Assay Methods for the Measurement of Total Homocyst(e)ine in Plasma
The DOI matches its Crossref record.
Abstract
Analytical methods to measure plasma total homocyst(e)ine (tHcy) concentrations are reviewed. High-pressure liquid chromatography (HPLC) with fluorometric detection is the most widely used method to determine plasma tHcy concentrations. Both monobromobimane and ammonium 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-F) are popular thiol-specific fluorogenic agents suitable for tHcy analysis. Monobromobimane has the advantage that it is highly reactive towards thiols, but its hydrolysis products are also fluorogenic, thus necessitating complex chromatography to obtain satisfactory separation between the compounds of interest and interferents. SBD-F does not show fluorescence, thus allowing isocratic separation of SBD-F derivatized thiols. SBD-thiol adducts are light sensitive and require protection against light to ensure reliable results. HPLC with electrochemical detection is also often used and has the advantage that no derivatization of thiols is required prior to detection. A recently reported liquid chromatography electrospray tandem mass spectrometric assay has the potential to become the reference method for plasma tHcy analysis. Other methods to measure plasma tHcy concentrations include gas-liquid chromatography, capillary electrophoresis, and immunoassays. Fluorescence polarization immunoassay compares well with gas chromatography-mass spectrometry and may become the method of choice in routine diagnostic clinical chemistry laboratories. Instability of tHcy in whole blood as well as postprandial and orthostatic variation are preanalytical factors that should be accounted for in plasma tHcy analysis. Between-method and between-laboratory variations in serum tHcy analysis are not yet satisfactory; certified reference material and standardization of the plasma tHcy assay will be essential to reduce between-laboratory bias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Facts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
“The different tHcy methods give comparable results (16, 27), but the variations among methods and among laboratories are considerable (16, 28–31).”
MethodResultDetection of Homocysteine and Cysteine
Wang, W., Rusin, O., Xu, X., Kim, K. K., Escobedo, J. O., Fakayode, S. O., Fletcher, K. A., Lowry, M., Schowalter, C. M., Lawrence, C. M., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054962n · Cited by 593
Carmina, E., Chu, M. C., Longo, R. A., Rini, G. B., & Lobo, R. A. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-2279 · Cited by 274
Recent advances in amino acid analysis by capillary electrophoresis
Prata, C., Bonnafous, P., Fraysse, N., Treilhou, M., Poinsot, V., & Couderc, F. (2001) · ELECTROPHORESIS · doi:10.1002/1522-2683(200111)22:19<4129::aid-elps4129>3.0.co;2-i · Cited by 172
Amarnath, K. (2003) · Talanta · doi:10.1016/s0039-9140(03)00232-7 · Cited by 164
Metadata
- Authors
- UBBINK, J. B.
- Venue
- Seminars in Thrombosis and Hemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2000
- Volume
- Volume 26
- Issue
- Number 03
- Pages
- 233-242
- ISSN
- 0094-6176 (ISSN-L)
- 1098-9064
- OpenAlex
- W2084817109
- Cited by
- 72
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assay Methods for the Measurement of Total Homocyst(e)ine in Plasma. https://app.cochat.ai/papers/10.1055/s-2000-8468
- The paper
- UBBINK, J. B. (2000). Assay Methods for the Measurement of Total Homocyst(e)ine in Plasma. Seminars in Thrombosis and Hemostasis. https://doi.org/10.1055/s-2000-8468
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.