Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24,500 patients from 191 centers in Germany and Austria

Schütt, M., Kern,, W., Krause, U., Busch,, P., Dapp, A., Grziwotz,, R., Mayer, I., Rosenbauer,, J., Wagner, C., Zimmermann,, A., Kerner, W., Holl, R. · 2006 · Experimental and Clinical Endocrinology & Diabetes

The DOI matches its Crossref record.

Abstract

Blood glucose measurements are generally accepted components of a modern diabetes self-management. The value of self-monitoring of blood glucose (SMBG) is, however, discussed controversially and only a few studies addressed the efficacy of SMBG under real-life conditions so far. In order to investigate whether the frequency of SMBG is related to long-term metabolic control, data from the DPV-Wiss-database, a standardized,prospective, computer-based documentation of diabetes care and outcome, were analyzed for patients with type 1(n = 19,491) and type 2 (n = 5,009) diabetes from 191 centers in Germany and Austria. Local HbA1c reference ranges were mathematically adjusted to the DCCT reference. For each patient, data from the most recent year of diabetes care were used. On average,patients with type 1 diabetes performed 4.4 blood glucose measurements/day. Corrected for age, gender, diabetes duration,on intensified (>or=4 daily injections or CSII) therapy (HbA1c reduction of 0.32% for one additional SMBG/day) compared to patients on conventional (1-3 daily injections) therapy(HbA1c-reduction of 0.16% for one additional SMBG/day). In 2,021 patients with insulin-treated type 2 diabetes (2.7 measurements/day), more frequent SMBG was associated with better metabolic control (HbA1c-reduction of 0.16% for one additionalSMBG/day, p < 0.0001), while in 2,988 patients on OAD or diet alone (2.0 measurements/day), more frequent blood glucose measurements were associated with higher HbA1c-levels(HbA1c-increase of 0.14% for one additional SMBG/day,p < 0.0001). These data indicate that more frequent SMBG are associated with better metabolic control in both, patients with type 1 and insulin-treated type 2 diabetes. Since no benefit ofSMBG on metabolic control was found in patients with type 2 diabetes on OAD or diet alone, SMBG should primarily be recommended for those patients with suboptimal metabolic control whereas the benefit of SHBG in non-insulin-treated patients with adequate HbA1c-levels remains uncertain.insulin therapy and center difference, the SMBG frequency was associated with better metabolic control (HbA1c-reduction of0.26% for one additional SMBG/day, p < 0.0001). HbA1c-reduction with higher frequency of SMBG was more pronounced in patients Blood glucose measurements are generally accepted components of a modern diabetes self-management. The value of self-monitoring of blood glucose (SMBG) is, however, discussed controversially and only a few studies addressed the efficacy of SMBG under real-life conditions so far. In order to investigate whether the frequency of SMBG is related to long-term metabolic control, data from the DPV-Wiss-database, a standardized,prospective, computer-based documentation of diabetes care and outcome, were analyzed for patients with type 1(n = 19,491) and type 2 (n = 5,009) diabetes from 191 centers in Germany and Austria. Local HbA1c reference ranges were mathematically adjusted to the DCCT reference. For each patient, data from the most recent year of diabetes care were used. On average,patients with type 1 diabetes performed 4.4 blood glucose measurements/day. Corrected for age, gender, diabetes duration,insulin therapy and center difference, the SMBG frequency wasassociated with better metabolic control (HbA1c-reduction of 0.26% for one additional SMBG/day, p < 0.0001). HbA1c-reduction with higher frequency of SMBG was more pronounced in patients on intensified (>or= 4 daily injections or CSII) therapy (HbA1c reduction of 0.32% for one additional SMBG/day) compared to patients on conventional (1-3 daily injections) therapy(HbA1c-reduction of 0.16% for one additional SMBG/day). In 2,021 patients with insulin-treated type 2 diabetes (2.7 measurements/day), more frequent SMBG was associated with better metabolic control (HbA1c-reduction of 0.16% for one additionalSMBG/day, p < 0.0001), while in 2,988 patients on OAD or diet alone (2.0 measurements/day), more frequent blood glucose measurements were associated with higher HbA1c-levels(HbA1c-increase of 0.14% for one additional SMBG/day, p < 0.0001). These data indicate that more frequent SMBG are associated with better metabolic control in both, patients with type 1 and insulin-treated type 2 diabetes. Since no benefit of SMBG on metabolic control was found in patients with type 2 diabetes on OAD or diet alone, SMBG should primarily be recommended for those patients with suboptimal metabolic control whereas the benefit of SHBG in non-insulin-treated patients with adequate HbA1c-levels remains uncertain.

Overview

Integrity signals

Registry

Crossref · 10.1055/s-2006-924152

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 237

Metadata

Authors
Schütt, M., Kern, Krause, U., Busch, Dapp, A., Grziwotz, Mayer, I., Rosenbauer, Wagner, C., Zimmermann, Kerner, W., & Holl, R.
Affiliations
  • University of Lübeck (DE)
  • Universität Ulm (DE)
  • SLK-Kliniken Heilbronn (DE)
  • Kreiskrankenhaus Gummersbach (DE)
  • Deutsches Diabetes-Zentrum e.V. (DE)
  • Institute for Diabetes Gerhardt Katsch (DE)
Venue
Experimental and Clinical Endocrinology & Diabetes
Published
2006-08-16
Volume
114
Issue
07
Pages
384-388
ISSN
  • 0947-7349 (ISSN-L)
  • 1439-3646
OpenAlex
W1981356692
Cited by
218
References
0
Citations by year
2026: 1 · 2025: 4 · 2024: 8 · 2023: 7 · 2022: 8 · 2021: 3 · 2020: 8 · 2019: 12 · 2018: 20 · 2017: 15 · 2016: 10 · 2015: 19 · 2014: 14 · 2013: 10 · 2012: 13
FWCI
8.38
Type
journal article
Language
en
Open access
closed
Locations
  • Experimental and Clinical Endocrinology & Diabetes (publishedVersion)
  • PubMed (publishedVersion)
Funders
Bundesministerium für Gesundheit
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
self-monitoring of blood glucose, HbA1c, glycemic control, type 1 diabetes, type 2 diabetes, intensive insulin therapy, insulin pump therapy, oral antidiabetic drugs, diabetes self-management, real-world data
MeSH terms
Austria, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Germany, Homeostasis, Humans, Patient Compliance, Self Care, Blood Glucose Self-Monitoring, Databases, Factual

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24,500 patients from 191 centers in Germany and Austria. https://app.cochat.ai/papers/10.1055/s-2006-924152
The paper
Schütt, M., Kern, Krause, U., Busch, Dapp, A., Grziwotz, Mayer, I., Rosenbauer, Wagner, C., Zimmermann, Kerner, W., & Holl, R. (2006). Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24,500 patients from 191 centers in Germany and Austria. Experimental and Clinical Endocrinology & Diabetes. https://doi.org/10.1055/s-2006-924152

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.