CoChat

Sonographic Identification of Second-Trimester Fetuses with Down's Syndrome

Benacerraf, Beryl R., Gelman, Rebecca, Frigoletto, Fredric D. · 1987 · New England Journal of Medicine
Cited by 317

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Fetuses with Down's syndrome are more likely than normal fetuses to have a thickened nuchal skin fold and relatively short femurs on ultrasound examination in the second trimester. We evaluated these measures in more than 5500 fetuses, including 28 who were later found to have Down's syndrome by means of amniocentesis with cytogenetic analysis. Normal femur length was established as a function of biparietal diameter in 192 of the normal fetuses. We found that with use of a nuchal skin-fold thickness of 6 mm or more and a ratio of actual to expected femur length of 0.91 or less, fetuses with Down's syndrome could be identified with a sensitivity of 75 percent and a specificity of 98 percent. When other anomalies, such as an atrioventricular canal and meconium peritonitis, were added to these two criteria, the sensitivity of sonographic detection of Down's syndrome in the second-trimester fetus rose to 82 percent. The potential predictive value of these sonographic signs far exceeds that of advanced maternal age and low alpha-fetoprotein levels, which currently identify only 10 to 30 percent of affected fetuses. We recommend that fetuses with a thickened nuchal skin fold or shortened femurs on ultrasound examination be evaluated for Down's syndrome by amniocentesis and cytogenetic analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm198711263172203

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 317

Metadata

Authors
Benacerraf, B. R., Gelman, R., & Frigoletto, F. D.
Venue
New England Journal of Medicine
Published
1987-11-26
Volume
317
Issue
22
Pages
1371-1376
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W1977259209
Cited by
317
References
7
FWCI
17.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.