Exspiratorische Druckabsenkung (C-Flex) versus konstantem CPAP in der Therapie schlafbezogener obstruktiver Atemstörungen
The DOI matches its Crossref record.
Abstract
INTRODUCTION: The REM star C-Flex (Fa. Respironics) was introduced in 2003. In contrast to the conventionel fix CPAP mode, the C-Flex mode is characterised by a pressure reduction at the beginning of expiration. In a randomised cross-over design, we investigated if this C-Flex-mode has advantages compared to the fix CPAP mode in terms of treatment quality and patient satisfaction. METHODS: In this prospective randomised single-blinded cross-over study we investigated 20 patients with obstructive sleep apnoea treated with fix CPAP versus treatment with the C-Flex mode (level 2) for 6 weeks, respectively. We compared the polysomnographically measured quality of treatment and the subjective satisfaction of either form of therapy. Additionally, we measured long-term compliance of the C-Flex therapy in a 3-year follow-up with the integrated counter of the C-Flex devices. RESULTS: The mean levels of pressure of the fix CPAP and the C-Flex therapies were 8.4 +/- 2.9 mbar in both groups. There was an identical quality of treatment in terms of respiratory events, arousal index, slow wave sleep and Epworth sleepiness scale. The compliance of nocturnal use of the C-Flex and the fix CPAP was identical (6.0 +/- 0.67 C-Flex use vs. 5.8 +/- 0.98 CPAP use [h/night]). The subjective satisfaction was higher in the C-Flex mode at the end of the study since 18 of 20 patients (90%) subjectively prefered the C-Flex mode because of the easier expiration. 19 patients received a C-Flex device for long-term therapy. The 3-year-follow-up showed a regular utilisation of the C-Flex by 16 of 19 (84.2%) of these patients (mean nocturnal use 6.0 +/- 0.9 h/night). 3 of the 19 patients (15.8%) did not use their C-Flex regulary. None of the patients has terminated therapy completely. CONCLUSION: C-Flex mode and the conventional fix CPAP therapies show an equivalent treatment quality according to polysomnographic data. The expiratory pressure reduction compared to conventional CPAP was felt to be more comfortable by 90% of patients. The long-term-compliance as measured by regular use of the C-Flex device was 84.2% (16 out of 19 patients) after 3 years, these numbers are higher than published data on compliance with conventional CPAP therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Bakker, J., Campbell, A., & Neill, A. (2010) · Sleep · doi:10.1093/sleep/33.4.523 · Cited by 55
Kennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
Metadata
- Authors
- Wenzel, M., Kerl, J., Dellweg, D., Barchfeld, T., Wenzel, G., & Köhler, D.
- Venue
- Pneumologie
- Publisher
- Georg Thieme Verlag KG
- Published
- 2007-11
- Volume
- 61
- Issue
- 11
- Pages
- 692-695
- ISSN
- 0934-8387 (ISSN-L)
- 1438-8790
- OpenAlex
- W2409624677
- Cited by
- 20
- References
- 0
- FWCI
- 1.19
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exspiratorische Druckabsenkung (C-Flex) versus konstantem CPAP in der Therapie schlafbezogener obstruktiver Atemstörungen. https://app.cochat.ai/papers/10.1055/s-2007-980075
- The paper
- Wenzel, M., Kerl, J., Dellweg, D., Barchfeld, T., Wenzel, G., & Köhler, D. (2007). Exspiratorische Druckabsenkung (C-Flex) versus konstantem CPAP in der Therapie schlafbezogener obstruktiver Atemstörungen. Pneumologie. https://doi.org/10.1055/s-2007-980075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.