CoChat

On the Evolution of Some Endoscopic Light Delivery Systems for Photodynamic Therapy

Open access
van den Bergh, H. · 1998 · Endoscopy
Cited by 73

The DOI matches its Crossref record.

Abstract

Progress in photodynamic therapy (PDT) depends on the development of: (1) photosensitizers, (2) optical devices among which are lasers and light delivery systems, and (3) clinical procedure. The light delivery systems which are the focus of this article are fiberoptic devices developed in Lausanne, Switzerland for use in the endoscopic treatment of cancer or precancerous lesions in the bronchi, the esophagus, the uterus, the cervix, the upper aerodigestive tract and thoracic cavity. Light delivery systems for both surface and interstitial application are presented, together with some of the physical principles on which they are based. Incorporation in these devices of the possibility for in-situ measurement of reflected therapeutic light and/or fluorescence emitted by endogenous and/or exogenous dyes allows for improved light and drug dosimetry, as well as the measurement of photobleaching, local oxygenation and other tissue properties. The necessity of information on tissue optical parameters, as well as the use of simple mathematical models and tissue phantoms, for optimizing light distributing devices is underlined. The devices are optimized for delivering the desired light intensity distribution to the targeted region with minimal losses. In some cases this implies using the device to modify the shape of the hollow organ during PDT, an example of which is given for the case of the esophagus. In another strategy, one adapts the shape of the device to that of the organ, using an elastic balloon catheter. Here examples are given for the uterus, the bronchi and the thoracic cavity. The mechanical properties, the sizes, shapes and materials of the light delivery systems must be optimized for safe use while retaining low cost. Furthermore, the devices must whenever possible be rendered compatible with existing medical technology. A significant improvement in clinical efficacy has been demonstrated in the testing of some of these new fiberoptic light delivery systems. For endoscopic PDT in the hollow organs, the design and optimalization of multiple new approaches to light distribution will continue to lead to improved clinical results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2007-1001289

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
van den Bergh, H.
Venue
Endoscopy
Published
1998-05
Volume
30
Issue
04
Pages
392-407
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2119388219
Cited by
73
References
0
FWCI
6.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.