Y., et al. (2018) · Annals of Internal Medicine · doi:10.7326/m18-0249 · Cited by 509
“Real-Time Working “Artificial Intelligence” System The algorithm of the CAD model (Figure 1) was developed on the basis of our previous study (8, 9).”
BackgroundMethodSelf-citationBarua, I., Vinsard, D. G., Jodal, H. C., Løberg, M., Kalager, M., Holme, Ø., Misawa, M., Bretthauer, M., & Mori, Y. (2021) · Endoscopy · doi:10.1055/a-1201-7165 · Cited by 271
Self-citationArtificial Intelligence in Colorectal Cancer Screening, Diagnosis and Treatment. A New Era
Mitsala, A., Tsalikidis, C., Pitiakoudis, M., Simopoulos, C., & Tsaroucha, A. K. (2021) · Current Oncology · doi:10.3390/curroncol28030149 · Cited by 271
Application of artificial intelligence in gastroenterology
Yang, Y. J., & Bang, C. S. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i14.1666 · Cited by 263
Maeda, Y., Kudo, S.-E., Mori, Y., Misawa, M., Ogata, N., Sasanuma, S., Wakamura, K., Oda, M., Mori, K., & Ohtsuka, K. (2019) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2018.09.024 · Cited by 245
Self-citationAhmad, O. F., Soares, A. S., Mazomenos, E., Brandao, P., Vega, R., Seward, E., Stoyanov, D., Chand, M., & Lovat, L. B. (2019) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(18)30282-6 · Cited by 215
Komeda, Y., Handa, H., Watanabe, T., Nomura, T., Kitahashi, M., Sakurai, T., Okamoto, A., Minami, T., Kono, M., Arizumi, T., et al. (2017) · Oncology · doi:10.1159/000481227 · Cited by 200
Artificial intelligence in gastroenterology: A state-of-the-art review
Kröner, P. T., Engels, M. M., Glicksberg, B. S., Johnson, K. W., Mzaik, O., van Hooft, J. E., Wallace, M. B., El-Serag, H. B., & Krittanawong, C. (2021) · World Journal of Gastroenterology · doi:10.3748/wjg.v27.i40.6794 · Cited by 165
Mori, Y., Kudo, S.-E., East, J. E., Rastogi, A., Bretthauer, M., Misawa, M., Sekiguchi, M., Matsuda, T., Saito, Y., Ikematsu, H., et al. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.03.3759 · Cited by 155
Self-citationArtificial intelligence and colonoscopy: Current status and future perspectives
Kudo, S., Mori, Y., Misawa, M., Takeda, K., Kudo, T., Itoh, H., Oda, M., & Mori, K. (2019) · Digestive Endoscopy · doi:10.1111/den.13340 · Cited by 147
Self-citationJin, E. H., Lee, D., Bae, J. H., Kang, H. Y., Kwak, M.-S., Seo, J. Y., Yang, J. I., Yang, S. Y., Lim, S. H., Yim, J. Y., et al. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.02.036 · Cited by 140
Tonozuka, R., Itoi, T., Nagata, N., Kojima, H., Sofuni, A., Tsuchiya, T., Ishii, K., Tanaka, R., Nagakawa, Y., & Mukai, S. (2021) · Journal of Hepato-Biliary-Pancreatic Sciences · doi:10.1002/jhbp.825 · Cited by 129
Diagnostic evaluation of a deep learning model for optical diagnosis of colorectal cancer
Zhou, D., Tian, F., Tian, X., Sun, L., Huang, X., Zhao, F., Zhou, N., Chen, Z., Zhang, Q., Yang, M., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16777-6 · Cited by 123
Real-Time Artificial Intelligence–Based Optical Diagnosis of Neoplastic Polyps during Colonoscopy
Barua, I., Wieszczy, P., Kudo, S.-E., Misawa, M., Holme, Ø., Gulati, S., Williams, S., Mori, K., Itoh, H., Takishima, K., et al. (2022) · NEJM Evidence · doi:10.1056/evidoa2200003 · Cited by 119
Self-citationArtificial intelligence in gastrointestinal endoscopy: general overview
El Hajjar, A., & Rey, J.-F. (2020) · Chinese Medical Journal · doi:10.1097/cm9.0000000000000623 · Cited by 102
“(2) CADx for polyp characterization and classification (also called optical biopsy or histology prediction).([11,12]) (3) CADx for mucosal inflammatory activity prediction in inflammatory bowel disease (IBD) patients.”
BackgroundArtificial intelligence and computer-aided diagnosis for colonoscopy: where do we stand now?
Kudo, S.-E., Mori, Y., Abdel-aal, U. M., Misawa, M., Itoh, H., Oda, M., & Mori, K. (2021) · Translational Gastroenterology and Hepatology · doi:10.21037/tgh.2019.12.14 · Cited by 21
“Various imaging technologies are considered as the targets for CAD for polyp characterization such as white-light endoscopy (12,13), magnifying narrow band imaging (NBI) (14,15), magnifying chromoendoscopy (16), endocytoscopy (17-20), confocal laser endomicroscopy (21) and laser-induced fluorescence spectroscopy (22-2…”
BackgroundSelf-citation
Metadata
- Authors
- Mori, Y., Kudo, S.-E., Chiu, P., Singh, R., Misawa, M., Wakamura, K., Kudo, T., Hayashi, T., Katagiri, A., Miyachi, H., Ishida, F., Maeda, Y., Inoue, H., Nimura, Y., Oda, M., & Mori, K.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2016-08-05
- Volume
- 48
- Issue
- 12
- Pages
- 1110-1118
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2500151826
- Cited by
- 112
- References
- 0
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.