Ventilatory Support by Pacing of the Conditioned Diaphragm in Quadriplegia
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We provided full-time ventilatory support in five patients with respiratory paralysis accompanying quadriplegia by continuous electrical pacing of both hemidiaphragms simultaneously for 11 to 33 months through the application to the phrenic nerves of a low-frequency stimulus. The strength and endurance of the diaphragm muscle increased with pacing. Biopsy specimens taken from two patients who had uninterrupted stimulation for 6 and 16 weeks showed changes suggestive of the development of fatigue-resistant muscle fibers. When we compared these results with those of our earlier experience with intermittent unilateral stimulation of the diaphragm in 17 patients with respiratory paralysis, we found that continuous bilateral pacing using low-frequency stimulation appeared to be superior because of more efficient ventilation of both lungs, fewer total coulombs required to effect the same ventilation, and absence of myopathic changes in the diaphragm muscle. For patients with respiratory paralysis and intact phrenic nerves, continuous simultaneous pacing of both hemidiaphragms with low-frequency stimulation and a slow respiratory rate is a satisfactory method of providing full-time ventilatory support.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved technique for estimating pleural pressure from esophageal balloons
Milic-Emili, J., Mead, J., Turner, J. M., & Glauser, E. M. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.207 · Cited by 863
The influence of activity on some contractile characteristics of mammalian fast and slow muscles
Salmons, S., & Vrbová, G. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008771 · Cited by 722
Roussos, C. S., & Macklem, P. T. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.43.2.189 · Cited by 497
Ventilatory muscle strength and endurance training
Leith, D. E., & Bradley, M. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.4.508 · Cited by 396
Developmental pattern of muscle fiber types in human ventilatory muscles
Keens, T. G., Bryan, A. C., Levison, H., & Ianuzzo, C. D. (1978) · Journal of Applied Physiology · doi:10.1152/jappl.1978.44.6.909 · Cited by 324
The effect of training on strength and endurance of the diaphragm in quadriplegia
Gross, D., Ladd, H. W., Riley, E. J., Macklem, P. T., & Grassino, A. (1980) · The American Journal of Medicine · doi:10.1016/0002-9343(80)90157-6 · Cited by 203
Clinical Use of a Nomogram to Estimate Proper Ventilation during Artificial Respiration
Radford, E. P., Ferris, B. G., & Kriete, B. C. (1954) · New England Journal of Medicine · doi:10.1056/nejm195411252512201 · Cited by 190
Respiratory muscle fatigue after marathon running
Loke, J., Mahler, D. A., & Virgulto, J. A. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.52.4.821 · Cited by 145
Self-citationTotal Ventilatory Support in a Quadriplegic Patient with Radiofrequency Electrophrenic Respiration
Glenn, W. W. L., Holcomb, W. G., McLaughlin, A. J., O'Hare, J. M., Hogan, J. F., & Yasuda, R. (1972) · New England Journal of Medicine · doi:10.1056/nejm197203092861004 · Cited by 116
Self-citationVentilatory Support of the Quadriplegic Patient with Respiratory Paralysis by Diaphragm Pacing
Glenn, W. W. L., Hogan, J., & Phelps, M. L. (1980) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)42233-4 · Cited by 115
Self-citation
Cited by
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Respiratory Function during Pressure Support Ventilation
MacIntyre, N. R. (1986) · Chest · doi:10.1378/chest.89.5.677 · Cited by 415
Pulmonary function and spinal cord injury
Schilero, G. J., Spungen, A. M., Bauman, W. A., Radulovic, M., & Lesser, M. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.04.002 · Cited by 224
Long‐Term Follow‐Up of Pacing of the Conditioned Diaphragm in Quadriplegia
ELEFTERIADES, J. A., QUIN, J. A., HOGAN, J. F., HOLCOMB, W. G., LETSOU, G. V., CHLOSTA, W. F., & GLENN, W. W. W. L. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.00897.x · Cited by 79
“The remaining three patients were unable derive any support from pacing and were supported with mechanical ventilation.(2) The suboptimal results of full-time pacing in this early group of patients led to revision of the pacing protocol.”
BackgroundSelf-citation(1996) · PubMed · Cited by 79
Diaphragm Pacing for Respiratory Insufficiency
Chervin, R. D., & Guilleminault, C. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00003 · Cited by 56
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55
Metadata
- Authors
- Glenn, W. W. L., Hogan, J. F., Loke, J. S. O., Ciesielski, T. E., Phelps, M. L., & Rowedder, R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1984-05-03
- Volume
- 310
- Issue
- 18
- Pages
- 1150-1155
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2018728222
- Cited by
- 189
- References
- 14
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.