Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 319

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Performance of Four Computer-Based Diagnostic Systems

Berner, Eta S., Webster, George D., Shugerman, Alwyn A., Jackson, James R., Algina, James, Baker, Alfred L., Ball, Eugene V., Cobbs, C. Glenn, Dennis, Vincent W., Frenkel, Eugene P., Hudson, Leonard D., Mancall, Elliott L., Rackley, Charles E., Taunton, O. David·1994·New England Journal of Medicine

Abstract

BACKGROUND: Computer-based diagnostic systems are available commercially, but there has been limited evaluation of their performance. We assessed the diagnostic capabilities of four internal medicine diagnostic systems: Dxplain, Iliad, Meditel, and QMR. METHODS: Ten expert clinicians created a set of 105 diagnostically challenging clinical case summaries involving actual patients. Clinical data were entered into each program with the vocabulary provided by the program's developer. Each of the systems produced a ranked list of possible diagnoses for each patient, as did the group of experts. We calculated scores on several performance measures for each computer program. RESULTS: No single computer program scored better than the others on all performance measures. Among all cases and all programs, the proportion of correct diagnoses ranged from 0.52 to 0.71, and the mean proportion of relevant diagnoses ranged from 0.19 to 0.37. On average, less than half the diagnoses on the experts' original list of reasonable diagnoses were suggested by any of the programs. However, each program suggested an average of approximately two additional diagnoses per case that the experts found relevant but had not originally considered. CONCLUSIONS: The results provide a profile of the strengths and limitations of these computer programs. The programs should be used by physicians who can identify and use the relevant information and ignore the irrelevant information that can be produced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199406233302506

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 319

Metadata

Authors
Berner, E. S., Webster, G. D., Shugerman, A. A., Jackson, J. R., Algina, J., Baker, A. L., Ball, E. V., Cobbs, C. G., Dennis, V. W., Frenkel, E. P., Hudson, L. D., Mancall, E. L., Rackley, C. E., & Taunton, O. D.
Venue
New England Journal of Medicine
Published
1994-06-23
Volume
330
Issue
25
Pages
1792-1796
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2339530503
Cited by
319
References
40
FWCI
29.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of Four Computer-Based Diagnostic Systems. https://app.cochat.ai/papers/10.1056/nejm199406233302506
The paper
Berner, E. S., Webster, G. D., Shugerman, A. A., Jackson, J. R., Algina, J., Baker, A. L., Ball, E. V., Cobbs, C. G., Dennis, V. W., Frenkel, E. P., Hudson, L. D., Mancall, E. L., Rackley, C. E., & Taunton, O. D. (1994). Performance of Four Computer-Based Diagnostic Systems. New England Journal of Medicine. https://doi.org/10.1056/nejm199406233302506

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.