Validation of Aerosport KB1-C Portable Metabolic System
The DOI matches its Crossref record.
Abstract
The purpose of this study was to test the validity of the Aerosport KB1-C portable metabolic measurement system against the criterion Douglas bag method. During cycle ergometry, simultaneous measurements of minute ventilation (VE), oxygen consumption (VO2), and carbon dioxide production (VCO2) were made at rest and at power outputs of 50, 100, 150, 200, and 250 W. No significant differences (P > 0.05) were observed for VE, VO2, and VCO2 between the KB1-C and Douglas bag at 100, 150, and 250 W, while the KB1-C was significantly different (P < 0.05) from Douglas bag values at rest, 50, and 200 W. R values were found to be significantly different (P < 0.05) at 100, 150, and 200 W, while no significant differences were observed at rest, 50, and 250 W. The fractional concentrations of oxygen (FEO2) and carbon dioxide (FECO2) were not significantly different at 50, 100, 200, and 250 W while values at rest and 150 W were significantly different (P < 0.05). These findings show that the Aerosport KB1-C portable metabolic system is acceptable for measuring oxygen uptake in the range of 1.5 and 3.5 L x min(-1), using the medium flow pneumotach setting. At lower intensities, the low-flow pneumotach setting provides acceptable results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 513
Self-citationAccuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
Bassett, D. R., Howley, E. T., Thompson, D. L., King, G. A., Strath, S. J., McLaughlin, J. E., & Parr, B. B. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.218 · Cited by 118
Self-citationPaysant, J., Beyaert, C., Dati, A.-M., Martinet, N., & Andr, J.-M. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0043 · Cited by 68
“was expressed in mL O2/kg/min and O2C in mL O2/kg/m [37].”
Locomotor economy and the origin of bipedality: reply to Steudel-Numbers.
Leonard, W. R., & Robertson, M. L. (2001) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1111 · Cited by 9
Metadata
- Authors
- King, G., McLaughlin, J., Howley, E., Bassett, D., & Ainsworth, B.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 1999-07
- Volume
- 20
- Issue
- 05
- Pages
- 304-308
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2000097579
- Cited by
- 60
- References
- 0
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Aerosport KB1-C Portable Metabolic System. https://app.cochat.ai/papers/10.1055/s-2007-971135
- The paper
- King, G., McLaughlin, J., Howley, E., Bassett, D., & Ainsworth, B. (1999). Validation of Aerosport KB1-C Portable Metabolic System. International Journal of Sports Medicine. https://doi.org/10.1055/s-2007-971135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.