Validity and Stability of a Computerized Metabolic System with Mixing Chamber
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The aim of this study was to validate a computerized metabolic system with mixing chamber (Oxycon Pro, Erich Jaeger GmbH, Hoechberg, Germany) against the Douglas bag method (1) over a large range of ventilations and (2) for drift during shorter (25-min time trial) and longer (approximately three months) test periods. Eighteen well-trained/elite cyclists performed graded exercise tests, maximal oxygen uptake tests and time trial tests on an electromagnetic braked cycle ergometer. Respiratory variables were measured simultaneously, once or several times in every test by the Oxycon Pro and the Douglas bag method. (1) Overall, oxygen uptake was 0.8 % (0.03 l x min(-1)) lower with the Oxycon Pro than with the Douglas bag method with a coefficient of variation of 1.2 % (n = 802) (p < 0.05). (2) During the time trials, oxygen uptake measured with the Oxycon Pro gradually decreased from 0.5 % (0.02 l) lower than the Douglas bag method at 5 min to 1.0 % (0.05 l) lower at 25 min (p < 0.05). Over the period of three months of testing, oxygen uptake measured with the Oxycon Pro gradually increased from 1.1 % (0.04 l) lower than the Douglas bag method at the start to 0.5 % (0.02 l) lower at the end (p < 0.05). This study demonstrates that a computerized metabolic system with mixing chamber is an accurate system for measuring oxygen uptake. This applies to testing over a large range of ventilations and for stability both during shorter and longer test periods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Oxidation of combined ingestion of glucose and fructose during exercise
Jentjens, R. L. P. G., Moseley, L., Waring, R. H., Harding, L. K., & Jeukendrup, A. E. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00974.2003 · Cited by 310
Cited by
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Myers, J., Arena, R., Franklin, B., Pina, I., Kraus, W. E., McInnis, K., & Balady, G. J. (2009) · Circulation · doi:10.1161/circulationaha.109.192520 · Cited by 338
The Role and Development of Sprinting Speed in Soccer
Haugen, T. A., Tønnessen, E., Hisdal, J., & Seiler, S. (2014) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2013-0121 · Cited by 334
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system
Macfarlane, D. J., & Wong, P. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2230-7 · Cited by 167
“The Oxycon Pro system acted as a ‘‘secondary criterion’’ as it has been shown to be a valid metabolic system in its mixing-chamber mode (Foss and Hallen 2005).”
BackgroundResultHirschberg, A. L., Elings Knutsson, J., Helge, T., Godhe, M., Ekblom, M., Bermon, S., & Ekblom, B. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2018-100525 · Cited by 106
Energy system contribution during competitive cross-country skiing
Losnegard, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04158-x · Cited by 99
Beltrami, F. G., Froyd, C., Mamen, A., & Noakes, T. D. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2825-x · Cited by 5
Metadata
- Authors
- Foss, Ø., & Hallén, J.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2005-09
- Volume
- 26
- Issue
- 7
- Pages
- 569-575
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2071016114
- Cited by
- 127
- References
- 2
- FWCI
- 5.17
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.