Validity and Reliability of the Cosmed K2 Instrument
The DOI matches its Crossref record.
Abstract
The purpose of this study was to measure the validity and reliability of a portable telemetry system (Cosmed K2) for measurement of oxygen consumption (VO2) during a laboratory exercise test at submaximum and maximum intensities. Twenty subjects performed three testing sessions on a treadmill on three consecutive days. Each testing session consisted of a submaximal and a maximal exercise test. On one day, VO2 was determined with the conventional Douglas bag method, and on the other two days, VO2 was determined using the Cosmed K2 system. Utilization of the Douglas bag method or the Cosmed K2 was randomly assigned. The results indicated that the Cosmed K2 instrument is reliable and valid (p > 0.05) for measurement of VO2 (l.min-1) during laboratory exercise testing at submaximum and maximum intensities. The assumption made by the K2 apparatus of a constant respiratory gas exchange ratio (R) of 1.00 did not have a significant influence on VO2 measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Individual variation in response to altitude training
Chapman, R. F., Stray-Gundersen, J., & Levine, B. D. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1448 · Cited by 283
Accuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
“While the reliability of the VO2000 for measuring VE is similar to other metabolic systems (Carter and Jeukendrup 2002; Larsson et al. 2004; Lucia et al. 1993; Meyer et al. 2001), the reliability for measuring VO2 and VCO2 is less than previously examined systems.”
BackgroundMethodAutomated Metabolic Gas Analysis Systems: A Review
Macfarlane, D. J. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00002 · Cited by 198
Validity and reliability of three commercially available breath-by-breath respiratory systems
Carter, J., & Jeukendrup, A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0572-2 · Cited by 169
“…that does exist concentrates largely upon portable systems, such as the Cosmed K2 telemetry system (Kawakami et al. 1992; Lothian et al. 1993; Lucia et al. 1993; Peel and Utsey 1993), the Cosmed K4 metabolic system (McLaughlin et al. 2001) and the Aerosport TEEM 100 portable J. Carter Æ A.E.…”
MethodTraining Effects of Accumulated Daily Stair-Climbing Exercise in Previously Sedentary Young Women
Boreham, C. A. G., Wallace, W. F. M., & Nevill, A. (2000) · Preventive Medicine · doi:10.1006/pmed.2000.0634 · Cited by 165
Pinnington, H. C., Wong, P., Tay, J., Green, D., & Dawson, B. (2001) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(01)80041-4 · Cited by 77
Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
(2020) · International Journal of Exercise Science · doi:10.70252/thjt1177 · Cited by 39
“96 for metabolic variables assessed with various COSMED models (5, 6, 14, 29).”
MethodLITTLEWOOD, R. (2002) · Clinical Nutrition · doi:10.1054/clnu.2002.0580 · Cited by 30
Metadata
- Authors
- Lucía, A., Fleck, S., Gotshall, R., & Kearney, J.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1993-10
- Volume
- 14
- Issue
- 07
- Pages
- 380-386
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2104641205
- Cited by
- 95
- References
- 0
- FWCI
- 15.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.