CoChat

Validation of a New Portable Ergospirometric Device (Oxycon Mobile®) During Exercise

Perret, C., Mueller, G. · 2006 · International Journal of Sports Medicine
Cited by 71

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to test the accuracy of a new portable spirometric-telemetric device (Oxycon Mobile) over a wide range of exercise intensities against an accurate stationary apparatus (Oxycon Pro). Therefore, fifteen endurance-trained subjects (VO2peak: 58.8 +/- 5.2 ml x min(-1) x kg(-1)) performed an incremental as well as an endurance exercise test on two different occasions. Gas exchange variables were measured by the two ergospirometric devices simultaneously. For this purpose, a special face mask was designed which allowed respiratory gas sampling with both devices at exactly the same time. Compared to the Oxycon Pro as an accurate reference system, the Oxycon Mobile showed significantly lower values for VO2 at 200 and 250 W during the incremental exercise test. For VCO2 no significant differences were found although the Oxycon Mobile seemed to systematically measure higher values. With regard to RER the Oxycon Mobile showed significantly higher values at all workloads tested. We therefore dissuade from comparing gas exchange variables collected by the Oxycon Mobile with data measured under laboratory conditions by an accurate reference system like the Oxycon Pro. Furthermore, the extrapolation of information about substrate utilization during different exercise durations and intensities from data measured by the Oxycon Mobile seems inappropriate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2005-865666

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 71

Metadata

Authors
Perret, C., & Mueller, G.
Venue
International Journal of Sports Medicine
Published
2006-05
Volume
27
Issue
5
Pages
363-367
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W2084508099
Cited by
71
References
1
FWCI
9.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a New Portable Ergospirometric Device (Oxycon Mobile®) During Exercise. https://app.cochat.ai/papers/10.1055/s-2005-865666
The paper
Perret, C., & Mueller, G. (2006). Validation of a New Portable Ergospirometric Device (Oxycon Mobile®) During Exercise. International Journal of Sports Medicine. https://doi.org/10.1055/s-2005-865666

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.