A meta-analysis of endoscopic ultrasound–fine-needle aspiration compared to endoscopic ultrasound–fine-needle biopsy: diagnostic yield and the value of onsite cytopathological assessment
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background The diagnostic yield of endoscopic ultrasound (EUS) guided fine-needle aspiration (FNA) is variable, and partly dependent upon rapid onsite evaluation (ROSE) by a cytopathologist. Second generation fine-needle biopsy (FNB) needles are being increasingly used to obtain core histological tissue samples. Aims Studies comparing the diagnostic yield of EUS guided FNA versus FNB have reached conflicting conclusions. We therefore conducted a systematic review and meta-analysis to compare the diagnostic yield of FNA with FNB, and specifically evaluating the diagnostic value of ROSE while comparing the two types of needles. Methods We searched several databases from inception to 10 April 2016 to identify studies comparing diagnostic yield of second generation FNB needles with standard FNA needles. Risk ratios (RR) were calculated for categorical outcomes of interest (diagnostic adequacy, diagnostic accuracy, and optimal quality histological cores obtained). Standard mean difference (SMD) was calculated for continuous variables (number of passes required for diagnosis). These were pooled using random effects model of meta-analysis to account for heterogeneity. Meta-regression was conducted to evaluate the effect of ROSE on various outcomes of interest. Results Fifteen studies with a total of 1024 patients were included in the analysis. We found no significant difference in diagnostic adequacy [RR 0.98 (0.91, 1.06), (I 2 = 51 %)]. Although not statistically significant (P = 0.06), by meta-regression, in the absence of ROSE, FNB showed a relatively better diagnostic adequacy. For solid pancreatic lesions only, there was no difference in diagnostic adequacy [RR 0.96 (0.86, 1.09), (I 2 = 66 %)]. By meta-regression, in the absence of ROSE, FNB was associated with better diagnostic adequacy (P = 0.02). There was no difference in diagnostic accuracy [RR 0.99 (0.95, 1.03), (I 2 = 27 %)] or optimal quality core histological sample procurement [RR 0.97 (0.89, 1.05), (I 2 = 9.6 %)]. However, FNB established diagnosis with fewer passes [SMD 0.93 (0.45, 1.42), (I 2 = 84 %)]. The absence of ROSE was associated with a higher SMD, i. e., in the presence of an onsite pathologist, FNA required relatively fewer passes to establish the diagnosis than in the absence of an onsite pathologist. Conclusions There is no significant difference in the diagnostic yield between FNA and FNB, when FNA is accompanied by ROSE. However, in the absence of ROSE, FNB is associated with a relatively better diagnostic adequacy in solid pancreatic lesions. Also, FNB requires fewer passes to establish the diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 1×
“These outcome variables were pooled one at a time and a meta-analysis was performed using either a fixed effect model or Der-Simonian and Laird random effects model [17] depending on the presence or absence of significant heterogeneity, respectively, and corresponding forest plots constructed.”
MethodLiberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164 · cited 2×
“Methods This systematic review was carried out in accordance with the guidelines of the preferred reporting items for systematic reviews and meta-analyses (PRISMA) [13] and meta-analysis of observational studies in epidemiology (MOOSE) [14].”
MethodDermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,451
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00136 · Cited by 10,349
Chapter 9: Analysing Data and Undertaking Meta-Analyses
Deeks, J. J., Higgins, J. P. T., & Altman, D. G. (2008) · Cited by 2,782
Full publication of results initially presented in abstracts.
Scherer, R. W., Langenberg, P., & von Elm, E. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.mr000005.pub3 · Cited by 997 · cited 1×
“Data presented as abstracts were excluded, as there is a discrepancy between full publications and published abstracts [15, 16].”
BackgroundDumonceau, J., Polkowski, M., Larghi, A., Vilmann, P., Giovannini, M. F., Frossard, J., Heresbach, D., Pujol, B., Fernández‐Esparrach, G., Vázquez-Sequeiros, E., et al. (2011) · Endoscopy · doi:10.1055/s-0030-1256754 · Cited by 330 · cited 1×
“The reported diagnostic accuracy for other lesions such as mediastinal masses and gastrointestinal tract stromal tumors (GISTs) is even lower [7, 8].”
BackgroundBang, J. Y., Hebert-Magee, S., Trevino, J., Ramesh, J., & Varadarajulu, S. (2012) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2012.03.1392 · Cited by 269 · cited 1×
“Six studies [19, 21, 25, 28, 31, 32] had an onsite pathologist available for specimen analysis.”
BackgroundComparison of EUS-Guided 19-Gauge Trucut Needle Biopsy With EUS-Guided Fine-Needle Aspiration
Varadarajulu, S., Fraig, M., Schmulewitz, N., Roberts, S., Wildi, S. M., Hawes, R. H., Hoffman, B., & Wallace, M. B. (2004) · Endoscopy · doi:10.1055/s-2004-814316 · Cited by 250 · cited 1×
“Studies comparing the first generation Trucut biopsy needle with standard FNA failed to establish superiority of core biopsy needles to FNA [34,35].”
Bang, J., Hawes, R., & Varadarajulu, S. (2015) · Endoscopy · doi:10.1055/s-0034-1393354 · Cited by 233 · cited 1×
“A previous metaanalysis [36] of small numbers of studies and patient populations failed to show any difference between the diagnostic performances of FNA in comparison to second generation core biopsy needles; however, they did not specifically address the issue of onsite cytopathology, which is one of the major reaso…”
BackgroundTaddio, A., the CIHR Team in Children’s Pain, Fassos, F. F., Boon, H., Ilersich, A. L. T., & Einarson, T. R. (1994) · Europe PMC (PubMed Central) · Cited by 229
Mizuno, N., Bhatia, V., Hosoda, W., Sawaki, A., Hoki, N., Hara, K., Takagi, T. J., Ko, S. B. H., Yatabe, Y., Goto, H., et al. (2009) · Journal of Gastroenterology · doi:10.1007/s00535-009-0062-6 · Cited by 217 · cited 1×
“Major limitations of EUS-FNA are the relatively small amount of tissue obtained and the inability to provide core tissue for histochemical analysis, which is indispensable not only in the diagnosis of certain malignant conditions such as GISTs, and lymphoma but also in diagnosing benign conditions such as autoimmune p…”
BackgroundEUS-guided FNA for the diagnosis of GI stromal cell tumors: sensitivity and cytologic yield
Sepe, P. S., Moparty, B., Pitman, M. B., Saltzman, J. R., & Brugge, W. R. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.11.038 · Cited by 203 · cited 1×
“The reported diagnostic accuracy for other lesions such as mediastinal masses and gastrointestinal tract stromal tumors (GISTs) is even lower [7, 8].”
BackgroundEndoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin
Yasuda, I., Tsurumi, H., Omar, S., Iwashita, T., Kojima, Y., Yamada, T., Sawada, M., Takami, T., Moriwaki, H., & Soehendra, N. (2006) · Endoscopy · doi:10.1055/s-2006-944665 · Cited by 160
Lee, Y. K., Moon, J. H., Kim, H. J., Choi, H. S., Choi, M. H., Kim, D. W., Lee, T. H., Cha, S., Cho, Y., & Park, S. (2014) · Endoscopy · doi:10.1055/s-0034-1377558 · Cited by 149 · cited 4×
“Seven studies [20,23,25 – 28,33] used a cross-over design in which both needles were used in all patients, while eight studies [19,21,22,24,29 – 32] used either a standard FNA needle or a core biopsy needle in each patient.”
BackgroundMethodResultInfluentialKim, G. H., Cho, Y. K., Kim, E. Y., Kim, H. K., Cho, J. W., Lee, T. H., Moon, J. S., & The Korean Eus Study Group (2013) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365521.2013.867361 · Cited by 137 · cited 1×
“Seven studies [19, 23–25,28–30] included pancreatic lesions exclusively while one study [22] included subepithelial lesions exclusively.”
BackgroundFeasibility and efficiency of a new 22G core needle: a prospective comparison study
Hucl, T., Wee, E., Sekaran, A., Gupta, R., Ramchandani, M. J., Kalpala, R., Shrestha, R., Reddy, D. N., & Lakhtakia, S. (2013) · Endoscopy · doi:10.1055/s-0033-1344217 · Cited by 107 · cited 1×
“Three studies [20, 29, 32] satisfied the criteria of high quality studies, seven [21, 26–28, 30, 31, 33] were of moderate quality, and one [25] was of low quality (▶Table 2).”
ResultStorch, I. M., Jordà, M., Thurer, R., Raez, L. E., Rocha-Lima, C. S., Vernon, S. E., & Ribeiro, A. C. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.02.056 · Cited by 94 · cited 1×
“Studies comparing the first generation Trucut biopsy needle with standard FNA failed to establish superiority of core biopsy needles to FNA [34, 35].”
Strand, D. S., Jeffus, S. K., Sauer, B. G., Wang, A. Y., Stelow, E. B., & Shami, V. M. (2014) · Diagnostic Cytopathology · doi:10.1002/dc.23116 · Cited by 85 · cited 6×
“[25] as it appeared to be an outlier in the estimate.”
BackgroundMethodResultInfluentialCURRENT STATUS OF DIAGNOSTIC ENDOSCOPIC ULTRASONOGRAPHY IN THE EVALUATION OF PANCREATIC MASS LESIONS
Itoi, T., Sofuni, A., Itokawa, F., Irisawa, A., Khor, C. J. L., & Rerknimitr, R. (2011) · Digestive Endoscopy · doi:10.1111/j.1443-1661.2011.01132.x · Cited by 80 · cited 1×
“Despite its widespread adoption, the diagnostic yield of FNA is highly variable, as is evident with solid pancreatic neoplasms, where reported sensitivities range from 64% to 95 %, specificities range from 75% to 100%, and diagnostic accuracies range from 78% to 95% [6].”
BackgroundRodrigues‐Pinto, E., Jalaj, S., Grimm, I. S., & Baron, T. H. (2016) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2016.06.034 · Cited by 75
Self-citationEndoscopic ultrasound-guided fine-needle aspiration of left adrenal gland masses
DeWitt, J. M., Alsatie, M., LeBlanc, J. K., McHenry, L., & Sherman, S. (2007) · Endoscopy · doi:10.1055/s-2006-945042 · Cited by 73 · cited 1×
“Endoscopic ultrasound (EUS) guided fine-needle aspiration (EUS-FNA) is the mainstay for tissue acquisition for evaluation of lesions adjacent to the digestive tract, including pancreas, liver, adrenals, lymph nodes, and gastrointestinal subepithelial tumors [1 – 5].”
BackgroundMavrogenis, G., Weynand, B., Sibille, A., Hassaini, H., Deprez, P. H., Gillain, C., & Warzée, P. (2014) · Endoscopy International Open · doi:10.1055/s-0034-1390889 · Cited by 44
Dwyer, J. B., Pantanowitz, L., Ohori, N. P., Pai, R. K., Vrbin, C. M., Brand, R. E., & Monaco, S. E. (2015) · Cancer Cytopathology · doi:10.1002/cncy.21623 · Cited by 34 · cited 1×
“Six studies [19, 21, 25, 28, 31, 32] had an onsite pathologist available for specimen analysis.”
BackgroundWhen Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?
Schmidt, R. L., Walker, B. S., & Cohen, M. B. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135466 · Cited by 31 · cited 8×
“The following MeSH, Emtree, and keyword search terms were used: “ endoscopic ultrasound ” , “ EUS ” , “ fine needle aspiration ” , “ fine needle biopsy ” , “ Pro-Core ” , “ core biopsy ” , “ fork-tip needle ” , “ SharkCore ” , “ EUS-FNA ” , and “ EUS-FNB ” .”
BackgroundInfluentialLin, M. F., Hair, C. D., Green, L., et al. (2014) · Endoscopy International Open · doi:10.1055/s-0034-1377611 · Cited by 21 · cited 1×
“[26] found that FNB using two needle passes had similar diagnostic accuracy as FNA.”
Method
Cited by
European Guideline on IgG4-related digestive disease - UEG and SGF evidence-based recommendations
Löhr, J., Beuers, U., Vujasinovic, M., Alvaro, D., Frøkjær, J. B., Buttgereit, F., Capurso, G., Culver, E. L., de‐Madaria, E., Della‐Torre, E., et al. (2020) · United European Gastroenterology Journal · doi:10.1177/2050640620934911 · Cited by 252
Metadata
- Authors
- Khan, M., Grimm, I., Ali, B., Nollan, R., Tombazzi, C., Ismail, M., & Baron, T.
- Venue
- Endoscopy International Open
- Publisher
- Georg Thieme Verlag KG
- Published
- 2017-05
- Volume
- 05
- Issue
- 05
- Pages
- E363-E375
- ISSN
- 2196-9736 (ISSN-L)
- 2364-3722
- OpenAlex
- W2613912677
- Cited by
- 188
- References
- 28
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.