Continuous Glucose Monitoring in Cystic Fibrosis Patients According to the Glucose Tolerance
The DOI matches its Crossref record.
Abstract
Cystic fibrosis (CF) is associated with a long preclinical state of abnormal glucose tolerance. The aim of this study was (i) to evaluate the profile of glucose tolerance in young adults with CF and (ii) to compare these results with those obtained by a continuous subcutaneous glucose monitoring (CGMS). CF subjects with fasting glycemia inferior to 126 mg/dl were included in the study. An oral glucose tolerance test (OGTT) identified the subjects either with a normal glucose tolerance (NGT), or impaired glucose tolerance (IGT), or diabetes. CGMS (Medtronic) was performed during 3 days to analyze mean glucose level, high glucose excursions, and glucose area under the curve (AUC). Forty-nine patients were included in the study. NGT (n=22), IGT (n=17), and diabetes groups (n=10) were comparable except with regard to age and BMI (p<0.001). HbA1c values in diabetes group were significantly higher (p<0.001) than in NGT and IGT groups. CGMS revealed peaks of glucose values superior to 200 mg/dl at least once after a meal in 8 patients (36%) with NGT, in 9 patients (52%) with IGT, and in all patients with diabetes (p<0.01). Mean CGMS glucose and glucose AUC values increased in patients with diabetes compared to patients with NGT and IGT (p<0.05). Peak of CGMS glucose reached 182+/-60 mg/dl in NGT group despite the normal glucose profile at OGTT. In conclusion, CGMS revealed pathological glucose excursions not only in patients with impaired glucose tolerance at OGTT but also in patients with a normal glycemic profile. CGMS could be a useful tool for the early detection of hyperglycemia in patients with CF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Care Guidelines for Cystic Fibrosis–Related Diabetes
Moran, A., Brunzell, C., Cohen, R. C., Katz, M., Marshall, B. C., Onady, G., Robinson, K. A., Sabadosa, K. A., Stecenko, A., Slovis, B., et al. (2010) · Diabetes Care · doi:10.2337/dc10-1768 · Cited by 726
Epidemiology, Pathophysiology, and Prognostic Implications of Cystic Fibrosis–Related Diabetes
Moran, A., Becker, D., Casella, S. J., Gottlieb, P. A., Kirkman, M. S., Marshall, B. C., Slovis, B., & the CFRD Consensus Conference Committee (2010) · Diabetes Care · doi:10.2337/dc10-1279 · Cited by 258
Moran, A., Pillay, K., Becker, D., Granados, A., Hameed, S., & Acerini, C. L. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12732 · Cited by 171
Ode, K. L., Ballman, M., Battezzati, A., Brennan, A., Chan, C. L., Hameed, S., Ismail, H. M., Kelly, A., Moran, A. M., Rabasa‐Lhoret, R., et al. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13453 · Cited by 95
“Few individuals with CF have truly normal glucose tolerance (NGT) when compared to people without CF. 11,12 13-15 Early diabetes is characterized by normal fasting glucose levels, but over time fasting hyperglycemia develops.”
BackgroundNew insights into cystic fibrosis-related diabetes in children
Ode, K. L., & Moran, A. (2013) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(13)70015-9 · Cited by 76
Metadata
- Authors
- Moreau, F., Weiller, M., Rosner, V., Weiss, L., Hasselmann, M., Pinget, M., Kessler, R., & Kessler, L.
- Venue
- Hormone and Metabolic Research
- Publisher
- Georg Thieme Verlag KG
- Published
- 2008-07
- Volume
- 40
- Issue
- 07
- Pages
- 502-506
- ISSN
- 0018-5043 (ISSN-L)
- 1439-4286
- OpenAlex
- W2063255073
- Cited by
- 66
- References
- 0
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring in Cystic Fibrosis Patients According to the Glucose Tolerance. https://app.cochat.ai/papers/10.1055/s-2008-1062723
- The paper
- Moreau, F., Weiller, M., Rosner, V., Weiss, L., Hasselmann, M., Pinget, M., Kessler, R., & Kessler, L. (2008). Continuous Glucose Monitoring in Cystic Fibrosis Patients According to the Glucose Tolerance. Hormone and Metabolic Research. https://doi.org/10.1055/s-2008-1062723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.