Increased Ionized Calcium and Left Ventricular Contractility during Hemodialysis
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Routine hemodialysis is associated with an increase in left ventricular contractility that is independent of a change in preload, but the mechanisms responsible are unknown. We investigated the importance of three distinct effects that regularly occur in hemodialysis and could potentially improve left ventricular contractility: the removal of uremic toxins, the increase in the plasma ionized calcium concentration, and the increase in the plasma bicarbonate concentration. Three different dialysates were used for each of eight stable patients on long-term hemodialysis, and left ventricular contractility was assessed by two-dimensional echocardiography before and after each dialysis. In the first procedure neither the ionized calcium nor the bicarbonate concentration was allowed to increase, and left ventricular contractility did not improve. In the second procedure, ionized calcium increased (from 4.4 to 5.4 mg per deciliter, P less than 0.001), bicarbonate concentration was held constant, and contractility increased (from 0.74 to 0.93 circumferences per second, P less than 0.005). In the third procedure, ionized calcium was kept constant, the bicarbonate concentration increased (from 19 to 24 mmol per liter, P less than 0.001), but contractility did not increase. These results suggest that the increase in ionized calcium that occurs in regular dialysis is a key factor in the improvement in left ventricular contractility observed during the procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,112
SCHEFFE, H. (1960) · Soil Science · doi:10.1097/00010694-196006000-00016 · Cited by 5,516
Teichholz, L. E., Kreulen, T., Herman, M. V., & Gorlin, R. (1976) · The American Journal of Cardiology · doi:10.1016/0002-9149(76)90491-4 · Cited by 2,571
Folland, E. D., Parisi, A. F., Moynihan, P. F., Jones, D. R., Feldman, C. L., & Tow, D. E. (1979) · Circulation · doi:10.1161/01.cir.60.4.760 · Cited by 726
A simplified radiometric assay for plasma norepinephrine and epinephrine
Passon, P. G., & Peuler, J. D. (1973) · Analytical Biochemistry · doi:10.1016/0003-2697(73)90517-4 · Cited by 637
Left ventricular volume from paired biplane two-dimensional echocardiography.
Schiller, N. B., Acquatella, H., Ports, T. A., Drew, D., Goerke, J., Ringertz, H., Silverman, N. H., Brundage, B., Botvinick, E. H., Boswell, R., et al. (1979) · Circulation · doi:10.1161/01.cir.60.3.547 · Cited by 610
The Elastic Symmetry of Arterial Segments in Dogs
PATEL, D. J., FRY, D. L., & Janicki, J. S. (1969) · Circulation Research · doi:10.1161/01.res.24.1.1 · Cited by 411
Estimation of right and left ventricular size by ultrasound
Popp, R. L., Wolfe, S. B., Hirata, T., & Feigenbaum, H. (1969) · The American Journal of Cardiology · doi:10.1016/0002-9149(69)90495-0 · Cited by 271
COOPER, R. H., O'ROURKE, R. A., KARLINER, J. S., PETERSON, K. L., & LEOPOLD, G. R. (1972) · Circulation · doi:10.1161/01.cir.46.5.914 · Cited by 225
Early cardiovascular adaptation to simulated zero gravity
Nixon, J. V., Murray, R. G., Bryant, C., Johnson, R. L., Mitchell, J. H., Holland, O. B., Gomez-Sanchez, C., Vergne-Marini, P., & Blomqvist, C. G. (1979) · Journal of Applied Physiology · doi:10.1152/jappl.1979.46.3.541 · Cited by 186
Self-citationEffects of changes of pH and of carbon dioxide tension on left ventricular performance
Ng, M., Levy, M., & Zieske, H. A. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.213.1.115 · Cited by 114
Reproducibility of Echocardiography
Pietro, D. A., Voelkel, A. G., Ray, B. J., & Parisi, A. F. (1981) · CHEST Journal · doi:10.1378/chest.79.1.29 · Cited by 75
Nixon, J. V. I., Anderson, R. J., & Cohen, M. L. (1979) · The American Journal of Medicine · doi:10.1016/0002-9343(79)90402-9 · Cited by 46
Self-citation
Cited by
K/DOQI Clinical Practice Guidelines for Cardiovascular Disease in Dialysis Patients
(2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.01.019 · Cited by 1,427
Dialysis hypotension: A hemodynamic analysis
Daugirdas, J. T. (1991) · Kidney International · doi:10.1038/ki.1991.28 · Cited by 334
London, G. M. (2003) · Seminars in Dialysis · doi:10.1046/j.1525-139x.2003.16023.x · Cited by 307
Silva, B. C., Freitas, G. R. R., Silva, V. B., Abensur, H., Luders, C., Pereira, B. J., de Oliveira, R. B., Castro, M. C. M., Moysés, R. M. A., & Elias, R. M. (2014) · Kidney and Blood Pressure Research · doi:10.1159/000368459 · Cited by 279
Hypocalcemia: A pervasive metabolic abnormality in the critically ill
Zivin, J. R., Gooley, T., Zager, R. A., & Ryan, M. J. (2001) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(01)80116-5 · Cited by 263
Metadata
- Authors
- Henrich, W. L., Hunt, J. M., & Nixon, J. V.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1984-01-05
- Volume
- 310
- Issue
- 1
- Pages
- 19-23
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2013220681
- Cited by
- 209
- References
- 13
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.