Magnetic Resonance Imaging
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging (MRI) has become an essential tool for the diagnosis of central nervous system disorders and is used increasingly for the evaluation of a variety of diseases in other organ systems. The interpretation of magnetic resonance images is complex. In this time of cost containment in medicine, its high cost necessitates extra care in selecting appropriate clinical indications. In this article we shall review the basic principles, major clinical applications, and cost-benefit considerations in this rapidly changing field as well as upcoming developments.Physical PrinciplesMRI, or nuclear MRI, has its roots in the pioneering work of Bloch, . . .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Paramagnetic metal complexes as water proton relaxation agents for NMR imaging: theory and design
Lauffer, R. B. (1987) · Chemical Reviews · doi:10.1021/cr00081a003 · Cited by 1,978
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.69.127 · Cited by 883
Intracranial hematomas: imaging by high-field MR.
Gomori, J. M., Grossman, R. I., Goldberg, H. I., Zimmerman, R. A., & Bilaniuk, L. T. (1985) · Radiology · doi:10.1148/radiology.157.1.4034983 · Cited by 731
Blood Flow Imaging by Cine Magnetic Resonance
Nayler, G. L., Firmin, D. N., & Longmore, D. B. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198609000-00001 · Cited by 634
Awad, I. A., Spetzler, R. F., Hodak, J. A., Awad, C. A., & Carey, R. (1986) · Stroke · doi:10.1161/01.str.17.6.1084 · Cited by 587
Magnetic resonance imaging–based volume studies in temporal lobe epilepsy: Pathological correlations
Cascino, G. D., Jack, C. R., Parisi, J. E., Sharbrough, F. W., Hirschorn, K. A., Meyer, F. B., Marsh, W. R., & O'Brien, P. C. (1991) · Annals of Neurology · doi:10.1002/ana.410300107 · Cited by 482
A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
Bottomley, P. A., Hardy, C. J., Argersinger, R. E., & Allen‐Moore, G. (1987) · Medical Physics · doi:10.1118/1.596111 · Cited by 471
Jack, C. R., Sharbrough, F. W., Cascino, G. D., Hirschorn, K. A., O'Brien, P. C., & Marsh, W. R. (1992) · Annals of Neurology · doi:10.1002/ana.410310204 · Cited by 433
Cited by
Deep learning in bioinformatics
Min, S., Lee, B., & Yoon, S. (2016) · Briefings in Bioinformatics · doi:10.1093/bib/bbw068 · Cited by 1,465
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Evaluating and Managing Acute Low Back Pain in the Primary Care Setting
Atlas, S. J., & Deyo, R. A. (2001) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2001.91141.x · Cited by 296
Dong, Z., Feng, L., Zhu, W., Sun, X., Gao, M., Zhao, H., Chao, Y., & Liu, Z. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.09.025 · Cited by 284
Texaphyrins: Synthesis and Applications
Sessler, J. L., Hemmi, G., Mody, T. D., Murai, T., Burrell, A., & Young, S. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00038a002 · Cited by 260
Hiscox, L. V., Johnson, C. L., Barnhill, E., McGarry, M. D. J., Huston, J., van Beek, E. J. R., Starr, J. M., & Roberts, N. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/24/r401 · Cited by 230
“Conventional MRI applies a sequence of radiofrequency (RF) excitation pulses and phase and frequency encoding gradients to produce an image by encoding the spatial position of hydrogen nuclei (spins) in voxels within a tissue (Edelman and Warach 1993).”
BackgroundCarpenter, J. P., Holland, G. A., Baum, R. A., Owen, R. S., Carpenter, J. T., & Cope, C. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90325-g · Cited by 226
MR Imaging in Pelvic Inflammatory Disease: Comparison with Laparoscopy and US
Tukeva, T. A., Aronen, H. J., Karjalainen, P. T., Molander, P., Paavonen, T., & Paavonen, J. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja04209 · Cited by 221
Stochastic microstructure characterization and reconstruction via supervised learning
Bostanabad, R., Bui, A. T., Xie, W., Apley, D. W., & Chen, W. (2016) · Acta Materialia · doi:10.1016/j.actamat.2015.09.044 · Cited by 208
Skinner, M. P., Yuan, C., Mitsumori, L., Hayes, C. E., Raines M.P.S., E. W., Nelson, J. A., & Ross, R. (1995) · Nature Medicine · doi:10.1038/nm0195-69 · Cited by 203
Magnetic Resonance Angiography for the Diagnosis of Renal Artery Stenosis: A Meta-analysis
Tan, K. T., van Beek, E. J. R., Brown, P. W. G., van Delden, O. M., Tijssen, J., & Ramsay, L. E. (2002) · Clinical Radiology · doi:10.1053/crad.2002.0941 · Cited by 202
Nanoparticles and their potential for application in bone
Tautzenberger, A., Kovtun, & Ignatius (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s34127 · Cited by 180
“18 Thus, cell labeling provides the opportunity to visualize and track cell transport to the area of the defect in vivo and to assess the fate and participation of the transplanted cells in tissue regeneration.”
Imaging modalities to diagnose carotid artery stenosis: progress and prospect
Saxena, A., Ng, E. Y. K., & Lim, S. T. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0685-7 · Cited by 177
Stimulus-responsive liposomes as smart nanoplatforms for drug delivery applications
Zangabad, P. S., Mirkiani, S., Shahsavari, S., Masoudi, B., Masroor, M., Hamed, H., Jafari, Z., Taghipour, Y. D., Hashemi, H., Karimi, M., et al. (2018) · Nanotechnology Reviews · doi:10.1515/ntrev-2017-0154 · Cited by 163
Ghiassian, S., Greiner, R., Jin, P., & Brown, M. R. G. (2016) · PLOS ONE · doi:10.1371/journal.pone.0166934 · Cited by 116
“Here, we work toward improving automated diagnosis for mental illness using machine learning with structural magnetic resonance imaging (MRI) [3] and functional MRI [4] of the brain.”
Method
Metadata
- Authors
- Edelman, R. R., & Warach, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1993-03-11
- Volume
- 328
- Issue
- 10
- Pages
- 708-716
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2406361542
- Cited by
- 213
- References
- 26
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.