Response of Ankle Systolic Pressure to Leg Exercise in Mild or Questionable Arterial Disease
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Measurement of ankle systolic pressure at rest is a valuable method for evaluation of patients with arterial disease. However, when disease is mild, pressure at rest may be normal. We measured ankle pressure, using a pneumatic cuff and an ultrasonic flow detector, before and after 2.5 minutes of flexion extension of the ankle at the rate of one per second. In 37 normal limbs ankle pressure after exercise either remained above or fell only a few millimeters of mercury below the brachial systolic pressure. In 14 limbs with mild disease, ankle pressure fell more than 16 mm Hg below brachial. Among 18 limbs with questionable disease, three responses were normal, four borderline (ankle pressure, 9 to 16 mm Hg below brachial), and 11 abnormal. Measurement of ankle systolic pressure after exercise is thus useful in the assessment of patients with mild or questionable arterial disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ankle systolic pressure measurements in arterial disease affecting the lower extremities
Yao, S. T., Hobbs, J. T., & Irivne, W. T. (1969) · Journal of British Surgery · doi:10.1002/bjs.1800560910 · Cited by 542
Indirect Systolic Pressures and Pulse Waves in Arterial Occlusive Disease of the Lower Extremities
CARTER, S. A. (1968) · Circulation · doi:10.1161/01.cir.37.4.624 · Cited by 308
Self-citationClinical Measurement of Systolic Pressures in Limbs With Arterial Occlusive Disease
Carter, S. A. (1969) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1969.03150230083009 · Cited by 257
Self-citationINFLUENCE OF ARTERIAL DISEASE ON THE SYSTOLIC BLOOD PRESSURE GRADIENTS OF THE EXTREMITY
Winsor, T. (1950) · The American Journal of the Medical Sciences · doi:10.1097/00000441-195008000-00001 · Cited by 216
Ds, S., & Strandness, D. E. (1969) · PubMed · Cited by 174
Use of Doppler Shift Detection for Determining Peripheral Arterial Blood Pressure
Thulesius, O., & Gjöres, J. E. (1971) · Angiology · doi:10.1177/000331977102201007 · Cited by 43
Cited by
Aboyans, V., Criqui, M. H., Abraham, P., Allison, M. A., Creager, M. A., Diehm, C., Fowkes, F. G. R., Hiatt, W. R., Jönsson, B., Lacroix, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276fbcb · Cited by 1,703
Conte, M. S., Pomposelli, F. B., Clair, D. G., Geraghty, P. J., McKinsey, J. F., Mills, J. L., Moneta, G. L., Murad, M. H., Powell, R. J., Reed, A. B., et al. (2015) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2014.12.009 · Cited by 921
Weitz, J. I., Byrne, J., Clagett, G. P., Farkouh, M. E., Porter, J. M., Sackett, D. L., Strandness, D. E., & Taylor, L. M. (1996) · Circulation · doi:10.1161/01.cir.94.11.3026 · Cited by 889
Hiatt, W. R., Hoag, S., & Hamman, R. F. (1995) · Circulation · doi:10.1161/01.cir.91.5.1472 · Cited by 551
The Clinical Utility of a Six‐Minute Walk Test in Peripheral Arterial Occlusive Disease Patients
Montgomery, P. S., & Gardner, A. W. (1998) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1998.tb03804.x · Cited by 390
Metadata
- Authors
- Carter, S. A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1972-09-21
- Volume
- 287
- Issue
- 12
- Pages
- 578-582
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2336831526
- Cited by
- 191
- References
- 6
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.