CoChat

Reliability of Gas Exchange Measurements from Two Different Spiroergometry Systems

Meyer, T., Georg, T., Becker, C., Kindermann, W. · 2001 · International Journal of Sports Medicine
Cited by 131

The DOI matches its Crossref record.

Abstract

Reliability of two different spiroergometric systems was investigated by comparing gas exchange measurements from two consecutive identical bicycle ergometer ramp exercise tests which were conducted after an initial habituation trial. Twenty-three healthy subjects (age: 25+/-5 years; weight: 71+/-10 kg; peak oxygen uptake: 55+/-9 ml x min(-1) x kg(-1)) took part in the study. One apparatus was a portable mixing chamber system (MetaMax I, Cortex, Leipzig, Germany), the other one a stationary spiroergometric device measuring in the breath-by-breath mode (MetaLyzer 3B, Cortex). There were no relevant systematic changes in gas exchange measurements and heart rate from test 1 to test 2. Intra-class reliability coefficients were 0.984 (oxygen uptake = VO2), 0.977 (carbon dioxide output = VCO2), and 0.973 (minute ventilation = VE) for the MetaMax I, and 0.969 (VO2), 0.964 (VCO2), and 0.953 (VE) for the MetaLyzer 3B. Bland-Altman plots revealed a slightly smaller variability of MetaLyzer 3B measurements compared to those of MetaMax I. It is concluded that the spiroergometric devices MetaMax I and MetaLyzer 3B represent reliable instruments for exercise testing in sports medical routine and research. This is important to decide if longitudinal changes in gas exchange measurements represent clinically meaningful differences in performance or merely inconsistencies of the measuring tool.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2001-18523

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 131

Metadata

Authors
Meyer, T., Georg, T., Becker, C., & Kindermann, W.
Venue
International Journal of Sports Medicine
Published
2001-11
Volume
22
Issue
8
Pages
593-597
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W2051788410
Cited by
131
References
0
FWCI
3.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of Gas Exchange Measurements from Two Different Spiroergometry Systems. https://app.cochat.ai/papers/10.1055/s-2001-18523
The paper
Meyer, T., Georg, T., Becker, C., & Kindermann, W. (2001). Reliability of Gas Exchange Measurements from Two Different Spiroergometry Systems. International Journal of Sports Medicine. https://doi.org/10.1055/s-2001-18523

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.