Respiratory Muscle Deoxygenation and Ventilatory Threshold Assessments Using Near Infrared Spectroscopy in Children
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The aim of this study was to assess respiratory muscles deoxygenation and to determine ventilatory threshold using near infrared spectroscopy (NIRS) in children during incremental cardiopulmonary exercise. Fourteen healthy children with a mean +/- SD age of 12.8 +/- 1.4 yrs performed an incremental exercise test on a cycle ergometer. NIRS was used to assess deoxygenation of the respiratory muscles. Ventilatory parameters (oxygen uptake, carbon dioxide production, and ventilation minute), power output, and tissue saturation (StO2) were measured. Ventilatory threshold was determined by the two following methods: the V-slope method which corresponds to the breakpoint in VCO2 as a function VO2 relationship (VT(V-slope)) and the NIRS method which corresponds to the point of rapid fall in StO2 (VT(nirs)). During exercise, the respiratory muscles deoxygenated as the exercise intensity increased. StO2 decrease progressively until an abrupt decrease was observed. No significant differences were observed between cardiorespiratory variables corresponding either to VT(V-slope) or to VT(nirs). The two methods showed a good agreement (data were inside the 95 % confidence interval). Likewise, a significant relationship was found between VT(V-slope) and VT(nirs) for each parameter measured (r = 0.87 to 0.94, p < 0.001). We concluded that respiratory muscles deoxygenate during incremental exercise in children and that ventilatory threshold could be determined by NIRS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Belardinelli, R., Barstow, T. J., Porszasz, J., & Wasserman, K. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00634377 · Cited by 213
Detection of ventilatory threshold using near infrared spectroscopy in men and women
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00017 · Cited by 89
Differentiated ratings of perceived exertion at ventilatory threshold in children and adults
Mahon, A. D., Gay, J. A., & Stolen, K. Q. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050395 · Cited by 67
Reliability of the rating of perceived exertion at ventilatory threshold in children
Mahon, A., & Marsh, M. (1992) · International Journal of Sports Medicine · doi:10.1055/s-2007-1024566 · Cited by 46
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Boone, J., Vandekerckhove, K., Coomans, I., Prieur, F., & Bourgois, J. G. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3468-x · Cited by 68
“The response of respiratory muscle oxygenation was first studied in heart failure patients (Mancini et al. 1991; Terakado et al. 1999) and children (Moalla et al. 2005).”
BackgroundInfluentialDetermination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182828ab2 · Cited by 65
Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise
Contreras-Briceño, F., Espinosa-Ramirez, M., Hevia, G., Llambias, D., Carrasco, M., Cerda, F., López-Fuenzalida, A., García, P., Gabrielli, L., & Viscor, G. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1653422 · Cited by 40
(2012) · Europe PMC (PubMed Central) · Cited by 23
Metadata
- Authors
- Moalla, W., Dupont, G., Berthoin, S., & Ahmaidi, S.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2005-09
- Volume
- 26
- Issue
- 7
- Pages
- 576-582
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2057660538
- Cited by
- 30
- References
- 7
- FWCI
- 2.22
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.