New Liver Support Devices in Acute Liver Failure: A Critical Evaluation
The DOI matches its Crossref record.
Abstract
Acute liver failure remains a condition with substantial mortality in spite of the best available medical care. Liver transplantation is often not possible or delayed, and liver support systems can be used to maintain the patient during the crisis by bridging to transplantation or allowing recovery of the native liver. Bioartificial devices, using porcine or human hepatocytes, have yielded encouraging results on consciousness levels in a number of studies and have generally been found to be safe, although in one large controlled trial reported to date, benefit was restricted to certain subgroups. Artificial devices, like those based on albumin dialysis, are undoubtedly effective in removing protein-bound toxins, and uncontrolled evidence shows some survival benefit. The large multicenter controlled trials necessary for proving the value of these systems are difficult to design. They have to take into account the influence of transplantation, etiology, and other factors on outcome. Achieving a standard medical regime for these critically ill patients between different centers is also difficult.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bernal, W., Hall, C., Karvellas, C. J., Auzinger, G., Sizer, E., & Wendon, J. (2007) · Hepatology · doi:10.1002/hep.21838 · Cited by 480
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Acute Liver Failure Including Acetaminophen Overdose
Fontana, R. J. (2008) · Medical Clinics of North America · doi:10.1016/j.mcna.2008.03.005 · Cited by 249
In vitro analysis of a hepatic device with intrinsic microvascular-based channels
Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., et al. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9194-3 · Cited by 168
Arkadopoulos, N., Vlahakos, D., Kostopanagiotou, G., Panagopoulos, D., Karvouni, E., Routsi, C., Kalimeris, K., Andreadou, I., Kouskouni, E., & Smyrniotis, V. (2008) · Liver Transplantation · doi:10.1002/lt.21505 · Cited by 13
Metadata
- Venue
- Seminars in Liver Disease
- Publisher
- Georg Thieme Verlag KG
- Published
- 2003
- Volume
- 23
- Issue
- 3
- Pages
- 283-294
- ISSN
- 0272-8087 (ISSN-L)
- 1098-8971
- OpenAlex
- W46820382
- Cited by
- 60
- References
- 0
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Liver Support Devices in Acute Liver Failure: A Critical Evaluation. https://app.cochat.ai/papers/10.1055/s-2003-42646
- The paper
- New Liver Support Devices in Acute Liver Failure: A Critical Evaluation. (2003). Seminars in Liver Disease. https://doi.org/10.1055/s-2003-42646
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.