The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
Abstract
PURPOSE: This study was designed to establish prediction models that relate hip and wrist accelerometer data to energy expenditure (EE) in field and laboratory settings. We also sought to determine whether the addition of a wrist accelerometer would significantly improve the prediction of EE (METs), compared with a model that used a hip accelerometer alone. METHODS: Seventy participants completed one to six activities within the categories of yardwork, housework, family care, occupation, recreation, and conditioning, for a total of 5 to 12 participants tested per activity. EE was measured using the Cosmed K4b2 portable metabolic system. Simultaneously, two Computer Science and Applications, Inc. (CSA) accelerometers (model 7164), one worn on the wrist and one worn on the hip, recorded body movement. Correlations between EE measured by the Cosmed and the counts recorded by the CSA accelerometers were calculated, and regression equations were developed to predict EE from the CSA data. RESULTS: The wrist, hip, and combined hip and wrist regression equations accounted for 3.3%, 31.7%, and 34.3% of the variation in EE, respectively. The addition of the wrist accelerometer data to the hip accelerometer data to form a bivariate regression equation, although statistically significant (P = 0.002), resulted in only a minor improvement in prediction of EE. Cut points for 3 METs (574 hip counts), 6 METs (4945 hip counts), and 9 METs (9317 hip counts) were also established. CONCLUSION: The small amount of additional accuracy gained from the wrist accelerometer is offset by the extra time required to analyze the data and the cost of the accelerometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Research works printed but not linked: 14
- Bassett, 2000, Med Sci Sports Exerc, 32, S471, 10.1097/00005768-200009001-00006 · DOI · Paper page
- Hendelman, 2000, Med Sci Sports Exerc, 32, S442, 10.1097/00005768-200009001-00002 · DOI · Paper page
- Janz, 1994, Med Sci Sports Exerc, 26, 369, 10.1249/00005768-199403000-00015 · DOI · Paper page
- Janz, 1995, Cardiopul Phys Ther, 6, 3, 10.1097/01823246-199506020-00002 · DOI
- Janz, 1995, Med Sci Sports Exerc, 27, 1326
- Laporte, 1985, Public Health Rep, 100, 131
- McLaughlin, 1999, Int J Sports Med, 20, 304, 10.1055/s-2007-971135 · DOI
- Melanson, 1995, Med Sci Sports Exerc, 27, 934, 10.1249/00005768-199506000-00021 · DOI · Paper page
- Strath, 2000, Med Sci Sports Exerc, 32, S465, 10.1097/00005768-200009001-00005 · DOI · Paper page
- Thomas, 1992, Can J Sports Sci, 17, 338,
- Trost, 1998, Med Sci Sports Exerc, 30, 629, 10.1097/00005768-199804000-00023 · DOI · Paper page
- Tryon, 1996, Behav Res Meth Instr Comp, 28, 392, 10.3758/BF03200519 · DOI
- Washburn, 1997, Med Sci Sports Exerc, 30, S2,, 10.1097/00005768-199805001-00012 · DOI
- Welk, 2000, Med Sci Sports Exerc, 32, S489, 10.1097/00005768-200009001-00008 · DOI · Paper page
Cited by
International physical activity questionnaire: 12-country reliability and validity
CRAIG, C. L., MARSHALL, A. L., SJ??STR??M, M., BAUMAN, A. E., BOOTH, M. L., AINSWORTH, B. E., PRATT, M., EKELUND, U., YNGVE, A., SALLIS, J. F., et al. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078924.61453.fb · Cited by 21,619
Self-citationCompendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Self-citationLee, P. H., Macfarlane, D. J., Lam, T., & Stewart, S. M. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-115 · Cited by 3,370
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Metadata
- Authors
- SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2000-09
- Volume
- 32
- Issue
- Supplement
- Pages
- S450-S456
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2079462520
- Cited by
- 513
- References
- 2
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. https://app.cochat.ai/papers/10.1097/00005768-200009001-00003
- The paper
- SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000). Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200009001-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.