Performance of Four Computer-Based Diagnostic Systems
Abstract
BACKGROUND: Computer-based diagnostic systems are available commercially, but there has been limited evaluation of their performance. We assessed the diagnostic capabilities of four internal medicine diagnostic systems: Dxplain, Iliad, Meditel, and QMR. METHODS: Ten expert clinicians created a set of 105 diagnostically challenging clinical case summaries involving actual patients. Clinical data were entered into each program with the vocabulary provided by the program's developer. Each of the systems produced a ranked list of possible diagnoses for each patient, as did the group of experts. We calculated scores on several performance measures for each computer program. RESULTS: No single computer program scored better than the others on all performance measures. Among all cases and all programs, the proportion of correct diagnoses ranged from 0.52 to 0.71, and the mean proportion of relevant diagnoses ranged from 0.19 to 0.37. On average, less than half the diagnoses on the experts' original list of reasonable diagnoses were suggested by any of the programs. However, each program suggested an average of approximately two additional diagnoses per case that the experts found relevant but had not originally considered. CONCLUSIONS: The results provide a profile of the strengths and limitations of these computer programs. The programs should be used by physicians who can identify and use the relevant information and ignore the irrelevant information that can be produced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Users' guides to the medical literature
Guyatt, G. H. (1993) · JAMA · doi:10.1001/jama.270.17.2096 · Cited by 2,970
Internist-I, an Experimental Computer-Based Diagnostic Consultant for General Internal Medicine
Miller, R. A., Pople, H. E., & Myers, J. D. (1982) · New England Journal of Medicine · doi:10.1056/nejm198208193070803 · Cited by 1,127
Partners in Cognition: Extending Human Intelligence with Intelligent Technologies
SALOMON, G., PERKINS, D. N., & GLOBERSON, T. (1991) · Educational Researcher · doi:10.3102/0013189x020003002 · Cited by 948
Modified Sequentially Rejective Multiple Test Procedures
Shaffer, J. P. (1986) · Journal of the American Statistical Association · doi:10.1080/01621459.1986.10478341 · Cited by 806
Miller, R. A. (1994) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1994.95236141 · Cited by 458
Computer Programs to Support Clinical Decision Making
Shortliffe, E. H. (1987) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1987.03400010065029 · Cited by 331
Shwe, M., Blackford Middleton, A., Heckerman, D. E., Henrion, M., Horvitz, E., Lehmann, H. P., & Cooper, G. F. (1991) · PubMed · Cited by 293
DXplain: An Evolving Diagnostic Decision-Support System
Barnett, G. O. (1987) · JAMA · doi:10.1001/jama.1987.03400010071030 · Cited by 280
Medical Informatics: Computer Applications in Health Care.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-827_9 · Cited by 229
The INTERNIST-1/QUICK MEDICAL REFERENCE project--status report.
Miller, R. A., McNeil, M., Challinor, S. M., Masarie, F. E., & Myers, J. D. (1986) · PubMed Central · Cited by 191
Cited by
Artificial intelligence in healthcare
Yu, K.-H., Beam, A. L., & Kohane, I. S. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0305-z · Cited by 2,817
Overconfidence as a Cause of Diagnostic Error in Medicine
Berner, E. S., & Graber, M. L. (2008) · The American Journal of Medicine · doi:10.1016/j.amjmed.2008.01.001 · Cited by 1,034
Self-citationYang, G., Ye, Q., & Xia, J. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.07.016 · Cited by 717
Large Language Model Influence on Diagnostic Reasoning: A Randomized Clinical Trial
Goh, E., Gallo, R., Hom, J., Strong, E., Weng, Y., Kerman, H., Cool, J. A., Kanjee, Z., Parsons, A. S., Ahuja, N., et al. (2024) · JAMA Network Open · doi:10.1001/jamanetworkopen.2024.40969 · Cited by 724
Evaluating informatics applications – clinical decision support systems literature review
Kaplan, B. (2001) · International Journal of Medical Informatics · doi:10.1016/s1386-5056(01)00183-6 · Cited by 350
Metadata
- Authors
- Berner, E. S., Webster, G. D., Shugerman, A. A., Jackson, J. R., Algina, J., Baker, A. L., Ball, E. V., Cobbs, C. G., Dennis, V. W., Frenkel, E. P., Hudson, L. D., Mancall, E. L., Rackley, C. E., & Taunton, O. D.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1994-06-23
- Volume
- 330
- Issue
- 25
- Pages
- 1792-1796
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2339530503
- Cited by
- 319
- References
- 40
- FWCI
- 29.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of Four Computer-Based Diagnostic Systems. https://app.cochat.ai/papers/10.1056/nejm199406233302506
- The paper
- Berner, E. S., Webster, G. D., Shugerman, A. A., Jackson, J. R., Algina, J., Baker, A. L., Ball, E. V., Cobbs, C. G., Dennis, V. W., Frenkel, E. P., Hudson, L. D., Mancall, E. L., Rackley, C. E., & Taunton, O. D. (1994). Performance of Four Computer-Based Diagnostic Systems. New England Journal of Medicine. https://doi.org/10.1056/nejm199406233302506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.