Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 289

The DOI matches its Crossref record.

A Pooled Analysis to Evaluate Results of Capsule Endoscopy Trials

Lewis, B. S., Eisen, G. M., Friedman, S.·2005·Endoscopy

Abstract

BACKGROUND AND STUDY AIM: Capsule endoscopy is a new tool in the evaluation of the small intestine. To speed evaluation and acceptance of this technology, the manufacturer (Given Imaging Ltd, Yoqneam, Israel) funded several trials. The data from these trials were collected at a central repository using a standardized reporting tool. Presentation of this data to the US Food and Drug Administration (FDA) in July 2003 led to the removal of the adjunctive term with regard to indication for capsule endoscopy, recognizing that the method is of independent importance for evaluating the small bowel. The aim of the present study was to combine the data from several capsule trials to help determine the yield and miss rate of capsule endoscopy for different diseases, compared with alternative diagnostic modalities. METHODS: Capsule studies were identified from a master database of funded studies. Studies were included in the pooled analysis if they reported a prospective comparison with another modality for evaluation of the small intestine. RESULTS: 32 studies with a total of 691 patients were found in the master database, of which 24 studies, representing 530 patients, met inclusion criteria and were entered into the pooled analysis. Prior to study entry, patients had undergone a mean of 6.77 diagnostic procedures, without findings. Of these 24 studies, 14 (involving 310 patients) were categorized as "bleeding" studies, and 10 studies (220 patients) as "nonbleeding small-bowel disorders" studies. The comparison procedure was push enteroscopy in 300 patients (in 45 for nonbleeding disorders), small-bowel series in 140 patients (in 125 for non-bleeding disorders), and colonoscopy with ileoscopy in 90 patients (50 for nonbleeding disorders). Overall analysis per patient showed new findings from capsule endoscopy in 50 % of patients; 17 % had new findings from the comparison method; in 22 % there were similar findings; and in 11 % there were no findings. A total of 1349 instances of disease were identified in the 530 examinations. Capsule endoscopy solely detected 87 % of the disease instances, while the comparison method solely detected 13 %. The yield for push enteroscopy alone was 14.8 %, for small-bowel series it was 9.9 %, and for colonoscopy it was 13.2 %. Capsule endoscopy missed 146 disease instances for a miss rate of 10 %; 989 were missed by the comparison methods for a miss rate of 73 %; and 214 were detected by both methods. CONCLUSION: Capsule endoscopy is the state of the art method for noninvasive detection of small-bowel disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2005-870353

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 289

Metadata

Authors
Lewis, B. S., Eisen, G. M., & Friedman, S.
Venue
Endoscopy
Published
2005-10
Volume
37
Issue
10
Pages
960-965
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2033293942
Cited by
289
References
0
FWCI
10.80
Type
journal article
Language
de
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Pooled Analysis to Evaluate Results of Capsule Endoscopy Trials. https://app.cochat.ai/papers/10.1055/s-2005-870353
The paper
Lewis, B. S., Eisen, G. M., & Friedman, S. (2005). A Pooled Analysis to Evaluate Results of Capsule Endoscopy Trials. Endoscopy. https://doi.org/10.1055/s-2005-870353

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.